HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 5-24 HP_SensorHardwareIndication: Fan Redundancy Reduced
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber
Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-7 Fan Redundancy Lost
Table 5-25 HP_SensorHardwareIndication: Fan Redundancy Lost
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
4 (Minor)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Cooling redundancy has been lost.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinCoolingRedundancySet.Caption
for the redundancy set that lost redundancy.
AlertingManagedElement
WBEM path of the HP_WinCoolingRedundancySet
instance representing the redundancy set where
redundancy was lost.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
6
ProviderName
HP Cooling
RecommendedActions
Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Cooling redundancy lost.
EventCategory
23 (System Cooling)