HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

HP Confidential
Table 5-18 Class: CIM_ElementCapacity
Property name
Property implementation
Capacity
References CIM_PhysicalCapacity
Element
References CIM_PhysicalElement
5-4 Supported indications
The following indications are implemented for ProLiant server platforms where available. System fan
indications are described in the following tables.
5-4-1 Fan Removed
Table 5-19 HP_SensorHardwareIndication: Fan Removed
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A fan has been removed (FanCaption), where
FanCaption is the HP_WinFan.Captionfan number that
was removed
AlertingManagedElement
WBEM path of the HP_WinCoolingCollection instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Cooling
RecommendedActions
Check the fan configuration and ensure that this fan
was removed intentionally.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Fan removed
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Fan Removed