HP Insight Management WBEM Providers 9.4 for Microsoft Windows Data Sheet

4-4 Supported indications
The following indications are implemented for ProLiant server platforms where available. System
power supply indications are described in the following tables.
4-4-1 Power Supply Removed
Table 4-24 HP_SensorHardwareIdentification: Power Supply Removed
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A power supply has been removed. (Power Supply n),
where n is the system power supply number that was
removed
AlertingManagedElement
WBEM path of the HP_WinPowerCollection instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Power
RecommendedActions
Check the system power supply configuration. Verify
that this power supply was removed intentionally.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Power supply removed
EventCategory
16 (System Power)
ProbableCause
1 (Other)
ProbableCauseDescription
Power Supply Removed
ProviderVersion
Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses
Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication