Table 5-23 Hp_SensorHardwareIndication: Fan Repaired
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber
Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-6 Fan Redundancy Reduced
Table 5-24 HP_SensorHardwareIndication: Fan Redundancy Reduced
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A fault tolerant fan is no longer providing cooling for a
cooling redundancy set. (RedundancySetCaption), where
RedundancySetCaption represents the
HP_WinCoolingRedundancySet.Caption for the
redundancy set with reduced redundancy.
AlertingManagedElement
WBEM path of the HP_WinCoolingRedundancySet
instance representing the redundancy set with reduced
redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
5
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Cooling redundancy reduced
EventCategory
23 (System Cooling)
ProbableCause
88 (Loss of Redundancy)