HP Insight Management WBEM Providers 9.
Legal notices © Copyright 2008, 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP will not be liable for technical or editorial errors or omissions contained herein. Confidential computer software.
Contents 1 2 Overview ................................................................................................................................ 19 Base server .............................................................................................................................. 20 Overview ............................................................................................................................. 20 Use cases ...................................................................
3-3-11 3-3-12 3-3-13 3-3-14 3-3-15 3-3-16 3-3-17 3-3-18 3-4 3-4-1 3-4-2 4 HP_ProcessorCollection ............................................................................................... 72 HP_ProcessorGroupHostedCollection ............................................................................ 73 HP_PhysicalMemberOfProcessorCollection .................................................................... 74 HP_ProcessorChip ........................................................................
-3-3 5-3-4 5-3-5 5-3-6 5-3-7 5-3-8 5-3-9 5-3-10 5-3-11 5-3-12 5-3-13 5-3-14 5-3-15 5-3-16 5-3-17 5-4 5-4-1 5-4-2 5-4-3 5-4-4 5-4-5 5-4-6 5-4-7 5-4-8 5-4-9 6 HP_CoolingRedundancySet.................................................................................................. 122 HP_MemberOfCoolingRedundancy ...................................................................................... 123 HP_HostedCoolingRedundancySet ............................................................................
7-4-9 7-4-10 7-4-11 7-4-12 7-4-13 7-4-14 7-4-15 7-4-16 7-4-17 7-4-18 7-4-19 7-4-20 7-4-21 7-4-22 7-5 7-5-1 7-5-2 7-5-3 7-5-4 8 HP_MemberOfMemoryRedundancySet ................................................................................. 176 HP_HostedMemoryRedundancySet ............................................................................. 177 HP_RealizesMemoryModule ...................................................................................... 177 HP_MemoryModuleSlot ....................
10-3-2 10-3-3 10-3-4 10-4 11 HP_CommonLogEntry ................................................................................................ 222 HP_LogManagesRecord ............................................................................................ 223 HP_UseOfLog ........................................................................................................... 224 Supported indications ...................................................................................................
13-3-21 13-3-22 13-3-23 13-4 13-4-1 13-4-2 13-4-3 13-4-4 13-4-5 13-4-6 13-4-7 13-4-8 13-4-9 13-4-10 13-4-11 13-4-12 13-4-13 13-4-14 13-4-15 14 HP_Location ............................................................................................................. 253 HP_ElementLocation .................................................................................................. 254 HP_EthEventSettings ..................................................................................................
15-3-23 15-3-24 15-3-25 15-3-26 15-3-27 15-3-28 15-3-29 15-3-30 15-3-31 15-3-32 15-3-33 15-3-34 15-3-35 15-3-36 15-3-37 15-3-38 15-3-39 15-3-40 15-3-41 15-3-42 15-3-43 15-3-44 15-3-45 15-3-46 15-3-47 15-3-48 15-3-49 15-3-50 15-3-51 15-3-52 15-3-53 15-3-54 15-3-55 15-3-56 15-3-57 15-3-58 15-3-59 15-3-60 15-3-61 15-3-62 15-3-63 15-3-64 15-3-65 15-3-66 15-3-67 15-3-68 15-3-69 15-3-70 15-3-71 15-3-72 15-3-73 15-3-74 15-3-75 15-3-76 HPSA_SCSIProtocolController ...................................................
15-3-77 HPSA_PrimordialPoolStoragePool (Association)............................................................ 341 15-3-78 HPSA_SpareExtentStorageExtent (Association) ............................................................. 341 15-3-79 HPSA_SpareExtentStorageRedundancySet (Association) ............................................... 341 15-3-80 HPSA_StorageExtentStorageVolume (Association) ........................................................
15-4-21 15-4-22 15-4-23 15-4-24 15-4-25 15-4-26 15-4-27 15-4-28 15-4-29 15-4-30 15-4-31 15-4-32 15-4-33 15-4-34 15-4-35 15-4-36 16 Controller Battery Status Changed to OK .................................................................... 397 Controller Battery Status Changed to not fully charged ................................................. 399 Controller Battery Status Changed to FAILED ............................................................... 402 Controller Cache Status Changed to OK .......
16-3-34 HPSAS_StorageEnclosureStorageEnclosureProcessor (Association) ................................. 459 16-3-35 HPSAS_StorageVolumeStorageSetting (Association) ..................................................... 460 16-3-36 HPSAS_PrimordialPoolStorageCapabilities (Association) ............................................... 460 16-3-37 HPSAS_PrimordialPoolNoRaidStorageCapabilities (Association) .................................... 460 16-3-38 HPSAS_StoragePoolStorageCapabilities (Association) ........
2-4-12 2-4-13 2-4-14 2-4-15 2-4-16 2-4-17 2-4-18 2-4-19 2-4-20 17 Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Power Supply status changed to Non Redundant ..................................................... 495 Power Supply Status changed to OK (Redundant) .................................................... 497 Power Supply Status changed to Redundant Degraded ............................................ 500 Temperature sensor Status changed to OK ........
17-3-41 17-3-42 17-3-43 17-3-44 17-3-45 17-3-46 17-3-47 17-3-48 17-3-49 17-3-50 17-3-51 17-3-52 17-3-53 17-3-54 17-3-55 17-3-56 17-3-57 17-3-58 17-3-59 17-3-60 17-4 17-4-1 17-4-2 17-4-3 17-4-4 17-4-5 17-4-6 17-4-7 17-4-8 17-4-9 17-4-10 17-4-11 17-4-12 17-4-13 17-4-14 17-4-15 17-4-16 17-4-17 17-4-18 17-4-19 17-4-20 18 HPSCSI_SCSIProtocolControllerStorageVolume (Association) ......................................... 541 HPSCSI_StorageEnclosureProcessorEnclosureFirmware (Association) ........................
18-3-7 18-3-8 18-3-9 18-3-10 18-3-11 18-3-12 18-3-13 18-3-14 18-3-15 18-3-16 18-3-17 18-3-18 18-3-19 18-3-20 18-3-21 18-3-22 18-3-23 18-3-24 18-3-25 18-3-26 18-3-27 18-3-28 18-3-29 18-3-30 18-3-31 18-3-32 18-3-33 18-3-34 18-3-35 18-4 18-4-1 18-4-2 18-4-3 18-4-4 18-4-5 18-4-6 18-4-7 18-4-8 19 20 HPFCHBA_Product .................................................................................................... 601 HPFCHBA_SoftwareIdentityDrv ................................................................
20-4 21 Supported indications ......................................................................................................... 641 Standalone tape drive ........................................................................................................ 642 Overview ........................................................................................................................... 642 Use cases ...........................................................................................
22-3-7 22-3-8 22-3-9 22-3-10 23 HPHDR_ComputerSystemRemoteServiceAccessPoint (Association) .................................. 682 HPHDR_ComputerSystemLogicalDisk (Association) ....................................................... 683 HPHDR_ComputerSystemSCSIProtocolEndpointInitiator (Association) .............................. 683 HPHDR_ComputerSystemSCSIProtocolEndpointTarget (Association) ................................ 683 Host attached SATA .........................................................
23-5 24 For more information ........................................................................................................... 719 BIOS Management ............................................................................................................. 720 Overview ........................................................................................................................... 720 Use cases ...........................................................................................
1 Overview The HP Insight Management WBEM Providers supply system management data through the Windows® Management Instrumentation (WMI) framework for HP ProLiant server platforms and options. These providers implement the profiles and data described in this document. Use of the providers requires Windows Server® 2008, Windows Server® 2012, and WMI.
2 Base server 2-1 Overview The following profiles are implemented, and files are installed by this provider. Table 2-1 Overview Implemented Profiles Provider Installation Files 2-2 HP Base Server Profile (P00105) HPWmiSys.dll HP Base Server Physical Asset Profile (P00114) DMTF Power State Management Profile (DSP1027) DMTF Software Inventory Profile (DSP1023) HPWmiSysEvt.dll HPWmiSysEvtMsg.dll HPWmiSys.
Table 2-2 Class: HP_WinComputerSystem Properties ElementName Computer system DNS name returned by Windows API GetComputerSystemName() CIM_ManagedSystemElement OperationalStatus OperationalStatus[0] contains the computer system consolidated status and indicates the worst status of connected subsystems.
Table 2-2 Class: HP_WinComputerSystem Properties OtherIdentifyingInfo OtherIdentifyingInfo[0]: where is HP_ComputerSystemChassis.ProductID. OtherIdentifyingInfo[1]: where is the computer system GUID string. OtherIdentifyingInfo[2]: : where is the computer system model string and is the computer system serial number string.
Table 2-2 Class: HP_WinComputerSystem Properties PrimaryOwnerPager Computer system primary owner pager string; initialized to an empty string (――) (writable property; persistent across reboots) SecondaryOwnerContact Computer system secondary owner contact string; initialized to an empty string (――) (writable property; persistent across reboots) SecondaryOwnerName Computer system secondary owner name string; initialized to an empty string (――) (writable property; persistent across reboots) SecondaryOwn
Table 2-3 Class: HP_ComputerSystemChassis Property name Property implementation CIM_PhysicalElement Tag Concatenation of serial number string and product ID string CreationClassName HP_ComputerSystemChassis ElementName Computer system product name (model) string Manufacturer Computer manufacturer string Model Computer system product name (model) string SerialNumber Computer system serial number string UserTracking Computer system asset tag string (read only property; persistent across reboots
2-3-3 HP_ComputerSystemPackage HP_ComputerSystemPackage extends the class CIM_ComputerSystemPackage and associates instances of HP_ComputerSystem and HP_ComputerSystemChassis. Only one instance of HP_ComputerSystemPackage is instantiated on a ProLiant server. The following properties are implemented.
Table 2-5 Class: HP_PowerManagementService Properties Property name Property implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_Service SystemName Computer system DNS name returned by Windows API GetComputerSystemName() Started true SystemCreationClassName HP_WinComputerSystem Name Server Power Management Service CreationClassName HP_PowerManagementService CIM_PowerManagmentService HP_PowerManagmentService Table 2-6 Implemented
Table 2-7 Class: HP_PowerManagementCapabilities Properties Property name Property implementation CIM_ManagedElement Caption Power Management Capabilities Description Power Management Capabilities CIM_Capabilities ElementName Power Capabilities 1 InstanceID Power Capabilities 1 CIM_PowerManagmentCapabilities PowerCapabilities PowerCapabilities[0]: 3 (Power State Settable) PowerCapabilities[1]: 4 (Power Cycling Supported) PowerChangeCapabilities PowerChangeCapabilities[0]: 3 (Power State Se
2-3-7 HP_PowerManagementElementCapabilities HP_PowerManagementElementCapabilities extends the class CIM_ElementCapabilities and associates the HP_PowerManagementService instance and the HP_PowerManagementCapabilities instance. Only one instance of HP_PowerManagementElementCapabilities is instantiated on a ProLiant server. The following properties are implemented.
Table 2-11 Class: HP_SystemROMFirmware Property name Property implementation CIM_ManagedElement Caption System ROM Firmware- (), where is the system ROM family code and is either Active or Redundant Examples: System ROM Firmware-P31 (Active) System ROM Firmware-P31 (Redundant) Description System ROM Firmware- (), where is the system ROM family code and is either Active or Redundant Examples: System ROM Firmware-P
Table 2-11 Class: HP_SystemROMFirmware Property name Property implementation Manufacturer HP/Hewlett-Packard Classifications 11 (Bios/FCode) ClassificationDescriptions System ROM Firmware IdentityInfoValue HPQ: where is the system ROM family code (for example, HPQ:P31). IdentityInfoType CIM:SoftwareFamily ReleaseDate YYYYMMDD******.
2-3-11 HP_SystemROMInstalledFirmwareIdentity HP_SystemROMInstalledFirmwareIdentity extends the class CIM_InstalledSoftwareIdentity and associates the HP_ComputerSystem instance and an HP_SystemROMFirmware instance. The following properties are implemented.
Table 2-14 Class: HP_SystemXNCFirmware Property name Property implementation ElementName Examples: SPI board cPLD firmware Main IO CPLD Firmware Upper CPU board CPLD Firmware Lower CPU board CPLD Firmware Upper FMP Firmware Lower FMP firmware Upper FPGA Firmware Lower FPGA Firmware Small form factor IO board cPLD Firmware PCIe subIO CPLD Firmware Combo PCIe/PCI-X SubIO CPLD Firmware Note: Either PCIe or Combo PCIe/PCI-X component instance will be ava
Table 2-14 Class: HP_SystemXNCFirmware Property name Property implementation InstanceID HPQ: HP_SystemXNCFirmware:, where is number assigned to the XNC firmware component Examples: HPQ: HP_SystemXNCFirmware:1 represents SPI board cPLD firmware HPQ: HP_SystemXNCFirmware:2 represents Main IO CPLD firmware HPQ: HP_SystemXNCFirmware:3 represents Upper CPU board CPLD firmware HPQ: HP_SystemXNCFirmware:4 represents Lower CPU board CPLD firmware HPQ: HP_SystemXNCFirmware:5 represents Upper
Table 2-14 Class: HP_SystemXNCFirmware Property name Property implementation IdentityInfoValue HPQ: Examples: HPQ: CPLD-P66-SPI HPQ: CPLD-P66-MAINIO HPQ: CPLD-P66-UPPERCPU HPQ: CPLD-P66-LOWERCPU HPQ: FMP-P66-UPPERXNC HPQ: FMP-P66-LOWERXNC HPQ: CPLD-P66-UPPERXNCFPGA HPQ: CPLD-P66-LOWERXNCFPGA HPQ: CPLD-P66-SFF HPQ: CPLD-P66-PCIEIO HPQ: CPLD-P66-PCIEXIO Note: Either PCIe or Combo PCIe/PCI-X component instance will be available at a time on the
The following properties are implemented. Table 2-16 Class: HP_SystemXNCInstalledFirmwareIdentity Property name Property implementation CIM_InstalledSoftwareIdentity HP_SystemXNCInstalledFirmwareIdentity 2-4 InstalledSoftware ref: HP_SystemXNCFirmware System ref: HP_ComputerSystem Supported indications The following indications are implemented for ProLiant server platforms where available. System indications are described in the following tables.
Table 2-17 HP_SystemHardwareIndication: ASR Reboot Occurred Property name Property implementation ProbableCause 111 (Timeout) ProbableCauseDescription ASR Reboot Occurred ProviderVersion Provider version generating the indication in the format, ...
Table 2-17 HP_SystemHardwareIndication: ASR Reboot Occurred 2-4-2 Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Table 2-18 HP_SystemHardwareIndication: Thermal Reboot Occurred Property name Property implementation NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format
2-4-3 POST Error Occurred Table 2-19 HP_SystemHardwareIndication: POST Error Occurred Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description Power-On-Self-Test errors occurred during the last system startup AlertingElementFormat 1 (Unknown) AlertType 5 (Device Alert) EventID 1 ProviderName HP POST RecommendedActions Check the Power-On Self-Test (POST) Erro
Table 2-19 HP_SystemHardwareIndication: POST Error Occurred Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames VariableNames[0]: POST Error Code VariableNames[1]: POST Error String VariableTy
Table 2-20 HP_SystemHardwareIndication: WBEM Providers Started Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description HP Insight Management WBEM Providers have started AlertType 5 (Device Alert) EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP WBEM RecommendedActions No
Table 2-20 HP_SystemHardwareIndication: WBEM Providers Started Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
Table 2-21 HP_SystemHardwareIndication: DL980 System Providers Started Property name Property implementation CIM_AlertIndication Description Reporting Entity: McHealthProvider Service Event Timestamp: Where is the date and time of the indication AlertType 5 (Device Alert) EventID 8001 EventTime Time of the event or time of the indication if event time unknown ProviderName HP MCHealth RecommendedActions No action is recommended. SystemName HP_ComputerSystem.
Table 2-21 HP_SystemHardwareIndication: DL980 System Providers Started Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.
Table 2-22 HP_SystemHardwareIndication: DL980 System configuration (current 40-bit addressing mode) is not optimal Property name Property implementation CIM_AlertIndication Description The system is not configured for optimal performance as its address mode is currently set to 40bit instead of the Windows recommended 44-bit mode. In addition to the larger addressable physical address space, the 44-bit mode improves the system performance by generating less address decoding faults.
Table 2-22 HP_SystemHardwareIndication: DL980 System configuration (current 40-bit addressing mode) is not optimal Property name Property implementation OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion The operating system version of the computer system generating the indication in the following format: ..
DL980 System configuration (current 44-bit addressing mode) is not optimal 2-4-7 Note: This indication is specific to DL980 servers. These events will not log messages in Windows Event log.
Table 2-23 HP_SystemHardwareIndication: DL980 System configuration (current 44-bit addressing mode) is not optimal Property name Property implementation OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion The operating system version of the computer system generating the indication in the following format: ..
DL980 System configuration (current hyper-threading mode enabled) is not optimal 2-4-8 Note: This indication is specific to DL980 servers. These events will not log messages in Windows Event log.
Table 2-24 HP_SystemHardwareIndication: DL980 System configuration (current hyper-threading mode enabled) is not optimal Property name Property implementation NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion The operating system version of th
Table 2-24 HP_SystemHardwareIndication: DL980 System configuration (current hyper-threading mode enabled) is not optimal Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v.. DL980 System configuration (current hyper-threading mode disabled) is not optimal 2-4-9 Note: This indication is specific to DL980 servers.
Table 2-25 HP_SystemHardwareIndication: DL980 System configuration (current hyper-threading mode disabled) is not optimal Property name Property implementation EventCategory 1 (Other) ProbableCause 1 (Other) ProbableCauseDescription ProviderVersion Provider version generating the indication in the format, ...
Table 2-25 HP_SystemHardwareIndication: DL980 System configuration (current hyper-threading mode disabled) is not optimal Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment CIM_ThresholdIndication ThresholdValue A string holding the current value of the warning threshold ObservedValue A string holding the current reading value that exceeds the threshold HP_Thresh
Table 2-15 HP_ThresholdIndication: Average CPU Utilization critical threshold exceeded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description The Average CPU utilization critical threshold has exceeded for CPU :(CPU Name) AlertingElementFormat 1 (Unknown) AlertType 1 0x1 (Other) EventID 1 ProviderName HP CPU Threshold RecommendedActions None
For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format .. ProviderVersion Provider version generating the indication in the format, ...
indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Threshold Indication - Disk Utilization Critical Threshold Exceeded 2-4-13 Table 2-15 HP_ThresholdIndication: Disk Utilization Critical Threshold Exceeded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description The Disk utilization critical threshold has exceeded for Disk:(Disk Name) AlertingElementFormat 1 (Unknown) AlertType 1 0x1 (Other) EventI
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format ..
3 CPU 3-1 Overview The following profiles are implemented, and the following files are installed by this provider. Table 3-1 Overview Implemented Profiles HP CPU Consolidated Status Profile (P00107) HP CPU Physical Asset Profile (P00108) HP Location Profile (P00124) HPWmiProc.dll HPWmiProcEvt.dll HPWmiProcEvtMsg.
Table 3-2 Class: HP_Processor Properties Property name Property implementation Description (x86 Family x Model y Stepping z), where is the processor brand string, x is the processor Extended family number, y is the processor Extended Model number and z is the processor stepping number Example: Intel(R) Xeon(TM) CPU 3.
Table 3-2 Class: HP_Processor Properties Property name Property implementation CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice SystemCreationClassName HP_WinComputerSystem SystemName Computer system name from Windows API GetComputerSystemName() CreationClassName HP_Processor DeviceID Proc n, where n is the processor number CIM_Processor CPUStatus 1 (CPU Enabled) 2 (CPU Disabled by User using BIOS Set
3-3-2 HP_ProcessorCapabilities HP_ProcessorCapabilities extends the class CIM_ProcessorCapabilities to model the processor capabilities. The following properties are implemented.
Table 3-4 Class: HP_ProcessorCore Property name Property implementation CIM_ManagedElement Caption Processor p - Core c, where p is the processor number and c is the core number Description (x86 Family x Model y Stepping z) (Processor p - Core c), where is the processor brand string, x is the processor family number, y is the processor Exended.
Table 3-4 Class: HP_ProcessorCore Property name Property implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) 3 (Disabled) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_ProcessorCore InstanceID HPQ:HP_ProcessorCore:n, where n is a unique, sequentially-assigned number in the form 001, 002, and so on.
Table 3-5 Class: HP_HardwareThread Property name Property implementation Description (x86 Family x Model y Stepping z) (Processor p - Core c - Thread t), where is the processor brand string, x is the processor Extended family number, y is the processor Extended Model number, z is the processor stepping number, p is the processor number, c is the core number, and t is the thread number Example: Intel(R) Xeon(TM) CPU 3.
Table 3-5 Class: HP_HardwareThread Property name Property implementation EnabledState 2 (Enabled) 3 (Disabled) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_HardwareThread InstanceID HPQ:HP_HardwareThread:n, where n is a unique, sequentially-assigned number in the form 001, 002, and so on. HP_HardwareThread 3-3-5 HP_ProcessorCacheMemory HP_ProcessorCacheMemory implements the class HP_CacheMemory, which extends CIM_Memory to model the processor caches.
Table 3-6 Class: HP_ProcessorcacheMemory Property name Property implementation ElementName One of the following: Level x Data Cache, where x is the cache level number Level x Instruction Cache, where x is the cache level number Level x Unified Cache, where x is the cache level number Examples: Level 1 Data Cache Level 2 Unified Cache CIM_ManagedSystemElement OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is
Table 3-6 Class: HP_ProcessorcacheMemory Property name Property implementation CIM_LogicalDevice SystemCreationClassName HP_WinComputerSystem SystemName Computer system name from Windows API GetComputerSystemName() CreationClassName HP_ProcessorCacheMemory DeviceID One of the following: Proc p, Level x Cache, where p is the processor number, x is the cache level number, and is the cache type (Data, Instruction, or Unified) Proc p, Core c, Level x Cache, where p is the pro
Table 3-7 Class: HP_SystemProcessor Property name Property implementation HP_SystemProcessor 3-3-7 GroupComponent ref: HP_ComputerSystem PartComponent ref: HP_Processor HP_ProcessorElementCapabilities HP_ProcessorElementCapabilities extends the class CIM_ElementCapabilities and associates HP_Processor and HP_ProcessorCapabilities instances. The following properties are implemented.
The following properties are implemented. Table 3-10 Class: HP_HWThreadComponent Property name Property implementation CIM_Component CIM_ConcreteComponent HP_HWThreadComponent 3-3-10 GroupComponent ref: HP_ProcessorCore PartComponent ref: HP_HardwareThread HP_AssociatedCacheMemory HP_AssociatedCacheMemory extends the class CIM_AssociatedCacheMemory. The ProLiant implementation class is HP_AssociatedProcessorCacheMemory.
Table 3-11 Class: HP_AssociatedProcessorCacheMemory Property name Property implementation Line Size Cache line size in bytes Read Policy 0 (Unknown) 0 (Unknown) Associativity 1 (Other) 2 (Read) 3 (Read-Ahead) 4 (Read and Read-Ahead) 5 (Determination Per I/O) 1 (Other) 2 (Direct Mapped) 3 (2-way Set-Associative) 4 (4-way Set-Associative) 5 (Fully Associative) 6 (8-way Set-Associative) 7 (16-way Set-Associative) HP_AssociatedCacheMemory Antecedent ref: HP_CacheMemory
Table 3-12 Class: HP_ProcessorCollection Property name Property implementation GroupOperationalStatus GroupStatusDescriptions 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) 5 (Predictive Failure) 6 (Error) 10 (Stopped) GroupStatusDescriptions[0] text per GroupOperationalStatus[0]: Aggregate Processor Package status unknown Aggregate Processor Package status other Aggregate Processor Package status OK Aggregate Processor Package status degraded Aggregate Processor Package status pr
3-3-13 HP_PhysicalMemberOfProcessorCollection HP_PhysicalMemberOfProcessorCollection extends the class CIM_MemberOfCollection and associates the HP_ProcessorCollection instance with an HP_ProcessorChip instance. The following properties are implemented.
Table 3-15 Class: HP_ProcessorChip Properties Property name Property implementation StatusDescriptions StatusDescriptions[0] text per OperationalStatus[0]: Processor-module status unknown.
Table 3-15 Class: HP_ProcessorChip Properties Property name Property implementation Version Model y Stepping z, where y is the processor Extended Model number, and z is the processor stepping number PoweredOn 0 (False)—If CPU is disabled through RBSU or POST error 1 (True)—If CPU is enabled 0 (False) 1 (True) CanBeFRUed CIM_PhysicalComponent RemovalConditions 3 (Removable When Off) CIM_Chip HP_ProcessorChip ProcessorChipRevision 3-3-15 Stepping z, where z is the processor stepping number
Table 3-17 Class: HP_SystemPhysicalProcessor Property name Property implementation CIM_Component CIM_Container HP_SystemPhysicalProcessor 3-3-17 GroupComponent ref: HP_ComputerSystemChassis PartComponent ref: HP_ProcessorChip HP_ProcessorLocation HP_ProcessorLocation implements the class HP_Location that extends the class CIM_Location. For ProLiant systems, processor location is denoted by the use of a slot number designator and a socket number designator.
Table 3-18 Class: HP_ProcessorLocation Property name Property implementation Name Processor in slot a, where a is the slot number Processor in socket b, where b is the socket number Processor in slot a socket b, where a is the slot number and b is the socket number a, where a is the slot number (when no socket PhysicalPosition number exists) b, where b is the socket number (when no slot number exists) a:b, where a is the slot number and b is the socket number HP_Location a, where a is
Table 3-19 Class: HP_ProcessorElementLocation Property name Property implementation HP_ProcessorElementLocation 3-4 Element ref: HP_ProcessorChip PhysicalLocation ref: HP_ProcessorLocation Supported indications The following indications are implemented for ProLiant server platforms where available. CPU indications are described in the following table.
Table 3-20 HP_ProcessorHardwareIndication: Processor Failed Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
Table 3-20 HP_ProcessorHardwareIndication: Processor Failed 3-4-2 Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Table 3-21 HP_ProcessorHardwareIndication: Processor Deconfigured Property name Property implementation NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion The operating system version of the computer system generating the indication in the follo
4 System power supply 4-1 Overview This provider implements the HP Power Supply profile to model power supplies in ProLiant systems. The following profiles are implemented, and the following files are installed by this provider. Table 4-1 Overview 4-2 Implemented Profiles HP Power Supply Profile 1.0 HP Power Supply Physical Asset Profile 1.0 HP Location Profile 1.0 Provider Installation Files HPWmiSensor.DLL HPWmiSensorEvt.DLL HPWmiSensorEvtMsg.DLL HPWmiSensor.
Table 4-2 Class: HP_PowerSupply Property name Property implementation CIM_ManagedElement Caption Power Supply n, where n represents the number of the power supply instances. Description Power Supply n provides power for system. StatusDescription, where n represents the number of the power supply instance and StatusDescription represents the value of StatusDescriptions[0] ElementName Power Supply n, where n represents the number of the power supply instances.
Table 4-2 Class: HP_PowerSupply Property name Property implementation OperationalStatus[1..n] Additional operational status values may be exposed in array elements greater than 0 depending on the power supply capabilities.
Table 4-2 Class: HP_PowerSupply Property name Property implementation StatusDescriptions[0] Power Supply is operating properly—If OperationalStatus[0] is 2 (OK) Power Supply has failed—If OperationalStatus is 6 (Error)
Table 4-2 Class: HP_PowerSupply Property name Property implementation StatusDescriptions[1..n] Additional status description values may be exposed in array elements greater than 0 depending on the power supply capabilities. Operational status element 0 will aggregate any additional values Power supply in error state due to failure — If OperationalStatus[1..n] is 32768 (Power supply error detected failure) Power supply in error state due to over voltage — If OperationalStatus[1..
Table 4-2 Class: HP_PowerSupply Property name Property implementation Name Power Supply n, where n represents the number of the power supply instance. CIM_LogicalDevice CreationClassName HP_WinPowerSupply DeviceID Unique identifier for this power supply instance SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName HP_ComputerSystem.
Table 4-3 Class: HP_PowerCollection Property name Property implementation GroupOperationalStatus[0] Represents the most severe power redundancy status and non-fault tolerant power supply operational status: 0 (Unknown)—If power collection status is unknown 2 (OK)—If power supplies are operating properly 3 (Degraded)—If no HP_WinPowerSupply.OperationalStatus[0] for all non-fault tolerant power supplies report 6 (Error) and HP_WinPowerRedundancySet.
Table 4-4 Class: HP_PowerRedundancySet Property name Property implementation ElementName Power Redundancy Set n, where n represents the number of the redundancy set instance CIM_SystemSpecificCollection InstanceID Unique identifier for this power redundancy instance CIM_RedundancySet MaxNumberSupported The maximum number of power supplies supported for this redundancy set MinNumberNeeded The minimum number of power supplies needed to function TypeOfSet 3 (Load Balanced) LoadBalanceAlgorithm 0 (
Table 4-5 Class: HP_MemberOfPowerRedundancy 4-3-5 Property name Property implementation Member References HP_PowerSupply HP_HostedPowerRedundancySet HP_HostedPowerRedundancySet is used to represent an association between HP_PowerRedundancySet and the computer system that contains this redundancy set. The Windows® implementation class is HP_WinHostedPowerRedundancySet.
4-3-8 HP_SystemPowerSupply HP_SystemPowerSupply is used to represent an association between HP_PowerSupply and the computer system that contains this power supply. The Windows® implementation class is HP_WinSystemPowerSupply. Table 4-9 Class: HP_SystemPowerSupply 4-3-9 Property name Property implementation GroupComponent References HP_ComputerSystem PartComponent References HP_PowerSupply HP_PowerSupplyModule HP_PowerSupplyModule is used to model the physical power supplies on ProLiant Servers.
Table 4-10 Class: HP_PowerSupplyModule Property name Property implementation CreationClassName ―HP_PowerSupplyModule‖ PartNumber The spare part number for the power supply (if available) Tag Unique identifier for this power supply module instance CIM_PhysicalPackage PackageType 6 (Power Supply) RemovalConditions 3 (Removable when off) 4 (Removable when on or off) HP_PowerSupplyModule 4-3-10 HP_PowerSupplySlot HP_PowerSupplySlot represents power supply bays on ProLiant Servers.
Table 4-11 Class: HP_PowerSupplySlot Property name Property implementation CIM_PhysicalElement CreationClassName ―HP_PowerSupplySlot‖ Tag Power Supply n, where n represents the physical bay number Description Power Supply n, where n represents the physical bay number ElementName Power Supply n, where n represents the physical bay number CIM_PhysicalConnector ConnectorLayout 7 (Slot) ConnectorPinout ―Custom Power Bay‖ ConnectorType 76 (Proprietary)—Custom Power Supply slot CIM_Slot Number Th
Table 4-13 Class: HP_RealizesPowerSupply 4-3-13 Property name Property implementation Antecedent References HP_PowerSupplyModule Dependent References HP_PowerSupply HP_SystemPhysicalPowerSupply Table 4-14 Class: HP_SystemPhysicalPowerSupply 4-3-14 Property name Property implementation GroupComponent References HP_ComputerSystemChassis PartComponent References HP_PowerSupplyModule HP_PowerMeter HP_PowerMeter is used to model the power consumption within power supplies on ProLiant Servers.
Table 4-15 Class: HP_PowerMeter Property name Property implementation HealthState 5 (OK)—If OperationalStatus[0] value is 2 (OK) Name Power Meter n, where n represents the number of the power meter instance CIM_LogicalDevice CreationClassName ―HP_WinPowermeter‖ DeviceID Unique identifier for this power meter instance SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName HP_ComputerSystem.
Table 4-16 Class: HP_AssociatedPowerMeter Property name Property implementation CIM_ AssociatedSensor HP_AssociatedPowerMeter 4-3-16 Antecedent ref: HP_PowerMeter Dependent ref: HP_PowerSupply CIM_SoftwareIdentity CIM_SoftwareIdentity describes power controller firmware. The Windows®-specific implementation class is HP_PowerControllerFirmware. The following properties are implemented.
Table 4-17 Class: CIM_SoftwareIdentity Property name Property implementation IdentifyingInfoType CIM:SoftwareFamily IsEntity false HP_PowerControllerFirmware 4-3-17 CIM_ElementSoftwareIdentity CIM_ElementSoftwareIdentity associates a managed element, in this case, an instance of HP_computer system to its corresponding power controller firmware. The Windows®-specific implementation class is HP_PowerControllerElementFirmwareIdentity. The following properties are implemented.
Table 4-19 Class: CIM_InstalledSoftwareIdentity Property name Property implementation HP_PowerControllerInstalledFirmwareIdentity 4-3-19 System ref:HP_ComputerSytem InstalledSoftware ref: HP_PowerControllerFirmware HP_Location HP_Location is used to model power supply locations on ProLiant servers. The Windows® implementation class is HP_WinPowerSupplyLocation.
Table 4-21 Class: HP_ElementLocation 4-3-21 Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location CIM_ConfigurationCapacity CIM_ConfigurationCapacity is used to model power supply configuration capacity on ProLiant Servers. The Windows® implementation class is HP_WinPowerSupplyConfigurationCapacity. There is one instance of this class on systems modeling power supply configuration capacity.
4-4 Supported indications The following indications are implemented for ProLiant server platforms where available. System power supply indications are described in the following tables.
Table 4-24 HP_SensorHardwareIdentification: Power Supply Removed Property name Property implementation OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, ..
4-4-2 Power Supply Inserted Table 4-25 HP_SensorHardwareIndication: Power Supply Inserted Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A power supply has been inserted. (PowerSupplyCaption), where PowerSupplyCaption is the HP_WinPowerSupply.Caption for the power supply that has been inserted.
Table 4-25 HP_SensorHardwareIndication: Power Supply Inserted Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, ..
Table 4-26 HP_SensorHardwareIndication: Power Supply Failed Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A power supply has failed. (PowerSupplyCaption), where PowerSupplyCaption is the HP_WinPowerSupply.Caption for the power supply that has failed.
Table 4-26 HP_SensorHardwareIndication: Power Supply Failed Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDo
Table 4-27 HP_SensorHardwareIndication: Power Supply Repaired Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A power supply has been repaired. (PowerSupplyCaption), where PowerSupplyCaption is the HP_WinPowerSupply. Caption for the power supply that has been repaired.
Table 4-27 HP_SensorHardwareIndication: Power Supply Repaired Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When I
Table 4-28 HP_SensorHardwareIndication: Power Supply Redundancy Reduced Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description A fault tolerant power supply is no longer providing power for a power redundancy set. (RedundancySetCaption), where RedundancySetCaption represents the HP_WinPowerRedundancySet.Caption for the redundancy set with reduced redundancy.
Table 4-28 HP_SensorHardwareIndication: Power Supply Redundancy Reduced Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other syst
Table 4-29 HP_SensorHardwareIndication: Power Supply Redundancy Lost Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description Power redundancy has been lost. (RedundancySetCaption), where RedundancySetCaption represents the HP_WinPowerRedundancySet.Caption for the redundancy set that lost redundancy. AlertingManagedElement WBEM path of the HP_WinPowerRedundancySet instance representing the redundancy set where redundancy was lost.
Table 4-29 HP_SensorHardwareIndication: Power Supply Redundancy Lost Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems
Table 4-30 HP_SensorHardwareIndication: Power Supply Redundancy Gained Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description A fault tolerant power supply has been added to a power redundancy set. (RedundancySetCaption), where RedundancySetCaption is HP_WinPowerRedundancySet.
Table 4-30 HP_SensorHardwareIndication: Power Supply Redundancy Gained Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other syste
Table 4-31 HP_SensorHardwareIndication: Power Supply Redundancy Restored Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description Power redundancy for the system has been restored. (RedundancySetCaption), where RedundancySetCaption is HP_WinPowerRedundancySet.
Table 4-31 HP_SensorHardwareIndication: Power Supply Redundancy Restored Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indicatio
Table 4-32 HP_SensorHardwareIndication: Power Supply Failed due to Input Power Loss Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A power supply has failed—Input power lost (PowerSupplyCaption), where PowerSupplyCaption is the HP_WinPowerSupply.Caption for the power supply that has failed.
Table 4-32 HP_SensorHardwareIndication: Power Supply Failed due to Input Power Loss Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating th
HP Confidential 5 System fan 5-1 Overview This provider implements the profiles listed to support fans installed in ProLiant servers. The following profiles are implemented, and the following files are installed by this provider. Table 5-1 Overview 5-2 Implemented Profiles HP Fan Profile 1.0 HP Fan Physical Asset Profile 1.0 HP Location Profile 1.0 Provider Installation Files HPWmiSensor.dll HPWmiSensorEvt.dll HPWmiSensorEvtMsg.dll HPWmiSensor.mof HPHlthEvtCons.
HP Confidential Table 5-2 Class: HP_Fan Property name Property implementation Caption Fan n, where n represents the number of the fan instance. Description Fan n provides cooling for fantype. statusdescription. n represents the number of the fan instance, fantype represents the corresponding string value of the FanType enumeration and statusdescription represents the value of StatusDescriptions[0] ElementName Fan n, where n represents the number of the fan instance.
HP Confidential 5-3-2 HP_CoolingCollection HP_CoolingCollection is used to model fan collections on ProLiant Servers. The Windows® implementation class is HP_WinCoolingCollection. There is one instance of this class on systems modeling fans. Table 5-3 Class: HP_CoolingCollection Property name Property implementation CIM_ManagedElement Caption Cooling Collection Description This is a collection of all devices including fans that provide cooling. GroupStatusDescription.
HP Confidential 5-3-3 HP_CoolingRedundancySet HP_CoolingRedundancySet is used to model fan redundancy sets on ProLiant servers. The Windows® implementation class is HP_WinCoolingRedundancySet. Table 5-4 Class: HP_CoolingRedundancySet Property name Property implementation CIM_ManagedElement Caption Cooling Redundancy Set n n represents the number of the redundancy set instance Description Cooling Redundancy Set n is collection of fault tolerant fans that provide redundant cooling.
HP Confidential 5-3-4 HP_MemberOfCoolingRedundancy HP_MemberOfCoolingRedundancy is used to represent an association between HP_Fan and HP_CoolingRedundancySet. The Windows® implementation class is HP_WinMemberOfCoolingRedundancy.
HP Confidential Table 5-8 Class: HP_HostedCoolingCollection 5-3-8 Property name Property implementation Antecedent References HP_ComputerSystem Dependent References HP_CoolingCollection HP_SystemFan HP_SystemFan is used to represent an association between HP_Fan and the computer system that contains this fan. The Windows® implementation class is HP_WinSystemFan.
HP Confidential Table 5-10 Class: HP_FanModule Property name Property implementation StatusDescriptions[0] ―Fan is operating properly‖—If OperationalStatus[0] is 2 (OK) ―Fan has failed‖—If OperationalStatus is 6 (Error) HealthState 5 (OK)—If fan is operating properly; 20 (Major Failure)—If fan has failed Name Fan n, where n represents the number of the fan instance CIM_PhysicalElement CreationClassName ―HP_FanModule‖ Tag Unique identifier for this fan module instance CIM_PhysicalPackage
HP Confidential Table 5-11 Class: HP_FanSlot Property name Property implementation CIM_PhysicalElement CreationClassName ―HP_FanSlot‖ Tag Fan n, where n represents the physical lot number Description Fan n, where n represents the physical lot number ElementName Fan n, where n represents the physical lot number CIM_PhysicalConnector ConnectorLayout 7 (Slot) ConnectorPinout ―Custom Fan Slot‖ ConnectorType 76 (Proprietary)—Custom Fan slot CIM_Slot Number The physical fan slot number Supports
HP Confidential Table 5-13 Class: HP_RealizesFan 5-3-13 Property name Property implementation Dependent References HP_Fan HP_SystemPhysicalFan HP_SystemPhysicalFan is used to represent an association between HP_FanModule and the computer system that contains this fan.
HP Confidential 5-3-15 HP_ElementLocation HP_ElementLocation is used to represent an association between CIM_Location and CIM_ManagedElement. The Windows® implementation class is HP_WinFanElementLocation. Table 5-16 Class: HP_ElementLocation 5-3-16 Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location CIM_ConfigurationCapacity CIM_ConfigurationCapacity is used to model fan configuration capacity on ProLiant Servers.
HP Confidential Table 5-18 Class: CIM_ElementCapacity 5-4 Property name Property implementation Capacity References CIM_PhysicalCapacity Element References CIM_PhysicalElement Supported indications The following indications are implemented for ProLiant server platforms where available. System fan indications are described in the following tables.
HP Confidential Table 5-19 HP_SensorHardwareIndication: Fan Removed Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-19 HP_SensorHardwareIndication: Fan Removed Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 5-20 HP_SensorHardwareIndication: Fan Inserted Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-20 HP_SensorHardwareIndication: Fan Inserted Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 5-21 HP_SensorHardwareIndication: Fan Failed Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-21 HP_SensorHardwareIndication: Fan Failed Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 5-22 Hp_SensorHardwareIndication: Fan Degraded Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-22 Hp_SensorHardwareIndication: Fan Degraded Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 5-23 Hp_SensorHardwareIndication: Fan Repaired Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-23 Hp_SensorHardwareIndication: Fan Repaired Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 5-24 HP_SensorHardwareIndication: Fan Redundancy Reduced Property name Property implementation ProbableCauseDescription Cooling Redundancy has been Reduced ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-24 HP_SensorHardwareIndication: Fan Redundancy Reduced Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 5-25 HP_SensorHardwareIndication: Fan Redundancy Lost Property name Property implementation ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Cooling Redundancy has been Lost. ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-25 HP_SensorHardwareIndication: Fan Redundancy Lost Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 5-26 HP_SensorHardwareIndication: Fan Redundancy Gained Property name Property implementation ProbableCauseDescription Cooling Redundancy has been Gained ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-26 HP_SensorHardwareIndication: Fan Redundancy Gained Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 5-27 HP_SensorHardwareIndication: Fan Redundancy Restored Property name Property implementation ProbableCauseDescription Cooling Redundancy has been Restored ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 5-27 HP_SensorHardwareIndication: Fan Redundancy Restored Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential 6 System temperature sensor 6-1 Overview This provider implements the HP Sensor Profile to model temperature sensors in ProLiant servers. The following profiles are implemented, and the following files are installed by this provider. Table 6-1 Overview 6-2 Implemented Profiles HP Sensor Profile 1.0 Provider Installation Files HPWmiSensor.DLL HPWmiSensorEvt.DLL HPWmiSensorEvtMsg.DLL HPWmiSensor.mof HPHlthEvtCons.mof HPErrorMetaInstance.mof HPWmiEvent.
HP Confidential Table 6-2 Class: HP_NumericSensor Property name Property implementation Description Temperature Sensor n detects for NumericSensorType. StatusDescription. n represents the number of the temperature sensor instance, NumericSensorType represents the value of NumericSensorType and StatusDescription represents the value of StatusDescriptions[0] ElementName Temperature Sensor n, where n represents the number of the temperature sensor instance.
HP Confidential Table 6-2 Class: HP_NumericSensor Property name Property implementation RequestedState 12 (Not Applicable) CIM_Sensor SensorType 2 (Temperature) CurrentState Normal—If OperationalStatus[0] is 2 (OK) Critical—If OperationalStatus[0] is 6 (Error) PossibleStates Array can contain any of the following values: Normal Degraded Critical CIM_NumericSensor CurrentReading Current reading of temperature sensor BaseUnits 2 (Degrees C) RateUnits 0 (None) UnitModifier 0 Suppor
HP Confidential 6-3-2 HP_SensorCollection HP_SensorCollection is used to model temperature sensor collections on ProLiant servers. The Windows® implementation class is HP_WinSensorCollection. There is one instance of this class on systems modeling sensors. Table 6-3 Class: HP_SensorCollection Property name Property implementation CIM_ManagedElement Caption Temperature Sensor Collection Description This is a collection of temperature sensors. GroupStatusDescription.
HP Confidential Table 6-4 Class: HP_MemberOfSensorCollection 6-3-4 Property name Property implementation Collection References HP_SensorCollection Member References HP_NumericSensor HP_HostedSensorCollection HP_HostedSensorCollection is used to represent an association between HP_SensorCollection and the computer system that contains the collection. The Windows® implementation class is HP_Win HostedSensorCollection.
HP Confidential Table 6-7 HP_SensorHardwareIndication: Temperature Sensor Recovery from Threshold Exceeded Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A temperature sensor has detected that the temperature has returned to a normal operating range. (SensorCaption)‖, where SensorCaption is the HP_WinNumericSensor.
HP Confidential Table 6-7 HP_SensorHardwareIndication: Temperature Sensor Recovery from Threshold Exceeded Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the compu
HP Confidential Table 6-8 HP_SensorHardwareIndication: Temperature Sensor Caution Threshold Exceeded Property name Property implementation CIM_AlertIndication Description A temperature sensor has detected that the temperature has exceeded the normal operating range. (SensorCaption) where SensorCaption is the HP_WinNumericSensor.Caption for the sensor that has failed.
HP Confidential Table 6-8 HP_SensorHardwareIndication: Temperature Sensor Caution Threshold Exceeded Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames Contains the temperature sensor threshold p
HP Confidential 7 System memory 7-1 Overview This provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory in ProLiant systems. See the HP Advanced Memory Protection Technologies (TC060104TB) and product documentation for your ProLiant server (available at http://www.hp.com). The following profiles are implemented, and the following files are installed by this provider. Table 7-1 Overview 7-2 Implemented Profiles HP Memory Profile 1.
HP Confidential There are three distinct hardware implementations and containment hierarchies of system memory on ProLiant server platforms: All memory resides on the system board only. All memory resides on memory boards only; no memory resides on the system board. Memory resides on both the system board and on memory boards. The following subsections depict these three distinct hardware scenarios with a pair of diagrams for each. The first diagram shows a hardware perspective for the scenario.
HP Confidential HP_ComputerSystem HP_SystemMemory HP_MemoryBoardSlot HP_MemoryBoardInSlot HP_SystemMemoryModuleSlot HP_MemoryCollection HP_MemberOfMemoryCollection HP_SystemMemoryBoardSlot HP_MemoryRedundancySet HP_MemberOfMemoryRedundancySet HP_HostedMemoryCollection HP_Memory HP_RealizesMemoryModule HP_ComputerSystemChassis HP_HostedMemoryRedundancySet HP_MemoryBoardSlotLocation HP_MemoryBoardSlotElementLocation HP_MemoryBoard HP_MemoryModuleSlotOnBoard HP_MemoryModuleSlot HP_MemoryModul
HP Confidential Hardware Platform Scenario 1: Memory Modulesreside on System Board Memory Module (DIMM) Memory Module Connector (Slot) plugs into resides on Chassis Example Instance Diagram HP_Memory Module HP_MemoryModuleInSlot HP_Memory ModuleSlot HP_SystemMemoryModuleSlot DIMM 0-1 DIMM 0-2 DIMM Slot 0-1 DIMM Slot 0-2 HP_Computer SystemChassis (empty) DIMM Slot 0-3 Chassis 1 (empty) DIMM Slot 0-4 7-3-2 Memory containment hierarchy—scenario 2 The following diagrams show the memory provide
HP Confidential Hardware Platform Scenario 2: Memory Modulesreside on Memory Boards Memory Module (DIMM) Memory Module Connector (Slot) plugs into resides on Memory Board Connector (Slot) plugs into Memory Board resides on Chassis Example Instance Diagram HP_Memory Module HP_MemoryModuleInSlot HP_Memory ModuleSlot HP_MemoryModuleSlotOnBoard DIMM 1-1 DIMM Slot 1-1 HP_Memory Board DIMM 1-2 HP_MemoryBoardInSlot HP_Memory BoardSlot DIMM Slot 1-2 (empty) DIMM Slot 1-3 HP_SystemMemoryBoardSlot
HP Confidential Hardware Platform Scenario 3: Memory Modulesreside on both System Board and Memory Boards Memory Module (DIMM) Memory Module Connector (Slot) plugs into resides on resides on Chassis Memory Board Connector (Slot) plugs into Memory Board Example Instance Diagram HP_Memory Module HP_MemoryModuleInSlot HP_Memory ModuleSlot HP_SystemMemoryModuleSlot DIMM Slot 0-1 DIMM 0-1 DIMM 0-2 DIMM Slot 0-2 (empty) DIMM Slot 0-3 (empty) DIMM Slot 0-4 HP_Memory Module HP_MemoryModuleInSlot H
HP Confidential Table 7-2 Class: HP_Memory Property name Property implementation Description Logical system memory ElementName System Memory CIM_ManagedSystemElement OperationalStatus Enumerator indicating the logical system memory operational status. The status represents the ‗worst-of‘ algorithm for all OperationalStatus[0] values reported by physical memory modules in HP_MemoryModule instances.
HP Confidential Table 7-2 Class: HP_Memory Property name Property implementation SystemName same value as property HP_ComputerSystem.
HP Confidential 7-4-3 HP_MemoryModule The class HP_MemoryModule represents a physical memory module on ProLiant servers. There is an instance of this class for each memory module present in the system. Empty memory module sockets are not instantiated. NOTE: In the property implementation descriptions below, memory modules located on the system board are denoted as being located on board/cartridge number 0 consistent with ProLiant tradition.
HP Confidential Table 7-4 Class: HP_MemoryModule Property name Property implementation Name Physical Memory Module y on Memory Board x, where: x is the board/cartridge number where the memory module is located y is the memory socket number where the memory module is located Physical Memory Module y on Processor Board x, where: x the processor board number where the memory module is located y is the memory socket number where the memory module is located CIM_PhysicalElement CreationClassName
HP Confidential Table 7-4 Class: HP_MemoryModule Property name Property implementation Manufacturer Name of the organization which produced the memory module This property is conditional. It is populated if the data is available. PartNumber Part number of the memory module. This property is conditional. It is populated if the data is available. SerialNumber Manufacturer allocated serial number of the memory module. This property is conditional. It is populated if the data is available.
HP Confidential Table 7-4 Class: HP_MemoryModule Property name Property implementation Spd An array that contains raw Serial Presence Detect information for the memory module. Each array element contains a byte of the Spd. This property is conditional; it is populated if the data is available. Type A numeric value idicating the presense of a HP Smart Memory module.
HP Confidential Table 7-5 Memory Module Status Condition OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Memory module is missing 0 (Unknown) Expected but missing Memory module Upgraded but not used 2(OK) Upgraded but Unused Memory module added but not used Memory module has correctable errors exceeding the condition for pre-failure warranty 7-4-4 Added but Unused
HP Confidential Table 7-6 Class: HP_MemoryBoard Property name Property implementation HealthState Enumerator indicating the memory board health state: 0 (Unknown), when OperationalStatus[0] = 0 (Unknown) 5 (OK), when OperationalStatus[0] = 2 (OK) 10 (Degraded/Warning), when OperationalStatus[0] = 3 (Degraded) Name Physical Memory Board x, where x is the board/cartridge number where the memory board is located.
HP Confidential Table 7-6 Class: HP_MemoryBoard Property name Property implementation HP_MemoryBoard Locked Indicates the locked state of the memory board: 1 (Not-Applicable), non-AMP systems only 2 (Unlocked) 3 (Locked) NumberOfSockets Number of memory module sockets on this board AvailableMemory Size of memory for this board seen by the operating system in MB TotalMemory Total size of memory for this board in MB Table 7-7 Memory Board Status Condition 7-4-5 OperationalStatus[0] Operati
HP Confidential Table 7-8 Class: HP_MemoryRedundancySet Property name Property implementation Caption Memory Redundancy Set Description Memory Redundancy Set for Advanced Memory Protection ElementName Memory Redundancy Set CIM_SystemSpecificCollection InstanceID HPQ:HP_MemoryRedundancySet:001 CIM_RedundancySet TypeOfSet The type of redundancy currently in operation for the Advanced Memory Protection system..
HP Confidential Table 7-8 Class: HP_MemoryRedundancySet Property name Property implementation CurrentConfigurations The current operating mode of the Advanced Memory Protection system.
HP Confidential Table 7-8 Class: HP_MemoryRedundancySet Property name Property implementation ConfigurationsAvailable An array containing Advanced Memory Protection configurations supported on this system (the CurrentConfiguration and TargetConfiguration properties will contain one of these values). Each indexed position in the array contains one supported configuration.
HP Confidential Table 7-9 Class: HP_MemoryCollection Property name Property implementation GroupOperationalStatus Enumerator indicating the group operational status of the memory collection. The status is determined as follows: If an instance of HP_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined from the property HP_MemoryRedundancySet.RedundancyStatus.
HP Confidential 7-4-7 HP_HostedMemoryCollection The class HP_HostedMemoryCollection represents an association between HP_MemoryCollection and the computer system that contains this collection.
HP Confidential Table 7-13 Class: HP_MemberOfMemoryRedundancySet 7-4-10 Property name Property implementation Member ref: HP_MemoryBoard HP_HostedMemoryRedundancySet The class HP_HostedMemoryRedundancySet represents an association between HP_MemoryRedundancySet and the computer system that contains this redundancy set.
HP Confidential Table 7-16 Class: HP_MemoryModuleSlot Property name Property implementation CIM_ManagedElement Caption Memory Module Socket y on Board x, where: x is the board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located Memory Module Socket y on Processor Board x, where: x is the processor board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located CIM_ManagedSystem
HP Confidential Table 7-16 Class: HP_MemoryModuleSlot Property name Property implementation Description Memory Module Socket y on Board x, where: x is the board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located Memory Module Socket y on Processor Board x, where: x is the processor board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located ElementName Memory Module Socke
HP Confidential 7-4-13 HP_MemoryBoardSlot The class HP_MemoryBoardSlot represents memory board slots on ProLiant Servers. There is an instance of this class for each memory board slot in the system, whether or not the slot is occupied. Table 7-17 Class: HP_MemoryBoardSlot Property name Property implementation CIM_ManagedElement Caption Memory Board Slot x, where x is the board/cartridge number where the memory board is located.
HP Confidential Table 7-17 Class: HP_MemoryBoardSlot Property name Property implementation CIM_Slot Number The board/cartridge number where the memory board is located. HP_MemoryBoardSlot 7-4-14 HP_MemoryModuleInSlot The class HP_MemoryModuleInSlot represents the association between an HP_MemoryModule and the HP_MemoryModuleSlot where it resides.
HP Confidential Table 7-20 Class: HP_MemoryModuleSlotOnBoard Property name Property implementation CIM_Component CIM_Container HP_MemoryModuleSlotOnBoard 7-4-17 GroupComponent ref: HP_MemoryBoard PartComponent ref: HP_MemoryModuleSlot HP_MemoryModuleSlotLocation The class HP_MemoryModuleSlotLocation extends the HP_Location class and represents memory module slot locations on ProLiant Servers.
HP Confidential Table 7-21 Class: HP_MemoryModuleSlotLocation Property name Property implementation ElementName Memory Module Socket Location y on Board x, where: x is the board/cartridge number where the memory module slot is located y is the memory socket number where the memory module slot is located Memory Module Socket Location y on Processor Board x, where: x is the processor board/cartridge number where the memory module slot is located y is the memory socket number where the memory m
HP Confidential 7-4-18 HP_MemoryBoardSlotLocation The class HP_MemoryBoardSlotLocation extends the HP_Location class and represents memory board slot locations on ProLiant Servers. There is an instance of this class for each memory board slot in the system, whether or not the slot is occupied.
HP Confidential 7-4-19 HP_MemoryModuleSlotElementLocation The class HP_MemoryModuleSlotElementLocation extends the class HP_ElementLocation and is used to associate a memory module slot (HP_MemoryModuleSlot) with its corresponding location (HP_MemoryModuleSlotLocation). There is an instance of this class for each memory module slot in the system, whether or not the slot is occupied.
HP Confidential Table 7-25 Class: HP_SystemMemoryModuleSlot Properites Property implementation CIM_Container HP_SystemMemoryModuleSlot 7-4-22 GroupComponent ref: HP_ComputerSystemChassis PartComponent ref: HP_MemoryModuleSlot HP_SystemMemoryBoardSlot The class HP_SystemMemoryBoardSlot represents an association between HP_MemoryBoardSlot and HP_ComputerSystemChassis. There is an instance of this class for each memory board slot in the chassis, whether or not the slot is occupied.
HP Confidential Table 7-27 HP_MemoryHardwareIndication: Memory Module Predictive Failure Property name Property implementation Description A memory module has failed or is predicted to fail. (MemoryModuleCaption), where MemoryModuleCaption is the HP_MemoryModuleCaption for the failing memory module.
HP Confidential Table 7-27 HP_MemoryHardwareIndication: Memory Module Predictive Failure Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames Tag or InstanceID Indicates that the HP_MemoryModule.Tag value for the failing memory module is populated in property VariableValues. VariableTypes 1 (string) VariableValues String containing the HP_MemoryModule.
HP Confidential Table 7-28 HP_MemoryHardwareIndication: Memory Board Error Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication IndicationTime Time of indication CIM_ProcessIndication CIM_AlertIndication Description A memory board has an error. (MemoryBoardCaption) where MemoryBoardCaption is the HP_MemoryBoard.Caption for the failing memory board.
HP Confidential Table 7-28 HP_MemoryHardwareIndication: Memory Board Error Property name Property implementation Network Address Contains a list of all the IP addresses of the computer system generating the indication SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the comput
HP Confidential Table 7-28 HP_MemoryHardwareIndication: Memory Board Error 7-5-3 Property name Property implementation AlertType 5 (Device Alert) Memory Redundancy Degraded Table 7-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication IndicationTime Time of indication CIM_ProcessIndication CIM_AlertIndication Description The Advanced Memory Protection (AMP) system is o
HP Confidential Table 7-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded Property name Property implementation OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion The operating system version of the computer system generating the indication in the following format: ..
HP Confidential Table 7-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product envir
HP Confidential Table 7-30 HP_MemoryHardwareIndication: Memory Recovered from Degraded Redundancy Property name Property implementation SystemName HP_ComputerSystem.
HP Confidential Table 7-30 HP_MemoryHardwareIndication: Memory Recovered from Degraded Redundancy Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential 8 PCI device 8-1 Overview This provider implements the profiles listed to support PCI devices installed in ProLiant servers. The following table details the profiles implemented and files installed by this provider. Table 8-1 Overview 8-2 Implemented Profiles DMTF PCI Device Profile DMTF Physical Asset Profile Provider Installation Files HPWmiPci.dll HPWmiPci.mof Use cases For use cases, see the DMTF PCI Device Profile.
HP Confidential Table 8-2 Class: HP_PCIDevice Property name Property implementation Name A hardware ID for this PCI device provided by the operating system CIM_LogicalDevice CreationClassName HP_PCIDevice DeviceID Unique identifier for this PCI device instance SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName HP_ComputerSystem.
HP Confidential Table 8-3 Class: HP_PCIBridge Property name Property implementation CIM_ManagedElement Caption A user-friendly description for this PCI device provided by the operating system Description A user-friendly description for this PCI device provided by the operating system ElementName A hardware ID for this PCI device provided by the operating system CIM_ManagedSystemElement Name A hardware ID for this PCI device provided by the operating system CIM_LogicalDevice CreationClassName HP_
HP Confidential Table 8-3 Class: HP_PCIBridge Property name Property implementation VendorID Vendor ID as described in the configuration registers for this PCI device CIM_PCIBridge BridgeType Enumeration describing the type of PCI bridge. See MOF. HP_PCIBridge 8-3-3 HP_PCICard HP_PCICard is used to represent physical PCI adapter card installed on ProLiant servers. There is an instance of this class for each PCI adapter card present in the system.
HP Confidential Table 8-4 Class: HP_PCICard Property name Property Implemenation BusLayout 16 (PCI) 17 (PCI-X) 18 (PCI-E) if lane count is unknown; otherwise use one of the following 19 (PCI-E x1) 20 (PCI-E x2) 21 (PCI-E x4) 22 (PCI-E x8) 23 (PCI-E x16) 24 (PCI-E x32) 25 (PCI-E x64) HostingBoard False HP_PCICard 8-3-4 HP_PCISlot HP_PCISlot represents PCI device slots on ProLiant servers. There is an instance of this class for each PCI slot in the system, whether or not the slot is occupied.
HP Confidential Table 8-5 Class: HP_PCISlot Property name Property implementation ConnectorLayout 16 (PCI) 17 (PCI-X) 18 (PCI-E) if lane count is unknown; otherwise use one of the following 19 (PCI-E x1) 20 (PCI-E x2) 21 (PCI-E x4) 22 (PCI-E x8) 23 (PCI-E x16) 24 (PCI-E x32) 25 (PCI-E x64) ConnectorPinout PCI—If this is a 33 MHz PCI slot PCI-66—If this is a 66 MHz PCI slot PCI-X—If this is a PCI-X slot PCI Express Gen2—If this is a PCI Express Gen2 slot PCI Express Gen3—If this is a PCI Ex
HP Confidential 8-3-5 HP_PCICardInSlot HP_PCICardInSlot is used to represent an association between HP_PCICard and HP_PCISlot that contains this PCI card. Table 8-6 Class: HP_PCICardInSlot 8-3-6 Property name Property implementation Antecedent References HP_PCISlot Dependent References HP_PCICard HP_RealizesPCIDevice HP_RealizesPCIDevice is used to represent an association between HP_PCIDevice and HP_PCICard that realizes this PCI device.
HP Confidential Table 8-9 Class: HP_SystemPCIDevice 8-3-9 Property name Property implementation PartComponent References HP_PCIDevice HP_Location HP_Location is used to model PCI slot locations on ProLiant Servers. The Windows®-specfic implementation class is HP_PCISlotLocation. Table 8-10 Class: HP_Location Property name Property implementation CIM_ManagedElement Caption PCI slot n, where n represents the PCI slot position printed on the system labeling. Description The location of PCI slot n.
HP Confidential 8-4 Supported indications There are no indications specific to the PCI device implementation.
9 Management Processor Lite 9-1 Overview The profiles are implemented, and the following files are installed by this provider. Table 9-1 Overview 9-2 Implemented Profiles HP Management Processor (MP) Lite Profile 1.0 Provider Installation Files HPWmiMgmtProc.dll HPWmiMgmtProcLite.mof HPWmiMgmtProcEvt.dll HPWmiMgmtProcEvtMsg.dll HPWmiEvent.mof HPErrorMetaInstance.mof Use cases For use cases, see the HP Management Processor (MP) Lite Profile.
Table 9-2 Class: HP_ManagementProcessor Property name Property implementation Description Description of the Management Processor in the format: HP Management Processor - where indicates the MP Is Active or Inactive/Disabled and is the name of the MP product (same as the product name in property ElementName) For example, Active HP Management Processor – Integrated Lights Out (iLO) ElementName Product name of the management processor.
Table 9-2 Class: HP_ManagementProcessor Property name Property implementation StatusDescriptions Descriptive text per OperationalStatus.
Table 9-2 Class: HP_ManagementProcessor Property name Property implementation ControllerType Enumerator indicating the model or type of management processor (see the HPWmiMgmtProcLite.mof file).
Table 9-2 Class: HP_ManagementProcessor Property name Property implementation IPv6AddressSources Address Source of the corresponding IPv6 Address in ManagementIPAddresses property IPv6AddressPrefixLengths Prefix Length of the corresponding IPv6 Address in ManagementIPAddresses property IPv6CurrentStates Current State of the corresponding IPv6 Address in ManagementIPAddresses property. URL The Uniform Resource Locator of the management processor controller‘s web-based user interface.
9-3-2 CIM_SoftwareIdentity CIM_SoftwareIdentity describes management processor firmware. The Windows®-specfic implementation class is HP_MPFirmware. The following properties are implemented.
Table 9-4 Class: CIM_SoftwareIdentity Property name Property implementation ClassificationDescriptions HP Management Processor Firmware IdentityInfoValue An array in which first element contains the path of the target type/firmware family and the second element is of format HPQ:xxx, where xxx represents the target type/firmware family Examples: HPQ:RI6 for RILOE-II HPQ:RI5 for iLO HPQ:RI7 for ILO2 HPQ:RI9 for iLO3 HPQ:RI10 for iLO4 IdentifyingInfoType CIM:SoftwareFamily ReleaseDate The
Table 9-5 Class: HP_MPCollection Property name Property implementation GroupOperationalStatus Describes the group operational status of the management processor collection (refer to HP Management Processor (MP) Lite Profile). The group operational status represents the ‗worst-of‘ algorithm for all individual MP statuses in HP_ManagementProcessor.OperationalStatus[0].
Table 9-7 Class: HP_MPComponentCS Property name Property implementation CIM_Component CIM_SystemComponent CIM_ComponentCS HP_MPComponentCS 9-3-6 GroupComponent ref: HP_ComputerSystem PartComponent ref: HP_ManagementProcessor HP_MPMemberOfCollection HP_MPMemberOfCollection extends the class CIM_MemberOfCollection and associates a management processor to the collection to which it belongs. The following properties are implemented.
Table 9-9 Class: CIM_ElementSoftwareIdentity Property name Property implementation ElementSoftwareStatus ElementSoftwareStatus[0]: 6 (Installed) ElementSoftwareStatus[1]: 2 (Current) HP_MPElementFirmwareIdentity 9-3-8 Antecedent ref: HP_MPFirmware Dependent ref: HP_ManagementProcessor CIM_InstalledSoftwareIdentity CIM_InstalledSoftwareIdentity associates a management processor to its corresponding installed firmware. The Windows®-specific implementation class is HP_MPInstalledFirmwareIdentity.
Table 9-11 HP_ManagementProcessorIndication: Management Processor in Reset State Property name Property implementation ProviderName HP MgmtProc RecommendedActions None. SystemName HP_ComputerSystem.SystemName SystemCreationClassName HP_ComputerSystem.
Table 9-11 HP_ManagementProcessorIndication: Management Processor in Reset State Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional pro
Table 9-11 HP_ManagementProcessorIndication: Management Processor has been reset Property name Property implementation ProbableCauseDescription NONE ProviderVersion Provider version generating the indication in the format, ...
Table 9-11 HP_ManagementProcessorIndication: Management Processor has been reset Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
Table 9-11 HP_ManagementProcessorIndication: Management Processor Reset Failed Property name Property implementation OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, ..
10 IML record log 10-1 Overview This provider supports the Integrated Management Log (IML) on ProLiant servers. The following profiles are implemented, and the following files are installed by this provider. Table 10-1 Overview 10-2 Implemented Profiles HP Record Log Profile (P00109) Provider Installation Files HPWmiSys.dll HPWmiSys.mof Use cases For use cases, see the HP Record Log profile (P00109). 10-3 Class implementations The following classes describe the IML Record Log implementation.
Table 10-2 Class: HP_CommonRecordLog Properties Property name Property implementation OperationalStatus OperationalStatus[0] indicates the highest severity of IML log entries and will contain one of the following: 2 (OK), only informational or repaired events exist in the IML log 3 (Degraded), at least one degraded event exists in the IML log 6 (Error), at least one critical event exists in the IML log StatusDescriptions StatusDescriptions[0] will contain one of the following corresponding to O
Table 10-3 Implemented Methods for HP_CommonRecordLog Class 10-3-2 Method Name Method Implementation ClearLog Refer to HP Record Log profile (P00109) RepairAll Refer to HP Record Log profile (P00109) HP_CommonLogEntry HP_CommonLogEntry extends the class CIM_LogEntry to model log records within the IML log. The IML implementation class is HPQ_CommonLogEntry. The following properties are implemented.
Table 10-4 Class: HP_CommonLogEntry Property name Property implementation Severity 0 (Unknown) For Windows 2003 32-bit: 69 OSType 2 (Information) 3 (Repaired) 4 (Degraded/Warning) 7 (Critical) For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 SystemSerialNumber System serial number string from SMBIOS SystemProductID System product ID string from SMBIOS SystemModel System model number string
Table 10-6 Class: HP_LogManagesRecord 10-3-4 Property name Property implementation Log ref: HP_CommonRecordLog Record ref: HP_CommonLogEntry HP_UseOfLog HP_ UseOfLog extends the class CIM_UseOfLog and associates the instance of HP_ComputerSystem with the instance of HP_CommonRecordLog. The IML implementation class is HPQ_UseOfLog. The following properties are implemented.
HP Confidential 11 Platform Watchdog 11-1 Overview This provider supports the Platform Watchdog on ProLiant servers. The following table details the profiles implemented and files installed by this provider. Table 11-1 Overview 11-2 Implemented Profiles DMTF Platform Watchdog Profile (DSP1040) Provider Installation Files HPWmiSensor.dll HPWmiSensor.mof Use cases For use cases, see the DMTF Platform Watchdog Profile.
HP Confidential Table 11-2 Class: HP_WinPlatformWatchdogService Property name Property implementation OperationalStatus OperationalStatus[0] indicates the operational state of the watchdog timer: 2 (OK), Watchdog has not expired 6 (Error), Watchdog has expired StatusDescriptions StatusDescriptions[0] contains one of the following corresponding to OperationalStatus[0]: Watchdog status OK Watchdog status error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledStat
HP Confidential implementation HP_WinHostedWatchdogService instantiated on a ProLiant server. The following table lists the properties implemented.
HP Confidential Table 11-5 Class: CIM_ServiceAvailableToElement 11-4 Property name Property implementation UserOfService ref: HP_OperatingSystem Supported indications There are no indications specific to the profile registration implementation.
HP Confidential 12 BladeSystem Lite 12-1 Overview The following profiles are implemented, and the following files are installed by this provider. Table 12-1 Overview 12-2 Implemented Profiles HP BladeSystem Lite Profile 1.0 Provider Installation Files HPWmiBlade.DLL HPWmiBlade.mof Use cases For use cases, see the HP BladeSystem Lite Profile. 12-3 Class implementations The following classes are implemented for ProLiant BladeSystems and multinode servers.
HP Confidential Table 12-2 Class: HP_BladeEnclosureCS Property name Property implementation Description For Blade SystemIf enclosure name exists: HP BladeSystem c-Class enclosure otherwise: HP BladeSystem c-Class enclosure For Multi-Node Chassis SystemHP Multi-node system chassis ElementName For Blade SystemIf enclosure name exists: HP BladeSystem c-Class enclosure otherwise: HP BladeSystem c-Class enclosure For Multi-Node Chassis System- HP Multi-node system chassi
HP Confidential Table 12-2 Class: HP_BladeEnclosureCS Property name Property implementation RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_System CreationClassName HP_BladeEnclosureCS CIM_ComputerSystem Dedicated 2 (Other) OtherDedicatedDescriptions Modular, for Blade Systems Multi-Node, for multinode servers IdentifyingDescriptions IdentifyingDescriptions[0]: HPQ:ProductID IdentifyingDescriptions[1]: CIM:Model:SerialNumber OtherIdentifyingInfo OtherIdentifyingInfo[0
HP Confidential 12-3-2 HP_BladeEnclosureCollection HP_BladeEnclosureCollection extends the class HP_GroupSystemSpecificCollection to aggregate the enclosure‘s group operational status. The following properties are implemented.Multi-Node servers do not populate this class.
HP Confidential 12-3-3 HP_BladeSystemComponent HP_BladeSystemComponent extends the class CIM_SystemComponent and associates the enclosure/multi-node chassis computer system instance to the blade/node computer system instance. The following properties are implemented.
HP Confidential Table 12-6 Class: HP_BladeEnclosureGroupHostedCollection Property name Property implementation HP_GroupHostedCollection HP_BladeEnclosureGroupHostedCollection 12-3-6 Antecedent ref: HP_ComputerSystem Dependent ref: HP_BladeEnclosureCollection CIM_SoftwareIdentity CIM_SoftwareIdentity describes blade enclosure firmware. The Windows®-specific implementation class is HP_BladeEnclosureFW. The following table lists the properties implemented. Multi-Node servers do not populate this class.
HP Confidential Table 12-7 Class: CIM_SoftwareIdentity Property name Property implementation Classifications 10 (Firmware) ClassificationDescriptions HP Server Blade Enclosure Firmware IdentityInfoValue ―HPQ:OA‖ IdentityInfoType CIM:SoftwareFamily HP_BladeEnclosureFW 12-3-7 CIM_ElementSoftwareIdentity CIM_ElementSoftwareIdentity associates a blade enclosure to its corresponding firmware. The Windows®-specific implementation class is HP_BladeEnclosureElementFWIdentity.
HP Confidential Table 12-9 Class: CIM_InstalledSoftwareIdentity 12-3-9 Property name Property implementation InstalledSoftware ref: HP_BladeEnclosureFW HP_Location HP_Location is used to model the server blade location within an enclosure or the server node location in the Multi-Node Chassis. The Windows®-specific implementation class is HP_BladeCSLocation.
HP Confidential Table 12-10 Class: HP_Location Property name Property implementation PhysicalPosition “n”, where n representsthe blade bay slot position printed on the enclosure labeling,for Blade Systems the Node‘s Bay number in the Chassis,for Multi-Node Systems HP_Location ElementLocationTag The computer system name ElementLocationTagDesc 24 (Blade) 25 (Server Node) LocationInformation LocationInformation[0]: The blade bay number within the enclosure, for Blade Systems The Server Node Bay numbe
HP Confidential 12-3-10 HP_ElementLocation HP_ElementLocation is used to represent an association between CIM_Location and CIM_ManagedElement. The Windows®-specific implementation class is HP_BladeCSElementLocation. Table 12-11 Class: HP_ElementLocation 12-4 Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location Supported indications There are no indications specific to the BladeSystem implementation.
HP Confidential 13 Ethernet teaming 13-1 Overview The following profiles are implemented, and the following files are installed by this provider. Table 13-1 Overview Implemented Profiles HP Ethernet Teaming 1.
HP Confidential Table 13-1 Overview Provider Installation Files HPWinEthAdapterCollection.dll HPWinEthBootcodeVersion.dll HPWinEthBootcodeVersionToPort.dll HPWinEthDevice.dll HPWinEthernetPort.dll HPWinEthernetPortStatistics.dll HPWinEthernetStrings.dll HPWinEthGroupHostedCollection.dll HPWinEthIndicationProvider.dll HPWinEthIPHostedAccessPoint.dll HPWinEthIPProtocolEndpoint.dll HPWinEthLANEndpoint.dll HPWinEthLANEndpointToStats.
HP Confidential Table 13-1 Overview Provider Installation Files continued 13-2 HPWinEthernetPort.mof HPWinEthernetPortStatistics.mof HPWinEthernetProvider.mof HPWinEthErrorMetadata.mof HPWinEthEventSettings.mof HPWinEthGroupHostedCollection.mof HPWinEthIPHostedAccessPoint.mof HPWinEthIPProtocolEndpoint.mof HPWinEthLANEndpoint.mof HPWinEthLANEndpointToStats.mof HPWinEthLANHostedAccessPoint.mof HPWinEthMemberOfCollection.mof HPWinEthPortToLANEndpoint.
HP Confidential Table 13-2 Class: HP_EthernetPort Property name Property implementation ElementName Same as Caption CIM_ManagedSystemElement Name Physical Device Object (PDO) name (for example, \Device\NTPNP_PCI0017) HealthState 5 (OK) if port has link, 20 (Major Failure) otherwise OperationalStatus[0] 2 (OK) if port has link, 6 (Error) otherwise CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled).
HP Confidential Table 13-2 Class: HP_EthernetPort Property name Property implementation HP_EthernetPort VirtualPortNumber 13-3-2 Virtual Port Number for FlexNics HP_EthernetDevice HP_EthernetDevice associates an Ethernet Port to the containing Computer System. The Windows® implementation class is HP_WinEthDevice.
HP Confidential Table 13-4 Class: HP_EthernetTeam Property name Property implementation MaxNumberSupported Number of ports configured in team. MinNumberNeeded 1 OtherLoadBalanceAlgorithm When LoadBalanceAlgorithm is 1 (Other), OtherLoadBalanceAlgorithm is set to configured Load Balance Algorithm (for example Automatic) RedundancyStatus 2 (Fully Redundant) 3 (Degraded Redundancy) 4 (Redundancy Lost) 5 (Overall Failure). 2 (N+1) 3 (Load Balanced).
HP Confidential Table 13-5 Class: HP_EthernetTeamMember Property name Property implementation Key:Collection ref: HP_EthernetTeam Key:Member ref:HP_EthernetPort HP_EthernetTeamMember MemberOperationalStatus 2 (OK) 3 (Degraded) 6 (Error) MemberStatusDescriptions See the HP Ethernet Teaming Profile.
HP Confidential Table 13-7 Class: HP_EthernetLANEndpoint Property name Property implementation Caption For Ethernet Teams, same as associated HP_WinEthRedundancySet.Caption For Ethernet Ports, same as associated HP_WinEthernetPort.
HP Confidential 13-3-7 HP_EthernetPortToLANEndpoint HP_EthernetPortToLANEndpoint associates Ethernet Ports to Ethernet LAN Endpoints. The Windows® implementation class is HP_WinEthPortToLANEndpoint.
HP Confidential 13-3-10 HP_IPBindsToEthernetLANEndpoint HP_IPBindsToEthernetLANEndpoint associate IP Protocol Endpoints to LAN Endpoints. The Windows® implementation class is HP_WinIPBindsToEthLANEndpoint.
HP Confidential Table 13-12 Class: HP_EthernetStatistics Property name Property implementation CIM_EthernetPortStatistics AlignmentErrors See the CIM_EthernetPortStatistics mof DeferredTransmissions See the CIM_EthernetPortStatistics mof ExcessiveCollisions See the CIM_EthernetPortStatistics mof FCSErrors See the CIM_EthernetPortStatistics mof InternalMACReceiveErrors See the CIM_EthernetPortStatistics mof InternalMACTransmitErrors See the CIM_EthernetPortStatistics mof LateCollisions See th
HP Confidential 13-3-14 HP_EthernetCollection The following table lists the property implementation for HP_EthernetCollection. The Windows® implementation class is HP_WinEthAdapterCollection.
HP Confidential Table 13-17 Class: HP_EthernetGroupHostedCollection Property name Property implementation CIM_Dependency Key:Antecedent ref:HP_ComputerSystem Key:Dependent ref:HP_EthernetCollection CIM_HostedDependency CIM_HostedCollection HP_EthernetGroupHostedCollection 13-3-17 CIM_IPProtocolEndpoint The following table lists the property implementation for CIM_IPProtocolEndpoint. The Windows® implementation class is HP_WinEthIPProtocolEndpoint.
HP Confidential Table 13-18 Class: CIM_IPProtocolEndpoint Property name Property implementation CIM_IPProtocolEndpoint IPv4Address IPV4 Address (dot notation format) IPv6 Address IPv6 Address (CIDR format) SubnetMask Subnet Mask (not populated for IPv6) 13-3-18 HP_EthIPHostedAccessPoint CIM_HostedAccessPoint associates IP Protocol Endpoints to the Computer System. The Windows® implementation class is HP_WinEthIPHostedAccessPoint.
HP Confidential Table 13-20 Class: CIM_SoftwareIdentity Property name Property implementation CIM_LogicalElement CIM_SoftwareIdentity BuildNumber The build number of the software ClassificationDescriptions[0] Firmware Classifications[0] 10 (Firmware) Key:InstanceId System GUID for the associated Ethernet Port IdentityInfoType CIM:SoftwareFamily IdentityInfoValue[0] HPQ:PCI Vendor Id MajorVersion Major number component of the Boot Code or PXE Manufacturer Hewlett Packard Company MinorVersi
HP Confidential Table 13-22 Class: HP_Location Property name Property implementation CIM_ManagedElement Caption Same as associated ethernet port Description Same as associated ethernet port ElementName Same as caption CIM_Location Key:Name Local Area Connection # Key:PhysicalPostion System GUID for the associated Ethernet Port HP_Location ElementLocationTag PCI Bus:Device:Function ElementLocationTagDesc 15 (PCI Bus:Device:Function) LocationInfoDesc[] 0 (Slot), and/or 1 (Mezzanine Slot), an
HP Confidential Table 13-24 Class: HP_EthEventSettings Property name Property implementation CIM_SettingData Caption HP Ethernet Event Provider configurable settings for Windows Description HP Ethernet Event Provider configurable settings for Windows ElementName HP Ethernet Event Provider configurable settings for Windows Key:InstanceId 0 HP_EthEventSettings HP_WinEthEventSettings ActiveAdapterCountChanged If enabled, an event is generated when a change is detected in number of active adapter co
HP Confidential 13-4 Supported indications The following indications are implemented for ProLiant server platforms where available. System Ethernet Port, Ethernet Team, and Ethernet LAN Endpoint indications are described in the following tables. For nonteamed Ethernet Ports, if the associated HP_EthernetMemberOfCollection.Included is False, the following indications are disabled. For teamed Ethernet Ports, this association does not exist.
HP Confidential Table 13-25 HP_AlertIndication: Ethernet Team Redundancy Lost Property name Property implementation EventSubCategory 12 - Ethernet Team NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indica
HP Confidential Table 13-25 HP_AlertIndication: Ethernet Team Redundancy Lost 13-4-2 Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 13-26 HP_AlertIndication: Ethernet Team Redundancy Increased Property name Property implementation NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, .
HP Confidential Table 13-26 HP_AlertIndication: Ethernet Team Redundancy Increased 13-4-3 Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 13-27 HP_AlertIndication: Ethernet Team Redundancy Decreased Property name Property implementation EventSubCategory 12 (Ethernet Team)) 13 (Ethernet LAN Endpoint) NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the
HP Confidential Table 13-27 HP_AlertIndication: Ethernet Team Redundancy Decreased 13-4-4 Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate prod
HP Confidential Table 13-28 HP_AlertIndication: Ethernet Team Full Redundancy Restored Property name Property implementation EventCategory 9 (Network Device) EventSubCategory 12 (Ethernet Team) NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version
HP Confidential Table 13-28 HP_AlertIndication: Ethernet Team Full Redundancy Restored 13-4-5 Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate
HP Confidential Table 13-29 HP_AlterIndication: Network Interface Connectivity Lost Property name Property implementation SystemName Name of the computer system generating the indication HP_AlertIndication Summary Network interface lost connectivity.
HP Confidential Table 13-29 HP_AlterIndication: Network Interface Connectivity Lost 13-4-6 Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 13-30 HP_AlertIndication: Network Interface Connectivity Restored Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary Network connectivity restored.
HP Confidential Table 13-30 HP_AlertIndication: Network Interface Connectivity Restored Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. 13-4-7 BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 13-31 Optional HP_AlertIndication: Ethernet Team Member Status Change Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) Event Id 10 ProviderName HP Ethernet RecommendedActions[] View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information.
HP Confidential Table 13-31 Optional HP_AlertIndication: Ethernet Team Member Status Change Property name Property implementation VariableTypes[0] 1 (string) VariableValues[0] WBEM path of the Ethernet Port, HP_WinEthernetPort, whose status has changed. VariableName[1] PreviousStatus VariableTypes[1] 1 (string) VariableValue[1] Previous HP_WinEthernetTeamMember.
HP Confidential Table 13-31 Optional HP_AlertIndication: Ethernet Team Member Status Change 13-4-8 Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 13-32 Optional HP_AlertIndication: Ethernet Team Member Role Change Property name Property implementation EventSubCategory 12 (Ethernet Team) NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generatin
HP Confidential Table 13-32 Optional HP_AlertIndication: Ethernet Team Member Role Change 13-4-9 Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 13-33 Optional HP_AlertIndication: Ethernet Team Member Dropped Property name Property implementation RecommendedActions[] View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information.
HP Confidential Table 13-33 Optional HP_AlertIndication: Ethernet Team Member Dropped Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 13-34 Optional HP_AlertIndication: Ethernet Team Member Added Property name Property implementation AlertType 2 (Communications Alert) Event Id 7 ProviderName HP Ethernet RecommendedActions[] None SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary An Ethernet Team Member has been added to the team.
HP Confidential Table 13-34 Optional HP_AlertIndication: Ethernet Team Member Added Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 13-35 Optional HP_AlertIndication: Network Interface No Longer Available Property name Property implementation RecommendedActions[] View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information.
HP Confidential Table 13-35 Optional HP_AlertIndication: Network Interface No Longer Available Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 13-36 HP_AlertIndication: New Network Interface Available Property name Property implementation RecommendedActions[] None SystemCreationClassName CreationClassName of the computer system generating the indication SystemName Name of the computer system generating the indication HP_AlertIndication Summary A new network interface is available EventCategory 9 (Network Device) EventSubCategory 11 (Ethernet Port) 12 (Ethernet Team) 13 (Ethernet LAN Endpoint) NetworkAddre
HP Confidential Table 13-36 HP_AlertIndication: New Network Interface Available Property name Property implementation EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 13-37 HP_AlertIndication: Ethernet Team Active Member Count Change Property name Property implementation RecommendedActions[] View the Ethernet and Ethernet Team Member status in the HP Network Configuration Utility (NCU). View the System Event Log for additional information.
HP Confidential Table 13-37 HP_AlertIndication: Ethernet Team Active Member Count Change Property name Property implementation VariableValues[1] Current Count of active adapters ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 13-38 Optional HP_AlertIndication: Ethernet Provider Fatal Error Property name Property implementation AlertType 2 (Communications Alert) Event Id 1 ProviderName HP Ethernet RecommendedActions[] Contact HP Support.
HP Confidential Table 13-38 Optional HP_AlertIndication: Ethernet Provider Fatal Error Property name Property implementation VariableTypes[1] 5 (uint32) VariableValues[1] Current state. VariableNames[2] State 2, VariableTypes[2] 5 (uint32) VariableValues[2] Changed state. ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.
HP Confidential Table 13-39 Optional HP_AlertIndication: Ethernet Provider Cannot Access Data Source Property name Property implementation AlertingManagedElement WBEM path of the Ethernet Port (HP_WinEthernetPort), Ethernet Team (HP_WinEthRedundancySet) or Ethernet LAN Endpoint (HP_WinEthLANEndpoint) reporting warning AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) Event Id 14 ProviderName HP Ethernet RecommendedActions[] Isolated instances of this event are not a ca
HP Confidential Table 13-39 Optional HP_AlertIndication: Ethernet Provider Cannot Access Data Source Property name Property implementation SystemProductId Product ID of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
HP Confidential 14 Operating system status 14-1 Overview This provider supports the Operating System status on ProLiant servers. The following table details the profiles implemented and files installed by this provider. Table 14-1 Overview 14-2 Property name Property implementation Implemented Profiles DMTF OS Status Profile (DSP1040) Provider Installation Files HPWmiSys.dll HPWmiSys.mof Use cases For use cases, see the DMTF OS Status Profile.
HP Confidential Table 14-2 Class: HP_OperatingSystem Property name Property implementation ElementName Sample value: Windows Server 2008 Standard CIM_ManagedSystemElement HealthState 5 (OK), when OperationalStatus[0]=2 (OK) InstallDate Date of the OS install Name Sample value: Windows Server® 2008 Standard OperationalStatus[0] OperationalStatus[0] indicates the operational state of the OS: 2 (OK), Operating System OK StatusDescriptions[0] StatusDescriptions[0] will contain one of the following
HP Confidential Table 14-2 Class: HP_OperatingSystem Property name Property implementation OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 SizeStoredInPagingFiles Total number of Kbytes of paging file memory TotalVirtualMemorySize Total number of Kbytes of virtual memory TotalVisibleMemorySize Total number of Kbytes of physical memory Version A string describing the Operating System's version num
HP Confidential Table 14-4 Class: CIM_InstalledOS Property name Property implementation CIM_SystemComponent CIM_InstalledOS 14-4 GroupComponent ref: HP_ComputerSystem PartComponent ref: HP_OperatingSystem PrimaryOS TRUE if this is the primary Operating System FALSE if this is not the primary Operating System Supported indications There are no indications specific to the OS Status profile implementation.
HP Confidential 15 Smart Array 15-1 Overview The HP Smart Array data sheet describes both host-based Smart Array HBA devices and externally attached MSA devices. This implementation excludes fibre-attached devices (for example, MSA1000 and MSA1500). The following profiles are implemented, and the following files are installed by this provider. Table 15-1 Overview 15-2 Implemented Profiles HP Smart Array Profile (P00121) Provider Installation Files HPWMISA.dll HPWMISAEventMsg.
HP Confidential Table 15-2 Class: HPSA_ArraySystem (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller/Storage System name and location Examples: Smart Array in Slot 3, for internal MSA500 in SystemCab03, for external CIM_ManagedSystemElement Name Controller Serial Number EMBEDDED—Reported if there is no Serial Number for device is local (embedded on motherboard).
HP Confidential Table 15-2 Class: HPSA_ArraySystem (CIM_ComputerSystem) Property name Property implementation CIM_ComputerSystem Dedicated[0]: 3 (External Storage) or 30 (Host- Dedicated based RAID controller) Dedicated[1]: 15 (Block Server) Identify() See HP Smart Array Profile 15-3-2 HPSA_ArrayController HPSA_ArrayController represents the controller. There is one per HBA. External subsystems can have multiple controllers.
HP Confidential Table 15-3 Class: HPSA_ArrayController (CIM_ComputerSystem) Property name Property implementation CIM_ComputerSystem Dedicated Dedicated[0] 0 (Not Dedicated) HPSA_Arraycontroller AcceleratorBackupPowerSource See HP Smart Array Profile ADGSupported See HP Smart Array Profile BatteryStatus See HP Smart Array Profile CacheBoardPresent See HP Smart Array Profile All the following values related to Cache are appear only if the Variable is set to TRUE.
HP Confidential Table 15-4 Class: HPSA_StorageVolume (CIM_StorageVolume) Property name Property implementation CIM_ManagedElement ElementName Logical drive number with raid description (for example, Logical Volume 1 (RAID 1+0)) CIM_ManagedSystemElement Name VPD Pg83 identifier for the volume. OperationalStatus[0, 1] Volume status. DMTF defined value is populated in index[0] and extended status is poplulated in index[1] per HP Smart Array Profile.
HP Confidential Table 15-4 Class: HPSA_StorageVolume (CIM_StorageVolume) Property name Property implementation NameFormat 2 (VPD83NAA6) PackageRedundancy 0 (RAID 0) 1 (RAID 1+0, RAID 5, RAID 1 (ADM), RAID 1+0 (ADM)) 2 (RAID 6, RAID 50) CIM_Storagevolume HPSA_Storagevolume Accelerator See HP Smart Array Profile Deleteable See HP Smart Array Profile FaultTolerance See HP Smart Array Profile OSName Corresponding OS name for this volume.
HP Confidential Table 15-5 Class: HPSA_DiskDrive (CIM_DiskDrive) Property name Property implementation CIM_ManagedElement Description Interface Type of the Physical Drive e.
HP Confidential Table 15-5 Class: HPSA_DiskDrive (CIM_DiskDrive) Property name Property implementation NegotiatedSpeed See HP Smart Array Profile Identify() See HP Smart Array Profile SSDTotalPowerOnHours This is the total number of hours that the Solid State Disk has been powered on. SSDPercentageEnduranceUsed This is the Physical Drive Solid State Percent Endurance Used. SSDLifeRemaining This is the Solid State drive life remaining days until wear out.
HP Confidential Table 15-6 Class: HPSA_StorageExtent (CIM_StorageExtent) Property name Property implementation RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSA_StorageExtent DeviceID Opaque ID SystemCreationClassName HPSA_ArraySystem SystemName HPSA_ArraySystem.
HP Confidential Table 15-7 Class: HPSA_DiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation Classifications[0] 10 (Firmware) InstanceID Opaque key IsEntity False(always set to False) Manufacturer Disk drive vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ: VersionString Drive firmware as reported from SCSI identify command HPSA_DiskDriveFirmware 15-3-7 HPSA_PhysicalPackage HPSA_PhysicalPackage represents the overall physic
HP Confidential Table 15-8 Class: HPSA_PhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Version Not populated—Not available for this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HPSA_PhysicalPackage 15-3-8 HPSA_ArrayControllerPhysicalPackage HPSA_ArrayControllerPhysicalPackage represents the physical aspects of any Smart Array controller. There is one instance per HBA or one instance per controller in an external Storage subsystem.
HP Confidential Table 15-9 Class: HPSA_ArrayControllerPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation HPSA_ArrayControllerPhysicalPackage 15-3-9 HPSA_DiskPhysicalPackage HPSA_DiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive.
HP Confidential Table 15-11 Class: HPSA_StorageEnclosure (HP_StorageEnclosure) Property name Property implementation CIM_ManagedElement ElementName Port Box , where is the active port, is the passive port number and is the box number. For dual port SAS disks, both port numbers should be displayed CIM_ManagedSystemElement Name Port Box , where is the active port, is the passive port number and is the box number.
HP Confidential Table 15-12 Class: HPSA_StorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Port Box , where is the active port, is the passive port number and is the box number. For dual port SAS disks, both port numbers should be displayed CIM_ManagedSystemElement Name Opaque Key OperationalStatus[0,1, 2, 3 ] Operational status for enclosure and associated power supplies, fans and sensors.
HP Confidential 15-3-12 HPSA_PortController HPSA_PortController represent the HBA in the host system. There is one instance per HBA. This class is not implemented for external subsystems (for example, MSA500).
HP Confidential Table 15-14 Class: HPSA_DAPort (CIM_DAPort) Property name Property implementation CIM_ManagedSystemElement OperationalStatus[0] Port status: 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSA_DAPort DeviceID Opaque key SystemCreationClassName HPSA_ArraySystem SystemName HPSA_ArraySystem.
HP Confidential Table 15-15 Class: HPSA_SPIPort (CIM_SPIPort) Property name Property implementation OperationalStatus[0] Port status: 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSA_SPIPort DeviceID Opaque key SystemCreationClassName HPSA_ArraySystem SystemName HPSA_ArraySystem.
HP Confidential Table 15-16 Class: HPSA_Firmware (CIM_SoftwareIdentity) Property name Property implementation Classifications[0] 10 (Firmware) InstanceID Opaque key IsEntity False(always set to False) Manufacturer Controller vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ: (HPQ: subsystemID and VendorId combination) VersionString Controller firmware version string HPSA_Firmware 15-3-16 HPSA_EnclosureFirmware HPSA_EnclosureFirmware represents the f
HP Confidential 15-3-17 HPSA_PrimordialPool HPSA_PrimordialPool represents the total raw storage managed by the array controller. There is one instance per array system.
HP Confidential Table 15-19 Class: HPSA_StoragePool (CIM_StoragePool) Property name Property implementation PoolID Controller serial number:, where is the array number as supplied from API Primordial Always set to FALSE RemainingManagedSpace Remaining raw space in current pool TotalManagedSpace Total raw space managed by this pool HPSA_StoragePool 15-3-19 HPSA_MediaAccessStatData HPSA_MediaAccessStatData represents the Monitoring and Performance data counters on HP Disk Drives.
HP Confidential Table 15-20 Class: HPSA_MediaAccessStatData (CIM_MediaAccessStatData) Property name Property implementation NotReadyErrors See HP Smart Array Profile OtherTimeOuts See HP Smart Array Profile SCSIBusFaults See HP Smart Array Profile SectorsRead See HP Smart Array Profile SectorsWritten See HP Smart Array Profile SeekCount See HP Smart Array Profile SeekErrors See HP Smart Array Profile ServiceHours See HP Smart Array Profile SpinUpErrors See HP Smart Array Profile RetryRe
HP Confidential Table 15-21 Class: HPSA_StorageSetting (CIM_StorageSetting) Property name Property implementation DataRedundancyMin 1 (RAID 0, RAID 5, RAID 6, RAID 50) 2 (RAID 1+0) DeltaReservationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 NoSinglePointOfFailure FALSE—RAID 0 TRUE—RAID 1+0, RAID 5, RAID 6 PackageRedundancyGoal 0 (RAID 0) 1 (RAID 1+0, RAID 5) 2 (RAID 6, RAID 50) PackageRedundancyMax 0 (RAID 0) 1 (RAID 1+0, RAID 5) 2 (RAID 6, RAID 50) PackageRedunda
HP Confidential Table 15-22 Class: HPSA_DriveCage (CIM_PhysicalPackage) Property name Property implementation Model Drive Cage Model string PartNumber Not populated—Not available in this implementation Tag Opaque key SerialNumber Enclosure Serial number Version Not populated—Not available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HP_DriveCage BackplaneSpeed See profile DriveBays See profile DuplexLocation See profile Location 1 (internal), 2(Extern
HP Confidential Table 15-23 Class: HPSA_SCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation CIM_ProtocolEndpoint ProtocolIFType 0 (Unknown) CIM_SCSIProtocolEndpoint ConnectionType The supported connection type for this endpoint For example: 3(Parallel SCSI) for SCSI controllers 8(SAS) for SAS controllers 1 (Other) OtherConnectionType The connection type, if ConnectionType is "Other" Role 4 (Both Initiator and Target) HPSA_SCSIProtocolEndpoint 15-3-23 HPSA_SCSIPr
HP Confidential Table 15-24 Class: HPSA_SCSIProtocolController (CIM_SCSIProtocolController) Property name Property implementation CIM_ProtocolController MaxUnitsControlled 32 CIM_SCSIProtocolController HPSA_SCSIProtocolController 15-3-24 HPSA_RedundancySet HPSA_RedundancySet represents controller redundancy if there is more than one controller in a redundant configuration (for example, an MSA500 with two controllers.
HP Confidential Table 15-26 Class: HPSA_StorageRedundancySet (CIM_StorageRedundancySet) Property name Property implementation CIM_SystemSpecificCollection InstanceID Opaque key CIM_RedundancySet LoadBalanceAlgorithm 2 (No Load Balancing) MaxNumberSupported 0 MinNumberNeeded 0 RedundancyStatus 2 (Fully Redundant) 3 (Degraded redundancy) TypeOfSet[0] 5 (Limited Sparing) CIM_StorageRedundancySet HPSA_StorageRedundancySet 15-3-26 HPSA_StorageSpecificCollection HPSA_StorageSpecificCollection
HP Confidential 15-3-27 HPSA_DriveCageLocation HPSA_DriveCageLocation represents a location string for the drive cage.
HP Confidential Table 15-29 Class: HPSA_ArraySystemLocation (HP_Location) Property name Property implementation ElementName Controller name and location Examples: Smart Array in Slot 3, for internal MSA500 in SystemCab03, for external CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag PCI Slot Number—When ‗Adapter‘ is specified in ElementLocationTagDesc Chassis Name—When ‗Chassis‘ is specified in ElementLocationTagDesc ElementLocationTagDesc 23 (Ada
HP Confidential Table 15-30 Class: HPSA_DiskDriveLocation (HP_Location) Property name Property implementation ElementName Controller name, Drive Type and Disk Location For example, Smart Array E500 Physical Drive—Port: 1E Box 1 Bay: 5 CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number of Disk Drive— When Bay is specified in ElementLocationTagDesc.
HP Confidential Table 15-31 Class: HPSA_ArrayControllerLocation (HP_Location) Property name Property implementation Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag for Internal HBAs: PCI Slot Number Examples: 3—For adapter in PCI Slot 3 0—For Embedded adapter For external controllers: Controller number per chassis label Examples: Controller 1 Controller 2 ElementLocationTagDesc 23 (Adapter)—For internal HBAs 0 (Hood Tag)—For external controllers LocationInf
HP Confidential Table 15-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities) Property name Property implementation ElementName For Primodial Pools: Controller name and location Examples: Smart Array in Slot 3, for internal Active Controller: MSA500 in SystemCab03, for external For Concrete Pools: Controller name and location:Array identifier Examples: Smart Array in Slot 3: Array – 0, for internal Active Controller: MSA500 in SystemCab03: Array – 1, for external CIM_Capabilities Insta
HP Confidential Table 15-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities) Property name Property implementation PackageRedundancyMin 0 HPSA_StorageCapabilities 15-3-32 HPSA_Product HPSA_Product represents the top-level marketing information for the Array System.
HP Confidential Table 15-34 Class: HPSA_StorageEnclosureLocation (HP_Location) Property name Property implementation Description Enclosure location Port Box , where is the port and is the box number CIM_Location Name Key PhysicalPosition Key HP_Location Unknown for Undetermined External for external enclosures Internal for drive cages located within the host ElementLocationTag chassis ElementLocationTagDesc 15-3-34 19 (Box) HPSA_TSASSCSIProtocolEndpoint HPSA_TSASSCSIProto
HP Confidential Table 15-35 Class: HPSA_TSASSCSIProtocolEndpoint Property name Property implementation Name HPSA DiskDrive.DeviceID:unique value, where HPSA DiskDrive.DeviceID is the DeviceID property of the instance of HPSA_DiskDrive associated to this instance via the association HPSA_DiskDriveTSASSCSIPE, and unique value is a unique value across all instances of HPSA_TSASSCSIProtocolEndpoint.
HP Confidential Table 15-36 Class: HPSA_EncProtocolEndpoint Property name Property implementation CIM_ManagedElement ElementName Box where n1 is the box number relative to active port Caption Protocol Endpoint for xxx, where xxx is the value populated in the caption property of the instance of HPSA_EncSASPort associated to this instance via the association HPSA_EncSASPortEncProtocolEndPoint CIM_ManagedSystemElement Opaque Key Name CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault
HP Confidential Table 15-37 Class: HPSA_ISASSCSIProtocolEndpoint Property name Property implementation Caption Protocol Endpoint for xxx, where xxx is the value populated in the caption property of the instance of HPSA_TSASPort associated to this instance via the association HPSA_TSASPortTSASSCSIPE ElementName Protocol Endpoint for xxx, where xxx is the value populated in the caption property of the instance of HPSA_TSASPort associated to this instance via the association HPSA_TSASPortTSASSCSIPE CIM_M
HP Confidential Table 15-38 Class: HPSA_TSASPort Property name Property implementation OperationalStatus 2 (OK) For multipath supported firmware implementations, the status of the port is OK, and the status of the path is the only element that can be detected. CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice SystemnCreationClassName HPSA_ArraySystem SystemName The property value of HP_ArraySystem.
HP Confidential Table 15-38 Class: HPSA_EncSASPort Property name Property implementation OperationalStatus 2 (OK) For multipath supported firmware implementations, the status of the port is OK, and the status of the path is the only element that can be detected. CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice SystemnCreationClassName HPSA_ArraySystem SystemName The property value of HP_ArraySystem.
HP Confidential Table 15-39 Class: HPSA_ISASPort Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_LogicalDevice SystemnCreationClassName HPSA_ArraySystem SystemName The property value of HP_ArraySystem.name CreationClassName HPSA_ISASPort DeviceID HPSA PortController.DeviceIDport #, where HPSA_PortController.
HP Confidential Table 15-40 Class: HPSA_ConnectivityCollection Property name Property implementation Description "Protocol End point for Port: + + on Box: + < Box Number> + connected to + Where Cntrl DeviceID is DeviceID property of the instance of HPSA_PortController to which this enclosure Port is connected to.
HP Confidential Table 15-42 Class: HPSA_StorageVolumeStorageSetting (CIM_ElementSettingDate) Property name Property implementation SettingData HPSA_StorageSetting IsCurrent 1 (Set to Is Current) IsDefault 1 (Set to Is Default) HPSA_PrimordialPoolStorageCapabilities (Association) 15-3-43 Table 15-43 Class: HPSA_PrimordialPoolStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities HPSA_StorageCapabilities ManagedElement HPSA_PrimordialPool HPSA_StorageP
HP Confidential HPSA_ArraySystemSCSIProtocolController (Association) 15-3-46 Table 15-46 Class: HPSA_ArraySystemSCSIProtocolController (CIM_SystemDevice) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_SCSIProtocolController HPSA_ArraySystemPortController (Association) 15-3-47 Table 15-47 Class: HPSA_ArraySystemPortController (CIM_Logicaldentity) Property name Property implementation SameElement HPSA_ArraySystem SystemElement HPSA_PortController 15-3-4
HP Confidential HPSA_ArraySystemStorageExtent (Association) 15-3-50 Table 15-50 Class: HPSA_ArraySystemStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_StorageExtent 15-3-51 HPSA_ArraySystemSPIPort (Association) Table 15-51 Class: HPSA_ArraySystemSPIPort (CIM_SystemDevice) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_SPIPort.
HP Confidential Table 15-54 Class: HPSA_ArraySystemStoragePool (CIM_HostedStoragePool) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_StoragePool HPSA_ComputerSystemArraySystem (Association) 15-3-55 Table 15-55 Class: HPSA_ComputerSystemArraySystem (CIM_ComponentCS) Property name Property implementation GroupComponent HP_WinComputerSystem PartComponent HPSA_ArraySystem HPSA_ArraySystemArrayController (Association) 15-3-56 Table 15-56 Class: HPSA_Array
HP Confidential Table 15-58 Class: HPSA_ProductPhysicalPackage (CIM_ProductPhysicalPackage) Property name Property implementation GroupComponent HPSA_Product PartComponent HPSA_PhysicalPackage HPSA_StorageEnclosureDriveCage (Association) 15-3-59 Table 15-59 Class: HPSA_StorageEnclosureDriveCage (CIM_Container) Property name Property implementation GroupComponent HPSA_StorageEnclosure PartComponent HPSA_DriveCage HPSA_PhysicalPackageArrayControllerPhy sicalPackage (Association) 15-3-60 Table 1
HP Confidential Table 15-62 Class: HPSA_PhysicalPackageStorageEnclosure (CIM_Container) Property name Property implementation GroupComponent HPSA_PhysicalPackage PartComponent HPSA_StorageEnclosure HPSA_DriveCageDiskPhysicalPackage (Association) 15-3-63 Table 15-63 Class: HPSA_DriveCageDiskPhysicalPackage (CIM_Container) Property name Property implementation GroupComponent HPSA_DriveCage PartComponent HPSA_DiskPhysicalPackage HPSA_StoragePoolStorageExtent (Association) 15-3-64 Table 15-64 Cla
HP Confidential Table 15-66 Class: HPSA_StorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection HPSA_StorageSpecificCollection Member HPSA_ArraySystem HPSA_ArrayControllerRedundancySet (Association) 15-3-67 Table 15-67 Class: HPSA_ArrayControllerRedundancySet (CIM_MemberOfCollection) Property name Property implementation Collection HPSA_RedundancySet Member HPSA_ArrayController HPSA_StorageRedundancySetStorageExte nt (Association) 15-3-68
HP Confidential Table 15-70 Class: HPSA_SCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation Antecedent HPSA_SCSIProtocolController Dependent HPSA_StorageVolume DeviceAccess 2 (Read Write) DeviceNumber Device LUN number 15-3-71 HPSA_FirmwareArraySystem (Association) Table 15-71 Class: HPSA_FirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSA_Firmware Dependent HPSA_ArraySystem ElementSo
HP Confidential Table 15-73 Class: HPSA_DiskDriveDiskDriveFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) HPSA_DiskDriveStorageExtent (Association) 15-3-74 Table 15-74 Class: HPSA_DiskDriveStorageExtent (CIM_MediaPresent) Property name Property implementation Antecedent HPSA_DiskDrive Dependent HPSA_StorageExtent HPSA_DiskPhysicalPackageDiskDrive (Association) 15-3
HP Confidential HPSA_PrimordialPoolStoragePool (Association) 15-3-77 Table 15-77 Class: HPSA_PrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Property implementation Antecedent HPSA_PrimordialPool Dependent HPSA_StoragePool SpaceConsumed Bytes consumed by storage pool HPSA_SpareExtentStorageExtent (Association) 15-3-78 Table 15-78 Class: HPSA_SpareExtentStorageExtent (CIM_Spared) Property name Property implementation Antecedent HPSA_StorageExtent Dependent HPSA_StorageE
HP Confidential HPSA_DAPortSCSIProtocolEndpoint (Association) 15-3-81 Table 15-81 Class: HPSA_DAPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent HPSA_DAPort Dependent HPSA_SCSIProtocolEndpoint HPSA_SPIPortSCSIProtocolEndpoint (Association) 15-3-82 Table 15-82 Class: HPSA_SPIPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent HPSA_SPIPort Dependent HPSA_SCSIProtocolEndpoint HPSA_StorageGr
HP Confidential HPSA_ArrayControllerPhysicalPackageArr ayController (Association) 15-3-85 Table 15-85 Class: HPSA_ArrayControllerPhysicalPackageArrayController (CIM_ComputerSystemPackage) Property name Property implementation Antecedent HPSA_ArrayControllerPhysicalPackage Dependent HPSA_ArrayController HPSA_DiskDriveMediaAccessStatData (Association) 15-3-86 Table 15-86 Class: HPSA_DiskDriveMediaAccessStatData (CIM_ElementStatisticalData) Property name Property implementation ManagedElement HPSA_
HP Confidential HPSA_DriveCageDriveCageLocation (Association) 15-3-89 Table 15-89 Class: HPSA_DriveCageDriveCageLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSA_DriveCage PhysicalLocation HPSA_DriveCageLocation HPSA_DiskPhysicalPackageDiskDriveLocati on (Association) 15-3-90 Table 15-90 Class: HPSA_DiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSA_DiskPhysicalPackage PhysicalLocation HP
HP Confidential HPSA_ISASPortISASSCSIProtocolEndPoint (Association) 15-3-93 Table 15-93 Class: HPSA_ISASPortISASSCSIProtocolEndPoint (Association) Property name Property implementation Antecedent HPSA_ISASPort Dependent HPSA_ISASSCSIProtocolEndpoint HPSA_ArraySystemISASSCSIProtocolEndPoint (Association) 15-3-94 Table 15-94 Class: HPSA_ArraySystemISASSCSIProtocolEndPoint (Association) Property name Property implementation Antecedent HPSA_ArraySystem Dependent HPSA_ISASSCSIProtocolEndpoint 15
HP Confidential HPSA_ArraySystemTSASSCSIProtocolEndpoint (Association) 15-3-97 Table 15-97 Class: HPSA_ArraySystemTSASSCSIProtocolEndpoint (Association) Property name Property implementation Antecedent HPSA_ArraySystem Dependent HPSA_TSASSCSIProtocolEndpoint HPSA_TSASPortTSASSCSIProtocolEndpoint (Association) 15-3-98 Table 15-98 Class: HPSA_TSASPortTSASSCSIProtocolEndpoint (Association) Property name Property implementation Antecedent HPSA_TSASPort Dependent HPSA_TSASSCSIProtocolEndpoint 15
HP Confidential 15-3-101 HPSA_SCSIInitiatorTargetLogicalUnitPath The following class instance is created only with SAS controllers supporting multipath-supported firmware and configured in dual domain mode.
HP Confidential Table 15-104 Class: HPSA_ArraySystemConnectivityCollection (Association) Property name Property implementation Antecedent HPSA_ArraySystem Dependent HPSA_ConnectivityCollection HPSA_StorageEnclosureEncProtocolEndPoint (Association) 15-3-105 Table 15-105 Class: HPSA_StorageEnclosureEncProtocolEndpoint Property name Property implementation AvailableSAP HPSA_EncProtocolEndpoint ManagedElement HPSA_StorageEnclosure HPSA_ISASSCSIProtocolEndpointConnect ivityCollection (Association)
HP Confidential Table 15-108 Class: HPSA_ArraySystemExternalArraySystem (Association) Property name Property implementation GroupComponent HPSA_ArraySystem PartComponent HPSA_ArraySystem 15-3-109 HPSA_CacheVolumeStorageVolume (Association) Table 15-108 Class: HPSA_CacheVolumeStorageVolume (Association) 15-4 Property name Property implementation Antecedent HPSA_StorageVolume Dependent HPSA_StorageVolume Supported indications Physical Drive Status Changed to OK 15-4-1 Table 15-39 HPSA_Devic
HP Confidential Table 15-39 HPSA_DeviceIndication: Physical Drive status changed to OK Property name Property implementation RecommendedActions No action is recommended.
HP Confidential Table 15-39 HPSA_DeviceIndication: Physical Drive status changed to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 15-40 HPSA_DeviceIndication: Physical Drive status changed to ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A Physical Drive status has changed to ERROR status.
HP Confidential Table 15-40 HPSA_DeviceIndication: Physical Drive status changed to ERROR Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames VariableNames[0]: FailureDescription VariableNames[1]: LastFailureDescription VariableNames[2]: DriveInterface VariableTypes Var
HP Confidential Table 15-40 HPSA_DeviceIndication: Physical Drive status changed to ERROR Property name Property implementation HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) DeviceControllerLogicalLocation Controller Location For example, SmartArray 642 in Slot 2 HWManufacturer HP HWSerialNumber Physical Disk Serial Number HP_DeviceIndication DeviceModel Physical Disk Model string Physical Drive Status Changed to REBUILDING 15-4-3 Table 15-41 HPSA_DeviceIndication: Phy
HP Confidential Table 15-41 HPSA_DeviceIndication: Physical Drive status changed to REBUILDING Property name Property implementation NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, <
HP Confidential Table 15-41 HPSA_DeviceIndication: Physical Drive status changed to REBUILDING Property name Property implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the S
HP Confidential Table 15-42 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE Property name Property implementation AlertingMangedElement WBEM path of the HPSA_DiskDrive class AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 204 ProviderName HP Smart Array RecommendedActions Replace drive immediately to avoid loss of data SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the compu
HP Confidential Table 15-42 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE Property name Property implementation VariableTypes VariableTypes[0]: 1 (String) VariableTypes[1]: 1 (String) VariableTypes[2]: 4 (uint16)) VariableValues VariableValues[0]: Short Description of failure VariableValues[1]: Short Description of last failure VariableValues[2]: HPSA_DiskDrive.
HP Confidential 15-4-5 Physical Drive Status Secure Erase State Table 15-43 HPSA_DeviceIndication: Physical Drive status changed to Secure Erase State Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Degraded) IndicationTime Time of indication CIM_AlertIndication Description A Physical Drive is Currently Offline but operational, Secure Erase is in Progress.
HP Confidential Table 15-43 HPSA_DeviceIndication: Physical Drive status changed to Secure Erase State Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer
HP Confidential Table 15-43 HPSA_DeviceIndication: Physical Drive status changed to Secure Erase State Property name Property implementation HWFirmwareVersion Physical Disk firmware version string HWLogicalLocation Physical Disk Location string For example, Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) DeviceControllerLogicalLocation Controller Location For example, SmartArray 642 in Slot 2 HWManufacturer HP HWSerialNumber Physical Disk Serial Numbe
HP Confidential Table 15-44 HPSA_DeviceIndication: Physical Drive status changed to OK Property name Property implementation EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of
HP Confidential Table 15-44 HPSA_DeviceIndication: Physical Drive status changed to OK Property name Property implementation EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE Property name Property implementation Description Due to Solid State wear out a physical drive status has changed to Predictive Failure .
HP Confidential Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE Property name Property implementation VariableNames VariableNames[0]: FailureDescription VariableNames[1]: LastFailureDescription VariableNames[2]: DriveInterface VariableTypes VariableTypes[0]: 1 (String) VariableTypes[1]: 1 (String) VariableTypes[2]: 4 (uint16)) VariableValues VariableValues[0]: Short Description of failure VariableValues[1]: Short Description of last failure V
HP Confidential Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE Property name Property implementation HP_DeviceIndication DeviceModel Physical Disk Model string Physical drive status warning for Smart Drive Not Authentication 15-4-8 Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Degraded) Indicati
HP Confidential Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to Degraded Property name Property implementation OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, .. ProviderVersion Provider version generating the indication in the format, ..
HP Confidential Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to Degraded Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate pr
HP Confidential Table 15-114 HPSA_StorageVolumeIndication: Logical Drive status changed to OK Property name Property implementation AlertType 5 (Device Alert) EventID 101 ProviderName HP Smart Array RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Logical Drive Status OK EventCategory 6 (Primary Storage) ProbableC
HP Confidential Table 15-114 HPSA_StorageVolumeIndication: Logical Drive status changed to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential 15-4-10 Logical Drive Status Changed to ERROR Table 15-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A Logical Drive Status has changed to Error .
HP Confidential Table 15-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String)
HP Confidential Table 15-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR Property name Property implementation DeviceOperationalStatus Current OperationStatus values for Storage Volume DeviceOperationalStatus[0]: HPSA_StorageVolume.OperationalStatus[0] DeviceOperationalStatus[1]: HPSA_StorageVolume.
HP Confidential Table 15-116 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Logical Drive in degraded state.
HP Confidential Table 15-116 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductMo
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded - multipath failure Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Degraded) IndicationTime Time of indication CIM_AlertIndication Description A logical drive is in a degraded state. Multipath support is Lost. Either cable is removed or not configured.
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded - multipath failure Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure ImpactedDomain
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded - multipath failure Property name Property implementation DeviceOperationalStatus Current OperationStatus values for Storage Volume DeviceOperationalStatus[0]: HPSA_StorageVolume.OperationalStatus[0] DeviceOperationalStatus[1]: HPSA_StorageVolume.
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Expanding Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Logical drive in expanding state.
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Expanding Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductM
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Queued for Expansion Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Degraded) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed to Queued for Expansion.
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Queued for Expansion Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure ImpactedDomain 3 (En
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Queued for Expansion Property name Property implementation DeviceOperationalStatus Current OperationStatus values for Storage Volume DeviceOperationalStatus[0]: HPSA_StorageVolume.OperationalStatus[0] DeviceOperationalStatus[1]: HPSA_StorageVolume.
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Not Yet Available Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Logical drive in not yet available state.
HP Confidential Table 15-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Not Yet Available Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment Solution
HP Confidential Table 15-118 HPSA_DeviceIndication: Controller status changed to OK Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description Array Controller Status has changed to a status of OK. AlertingMangedElement WBEM path to the HPSA_ArrayController class.
HP Confidential Table 15-118 HPSA_DeviceIndication: Controller status changed to OK Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication VariableNames VariableNames[0]: FailureDescription VariableNames[1]: CacheSizeTotal VariableNames[2]:CacheSerialNumber VariableTypes VariableTypes[0]: 1 (String) VariableTypes[1]: 5 (uint16) VariableTypes[2]: 1 (String) VariableValues VariableValues[0]: Short Description of failure Variabl
HP Confidential Table 15-118 HPSA_DeviceIndication: Controller status changed to OK Property name Property implementation HP_DeviceIndication DeviceModel Array Controller Model string 15-4-17 Controller Status Changed to ERROR Table 15-119 HPSA_DeviceIndication: Controller status changed to ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Descrip
HP Confidential Table 15-119 HPSA_DeviceIndication: Controller status changed to ERROR Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, .. ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 15-119 HPSA_DeviceIndication: Controller status changed to ERROR Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 15-120 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Controller Redundancy State has been set to Active EventCategory 6 (Primary Storage) ProbableCause 0 NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType
HP Confidential Table 15-120 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 15-121 HPSA_DeviceIndication: Controller Redundancy has been lost Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description Controller has detected that Redundancy has been lost due to failure or loss of communication with partner controller. AlertingMangedElement WBEM path to the HPSA_ArrayController class.
HP Confidential Table 15-121 HPSA_DeviceIndication: Controller Redundancy has been lost Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication VariableNames VariableNames[0]: FailureDescription VariableNames[1]: CacheSizeTotal VariableNames[2]: CacheSerialNumber VariableTypes VariableTypes[0]: 1 (String) VariableTypes[1]: 5 (uint16) VariableTypes[2]: 1 (String) VariableValues VariableValues[0]: Short Description of failure Va
HP Confidential Table 15-121 HPSA_DeviceIndication: Controller Redundancy has been lost Property name Property implementation HP_DeviceIndication DeviceModel Array Controller Model string 15-4-20 Controller Redundancy has been restored Table 15-122 HPSA_DeviceIndication: Controller Redundancy has been restored Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndica
HP Confidential Table 15-122 HPSA_DeviceIndication: Controller Redundancy has been restored Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, .. ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 15-122 HPSA_DeviceIndication: Controller Redundancy has been restored Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 15-123 HPSA_DeviceIndication: Controller Battery status changed to OK Property name Property implementation HP_AlertIndication Summary Controller battery status change to OK EventCategory 6 (Primary Storage) ProbableCause 0 NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For W
HP Confidential Table 15-123 HPSA_DeviceIndication: Controller Battery status changed to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 15-124 HPSA_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description Controller Battery Status is set to Not fully charged. AlertingMangedElement WBEM path to the HPSA_ArrayController class.
HP Confidential Table 15-124 HPSA_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames VariableNames[0]: FailureDescription VariableNames[1]: CacheSizeTotal VariableNames[2]: CacheSerialNumber VariableTypes VariableTypes[0]: 1 (String) VariableTypes[1]: 5 (uint16) Variabl
HP Confidential Table 15-124 HPSA_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation HWSerialNumber Array Controller Serial Number HP_DeviceIndication DeviceModel Array Controller Model string 15-4-23 Controller Battery Status Changed to FAILED Table 15-125 HPSA_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication Perc
HP Confidential Table 15-125 HPSA_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, .. ProviderVersion Provider version generating the indication in the format, ..
HP Confidential Table 15-125 HPSA_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the
HP Confidential Table 15-126 HPSA_DeviceIndication: Controller Cache status changed to OK Property name Property implementation ProviderName HP Smart Array RecommendedActions No action is recommended SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Array Controller Cache Status changed to OK.
HP Confidential Table 15-126 HPSA_DeviceIndication: Controller Cache status changed to OK Property name Property implementation VariableValues VariableValues[0]: Short Description of failure VariableValues[1]: HPSA_ArrayController.CacheSizeTotal VariableValues[2]: HPSA_ArrayController.CacheSerialNumber ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
HP Confidential Table 15-127 HPSA_DeviceIndication: Controller Cache status—Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array Controller Cache status has changed to Degraded. AlertingMangedElement WBEM path to the HPSA_ArrayController class.
HP Confidential Table 15-127 HPSA_DeviceIndication: Controller Cache status—Degraded Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames VariableNames[0]: FailureDescription VariableNames[1]: CacheSizeTotal VariableNames[2]: CacheSerialNumber VariableTypes VariableTypes
HP Confidential Table 15-127 HPSA_DeviceIndication: Controller Cache status—Degraded Property name Property implementation HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 HWManufacturer Array Controller Manufacturer string HWSerialNumber Array Controller Serial Number HP_DeviceIndication DeviceModel Array Controller Model string 15-4-26 Controller Cache Status - Failed Table 15-128 HPSA_DeviceIndication: Controller Cache status—Failed Property name Pr
HP Confidential Table 15-128 HPSA_DeviceIndication: Controller Cache status—Failed Property name Property implementation NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, .
HP Confidential Table 15-128 HPSA_DeviceIndication: Controller Cache status—Failed Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional
HP Confidential Table 15-129 HPSA_DeviceIndication: Controller Cache status—Not Configured Property name Property implementation AlertType 5 (Device Alert) EventID 12 ProviderName HP Smart Array RecommendedActions Check the cache controller error code and run diagnostics.
HP Confidential Table 15-129 HPSA_DeviceIndication: Controller Cache status—Not Configured Property name Property implementation VariableTypes VariableTypes[0]: 1 (String) VariableTypes[1]: 5 (uint16) VariableTypes[2]: 1 (String) VariableValues VariableValues[0]: Short Description of failure VariableValues[1]: HPSA_ArrayController.CacheSizeTotal VariableValues[2]: HPSA_ArrayController.
HP Confidential Enclosure Power Supply Status Changed to Non Redundant 15-4-28 Table 15-130 HPSA_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem status has changed to non-redundant AlertingMangedElement WBEM path of the HPSA_Storage
HP Confidential Table 15-130 HPSA_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the compu
HP Confidential Enclosure Power Supply Status Changed to OK (Redundant) 15-4-29 Table 15-131 HPSA_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Supply has changed to Fully Redundant AlertingMangedElement WBEM path of the HPSA_StorageEnclosure
HP Confidential Table 15-131 HPSA_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the comp
HP Confidential Enclosure Power Supply Status Changed to Redundant Degraded 15-4-30 Table 15-132 HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Supply status has changed to Degraded Redundancy.
HP Confidential Table 15-132 HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 15-132 HPSA_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation HP_DeviceIndication DeviceModel Enclosure Model string Enclosure Temperature sensor status changed to OK 15-4-31 Table 15-133 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime
HP Confidential Table 15-133 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, .. ProviderVersion Provider version generating the indication in the format, ..
HP Confidential Table 15-133 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 15-134 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor Status changed to Warning Condition.
HP Confidential Table 15-134 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 15-135 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 309 ProviderName HP Smart Array RecommendedActions Verify fan and power supply operation for enclosure. Verify ambient room temperature is within guidelines.
HP Confidential Table 15-135 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 15-136 HPSA_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation Description A Storage Enclosure Fan status has changed from a non-OK state to OK.
HP Confidential Table 15-136 HPSA_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation VariableTypes 1 (String) VariableValues Short description of failure ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 15-137 HPSA_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status has changed to Degraded.
HP Confidential Table 15-137 HPSA_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short description of failure ImpactedDomain 3 (Enclosure) for c-Clas
HP Confidential Table 15-138 HPSA_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description Enclosure Fan Status changed to a status of Failure. Enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.
HP Confidential Table 15-138 HPSA_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) Varia
HP Confidential 16 SAS HBA 16-1 Overview The HP SAS HBA Profile describes host-based SAS HBA providers. The following table details the profiles implemented and files installed by this provider. Table 16-1 Overview 16-2 Implemented Profiles HP SAS HBA Provider Installation Files HPWMISAS.dll HPWMISASEventMsg.dll Cpqmdisk.dll Cpqmscsi.dll Cpqmsas.dll Cpqstmsg.dll Cpqstmsg.dll Cpqstrutl.dll HPWMISRV.exe Hpwmistor.exe HPWMISAS.mof HPWMISASEvent.mof HPWMISASRegistration.
HP Confidential HPSAS_ArraySystem represents the top-level system. There is one instance per HBA. Table 16-2 Class: HPSAS_ArraySystem (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement Name Controller Serial Number OperationalStatus[0] Overall status of the Array System and attached devices.
HP Confidential Table 16-3 Class: HPSAS_ArrayController (CIM_ComputerSystem) Property name Property implementation ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement Name Controller Serial Number OperationalStatus[0] Status for Array Controller 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System Cr
HP Confidential Table 16-4 Class: HPSAS_StorageVolume (CIM_StorageVolume) Property name Property implementation OperationalStatus[0] Volume status 0 (Unknown) 2 (OK) 3 (Degraded) - RAID redundancy lost or rebuilding data 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSAS_StorageVolume DeviceID Opaque Key SystemCreationClassName HPSAS_ArraySystem
HP Confidential Table 16-4 Class: HPSAS_StorageVolume (CIM_StorageVolume) Property name Property implementation HP_Storagevolume Deleteable See HP SAS HBA Profile FaultTolerance See HP SAS HBA Profile OSName Corresponding OS name for this volume HPSAS_Storagevolume HPSAS_DiskDrive 16-3-4 HPSAS_DiskDrive represents the hard drives connected to SAS HBA controllers.
HP Confidential Table 16-5 Class: HPSAS_DiskDrive (CIM_DiskDrive) Property name Property implementation SystemName HPSAS_ArraySystem.
HP Confidential HPSAS_StorageExtent 16-3-5 HPSAS_StorageExtent represents the consumable storage that is available on a disk drive. There is one instance per disk drive.
HP Confidential Table 16-6 Class: HPSAS_StorageExtent (CIM_StorageExtent) Property name Property implementation OSName Corresponding OS name for drives that are not part of RAID set HPSAS_StorageExtent HPSAS_DiskDriveFirmware 16-3-6 HPSAS_DiskDriveFirmware represents the firmware installed on a disk drive. There is one instance per disk drive.
HP Confidential HPSAS_PhysicalPackage represents the overall physical package for the HBA as a whole. There is one instance per HBA.
HP Confidential Table 16-9 Class: HPSAS_DiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Manufacturer Drive vendor string Model Drive model string PartNumber N/A—Not available in this implementation SerialNumber Drive serial number Tag Controller Serial number (SerialNumber: PhysicalDriveDeviceNumber) Version N/A—Not available in this implementation CIM_PhysicalPackage HotSwappable true—Drive is hot swappable false—Drive is not hot swappable RemovalConditi
HP Confidential Table 16-10 Class: HPSAS_PortController (CIM_PortController) Property name Property implementation SystemCreationClassName HPSAS_ArraySystem SystemName HPSAS_ArraySystem.Name CIM_Controller CIM_PortController ControllerType 1 (Other) OtherControllerType SAS/SATA HPSAS_PortController 16-3-10 HPSAS_DAPort HPSAS_DAPort represents the front-end port for an HBA in the host system.
HP Confidential Table 16-11 Class: HPSAS_DAPort (CIM_DAPort) Property name Property implementation PortType 82 (PCI) UsageRestriction 2 (Front-End Only) CIM_DAPort HPSAS_DAPort 16-3-11 HPSAS_Firmware HPSAS_Firmware represents the firmware installed on a SAS HBA controller.
HP Confidential HPSAS_PrimordialPool represents the total raw storage managed by the array controller that is assigned to RAID volumes. Table 16-13 Class: HPSAS_PrimordialPool (CIM_StoragePool) Property name Property implementation CIM_ManagedElement ElementName Controller name and location: pool identifier.
HP Confidential Table 16-14 Class: HPSAS_PrimordialPoolNoRaid (CIM_StoragePool) Property name Property implementation RemainingManagedSpace 0 TotalManagedSpace Total raw space available to controller. This is calculated by summing the total space on all non raid drives connected to this controller. HPSAS_PrimordialPoolNoRaid 16-3-14 HPSAS_StoragePool HPSAS_StoragePool represents any concrete storage pools created on an array controller. There is one instance per HBA for this implementation.
HP Confidential Table 16-16 Class: HPSAS_StorageSetting (CIM_StorageSetting) Property name Property implementation ElementName RAID , where is the raid description RAID 0 RAID 1 CIM_SettingData InstanceID Opaque key CIM_StorageSetting ChangeableType 0 (Not Changeable) DataRedundancyGoal 1 (RAID 0) 2 (RAID 1) DataRedundancyMax 1 (RAID 0) 2 (RAID 1) DataRedundancyMin 1 (RAID 0) 2 (RAID 1) DeltaReservationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 NoSinglePoi
HP Confidential Table 16-17 Class: HPSAS_SCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation CIM_ManagedSystemElement Name HBA Serial Number CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint CreationClassName HPSAS_SCSIProtocolEndpoint SystemCreationClassName HPSAS_ArraySystem SystemName HPSAS_ArraySystem.
HP Confidential Table 16-18 Class: HPSAS_SCSIProtocolController (CIM_SCSIProtocolController) Property name Property implementation EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSAS_SCSIProtocolController DeviceID Opaque key SystemCreationClassName HPSAS_ArraySystem SystemName HPSAS_ArraySystem.
HP Confidential Table 16-19 Class: HPSAS_StorageRedundancySet (CIM_StorageRedundancySet) Property name Property implementation HPSAS_StorageRedundancySet 16-3-19 HPSAS_StorageSpecificCollection HPSAS_StorageSpecificCollection represents a collection of SAS HBA controllers that are grouped together to report consolidated status.
HP Confidential Table 16-21 Class: HPSAS_ArraySystemLocation (HP_Location) Property name Property implementation ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_Location Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag PCI Slot number ElementLocationTagDesc 23 (Adapter) LocationInformation PCI Slot number For example, 3—PCI Slot 3 LocationInfoDesc 3 (PCI Slot) HPSAS_ArraySystemLocation 16-3-21 HPSAS_DiskDriveLocation
HP Confidential Table 16-22 Class: HPSAS_DiskDriveLocation (HP_Location) Property name Property implementation HPSAS_DiskDriveLocation 16-3-22 HPSAS_StorageCapabilities HPSAS_StorageCapabilities represents the possible capabilities of a Storage Pool.
HP Confidential Table 16-23 Class: HPSAS_StorageCapabilities (CIM_StorageCapabilities) Property name Property implementation NoSinglePointOfFailureDefault True—When number of drives > 1 (For example, Pool can be configured for redundancy.
HP Confidential Table 16-25 Class: HPSAS_DriveCage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Port Box , where is the name of the port this drive cage is connected and is the Box Number For example, Port IE Box 1 CIM_ManagedSystemElement Name Serial Number of drive cage N/A—when serial number is not available CIM_PhysicalElement CreationClassName HPSAS_DriveCage Manufacturer Drive Cage Vendor string Model Drive Cage Model string Par
HP Confidential Table 16-26 Class: HPSAS_EnclosureFirmware (CIM_SoftwareIdentity) Property name Property Implemenation CIM_ManagedSystemElement Name Storage Enclosure Firmware CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure Vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ: VersionString Enclosure firmware string HPSAS_Enclos
HP Confidential Table 16-27 Class: HPSAS_StorageEnclosure (HP_StorageEnclosure) Property name Property implementation SerialNumber Enclosure Serial Number N/A is reported if there is no serial number (for example, internal enclosures).
HP Confidential Table 16-28 Class: HPSAS_StorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation OperationalStatus[0,1, 2, 3 ] Operational status for enclosure and associated power supplies, fans, and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile.
HP Confidential Table 16-29 Class: HPSAS_StorageEnclosureLocation (HP_Location) Property name Property implementation ElementName Enclosure location For example, Port 1E Box 1 Caption Enclosure location For example, Port 1E Box 1 Description Enclosure location For example, Port 1E Box 1 CIM_Location Name Key PhysicalPosition Key HP_Location ElementLocationTag Unknown for Undetermined External for external enclosures Internal for drive cages located within the host chassis ElementLocatio
HP Confidential HPSAS_StorageEnclosureEnclosureLocation (Association) 16-3-31 Table 16-32 Class: HPSAS_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSAS_StorageEnclosure PhysicalLocation HPSAS_StorageEnclosureLocation HPSAS_ArraySystemStorageEnclosureProcessor (Association) 16-3-32 Table 16-33 Class: HPSAS_ArraySystemStorageEnclosureProcessor (CIM_SystemComponent) Property name Property implementation GroupComponent HPSAS_ArrayS
HP Confidential Table 16-35 Class: HPSAS_StorageEnclosureStorageEnclosureProcessor (CIM_systemPackaging) Property name Property implementation Antecedent HPSAS_StorageEnclosure Dependent HPSAS_StorageEnclosureProcessor HPSAS_StorageVolumeStorageSetting (Association) 16-3-35 Table 16-36 Class: HPSAS_StorageVolumeStorageSetting (CIM_ElementSettingData) Property name Property implementation ManagedElement HPSAS_StorageVolume SettingData HPSAS_StorageSetting IsCurrent 1 (Is Current) IsDefault
HP Confidential HPSAS_StoragePoolStorageCapabilities (Association) 16-3-38 Table 16-39 Class: HPSAS_StoragePoolStorageCapabilities (CIM_ElementCapabilities ) Property name Property implementation Capabilities HPSAS_StorageCapabilities ManagedElement HPSAS_StoragePool HPSAS_ArraySystemSCSIProtocolController (Association) 16-3-39 Table 16-40 Class: HPSAS_ArraySystemSCSIProtocolController (CIM_SystemDevice) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPS
HP Confidential Table 16-43 Class: HPSAS_ArraySystemStorageVolume (CIM_SystemDevice) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_StorageVolume 16-3-43 HPSAS_ArraySystemStorageExtent (Association) Table 16-44 Class: HPSAS_ArraySystemStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_StorageExtent 16-3-44 HPSAS_ArraySystemDAPort (Association) Table 16-45 Class: HPSAS_ArraySy
HP Confidential Table 16-47 Class: HPSAS_ArraySystemPrimordialPoolNoRaid (CIM_HostedStoragePool) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_PrimordialPoolNoRaid 16-3-47 HPSAS_ArraySystemStoragePool (Association) Table 16-48 Class: HPSAS_ArraySystemStoragePool (CIM_HostedStoragePool) Property name Property implementation GroupComponent HPSAS_ArraySystem PartComponent HPSAS_StoragePool HPSAS_ComputerSystemArraySystem (Association) 16-3-48 Table
HP Confidential Table 16-51 Class: HPSAS_ProductPhysicalPackage (CIM_ProductPhysicalPackage) Property name Property implementation GroupComponent HPSAS_Product PartComponent HPSAS_PhysicalPackage 16-3-51 HPSAS_StoragePoolStorageExtent (Association) Table 16-52 Class: HPSAS_StoragePoolStorageExtent (CIM_ConcreteComponent) Property name Property implementation GroupComponent HPSAS_StoragePool PartComponent HPSAS_StorageExtent HPSAS_PrimordialPoolNoRaidStorageExtent (Association) 16-3-52 Table
HP Confidential Table 16-55 Class: HPSAS_StorageRedundancySetStorageExtent (CIM_MemberOfCollection) Property name Property implementation Collection HPSAS_StorageRedundancySet Member HPSAS_StorageExtent 16-3-55 HPSAS_ArraySystemFirmware (Association) Table 16-56 Class: HPSAS_ArraySystemFirmware (CIM_InstalledSoftwareIdentity) Property name Property implementation InstalledSoftware HPSAS_Firmware System HPSAS_ArraySystem HPSAS_SCSIProtocolControllerStorageVolume (Association) 16-3-56 Table 1
HP Confidential 16-3-58 HPSAS_DiskDriveDiskDriveFirmware (Association) Table 16-59 Class: HPSAS_DiskDriveDiskDriveFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSAS_DiskDriveFirmware Dependent HPSAS_DiskDrive ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) HPSAS_DiskPhysicalPackageDiskDrive (Association) 16-3-59 Table 16-60 Class: HPSAS_DiskPhysicalPackageDiskDrive (CIM_Realizes) Property name Pr
HP Confidential HPSAS_SpareExtentStorageRedundancySet (Association) 16-3-62 Table 16-63 Class: HPSAS_SpareExtentStorageRedundancySet (CIM_IsSpare) Property name Property implementation Antecedent HPSAS_StorageExtent Dependent HPSAS_StorageRedundancySet HPSAS_StorageExtentStorageVolume (Association) 16-3-63 Table 16-64 Class: HPSAS_StorageExtentStorageVolume (CIM_BasedOn) Property name Property implementation Antecedent HPSAS_StorageExtent Dependent HPSAS_StorageVolume HPSAS_DAPortSCSIProtoc
HP Confidential HPSAS_PhysicalPackageArraySystem (Association) 16-3-66 Table 16-67 Class: HPSAS_PhysicalPackageArraySystem (CIM_ComputerSystemPackage) Property name Property implementation Antecedent HPSAS_PhysicalPackage Dependent HPSAS_ArraySystem HPSAS_PhysicalPackageArraySystemLocation (Association) 16-3-67 Table 16-68 Class: HPSAS_PhysicalPackageArraySystemLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSAS_PhysicalPackage Physical Location HPSAS_A
HP Confidential 2-3-70 HPSAS_SmartDriveCarrierAppFirmware HPSAS_SmartDriveCarrierAppFirmware represents the Smart Drive carrier firmware installed on a disk drive. There is one instance per disk drive. Instances of these classes will be available only when the drive supports Authentication.
HP Confidential Table 16-722 Class: HPSAS_SmartDriveCarrierBootldrFirmware (CIM_SoftwareIdentity) Property name Property implementation Caption Smart Drive carrier boot loader Firmware Description Smart Drive carrier boot loader Firmware ElementName TargetType value CIM_ManagedSystemElement Name Smart Drive carrier Bootloader Firmware CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions[0] Smart Drive carrier Bootloader Firmware Classifications[0] 10 (Firmware) InstanceID Opaqu
HP Confidential Table 16-74 Class: HPSAS_SmartDrvCarrierAppElementFirmwareIdentity (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSAS_SmartDriveCarrierAppFirmware Dependent HPSAS_DiskDrive HPSAS_SmartDrvCarrierAppInstalledFirmw areIdentity (Association) 2-3-74 Table 16-75 Class: HPSAS_SmartDrvCarrierAppInstalledFirmwareIdentity (CIM_InstalledSoftwareIdentity ) Property name Property name Antecedent HPSAS_SmartDriveCarrierAppFirmware Dependent HPSAS_ArraySystem
HP Confidential Table 16-77 HPSAS_DeviceIndication: SAS HBA status OK Property name Property implementation IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A SAS/SATA HBA status has changed from non-OK to OK.
HP Confidential Table 16-77 HPSAS_DeviceIndication: SAS HBA status OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other syste
HP Confidential Table 16-78 HPSAS_DeviceIndication: SAS HBA in Error state Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity Severity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A SAS/SATA HBA status has changed to Error.
HP Confidential Table 16-78 HPSAS_DeviceIndication: SAS HBA in Error state Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indica
HP Confidential 2-4-3 Physical Drive Status OK Table 16-79 HPSAS_DeviceIndication: Physical Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed from non-OK to OK.
HP Confidential Table 16-79 HPSAS_DeviceIndication: Physical Drive status OK Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indi
HP Confidential Table 16-79 HPSAS_DeviceIndication: Physical Drive status OK Property name Property implementation HWLogicalLocation Disk Location string For example, Bay 3 HWManufacturer Disk Manufacturer string HWSerialNumber Disk Serial Number HP_DeviceIndication DeviceModel 2-4-4 Disk Model string Physical Drive status ERROR Table 16-80 HPSAS_DeviceIndication: Physical Drive status ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the
HP Confidential Table 16-80 HPSAS_DeviceIndication: Physical Drive status ERROR Property name Property implementation ProbableCauseDescription Physical Drive Status Changed to Error ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 16-80 HPSAS_DeviceIndication: Physical Drive status ERROR Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environm
HP Confidential Table 16-81 HPSAS_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
HP Confidential Table 16-81 HPSAS_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or ―‖ values. ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
HP Confidential Table 16-82 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Predictive Failure.
HP Confidential Table 16-82 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValue
HP Confidential Table 16-82 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation HP_DeviceIndication DeviceModel 2-4-7 Disk Model string Physical Drive status Predictive Failure – Solid State Wear out Table 16-83 HPSAS_DeviceIndication: Drive status Predictive Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 5 (Major) IndicationTime Time of indication CIM_A
HP Confidential Table 16-83 HPSAS_DeviceIndication: Drive status Predictive Failure Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 16-83 HPSAS_DeviceIndication: Drive status Predictive Failure Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 16-84 HPSAS_DeviceIndication: Drive status Degraded Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Replace drive immediately to avoid loss of data. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical drive status Degraded.
HP Confidential Table 16-84 HPSAS_DeviceIndication: Drive status Degraded Property name Property implementation VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or ―‖ values. 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems ImpactedDomain When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
HP Confidential Table 16-85 HPSAS_DeviceIndication: Logical Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed from non-OK to OK.
HP Confidential Table 16-85 HPSAS_DeviceIndication: Logical Drive status OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other
HP Confidential Table 16-86 HPSAS_DeviceIndication: Logical Drive status ERROR Property name Property implementation Description A logical drive status has changed to Error. AlertingMangedElement WBEM Path of Storage Volume AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 102 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check for failed or removed physical drives.
HP Confidential Table 16-86 HPSAS_DeviceIndication: Logical Drive status ERROR Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. 2-4-11 BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
HP Confidential Table 16-87 HPSAS_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation AlertType 5 (Device Alert) EventID 103 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check status of physical drives. Degraded status may be caused by failed or missing physical drives, or a data recovery operation on one or more physical drives.
HP Confidential Table 16-87 HPSAS_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. 2-4-12 BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 16-88 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation EventID 301 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add or replace power supplies as necessary.
HP Confidential Table 16-88 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or ―‖ values. ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.
HP Confidential Table 16-89 HPSAS_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Supply has changed to Fully Redundant.
HP Confidential Table 16-89 HPSAS_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1
HP Confidential 2-4-14 Enclosure Power Supply Status changed to Redundant Degraded Table 16-90 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Supply status has changed to Degraded Redundancy.
HP Confidential Table 16-90 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion The operating system version of the computer system generating the indication in the format: ..
HP Confidential Table 16-90 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 16-91 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation HP_AlertIndication Summary Temperature sensor status OK EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Temperature Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windo
HP Confidential Table 16-91 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 16-92 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 308 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
HP Confidential Table 16-92 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or ―‖ values.
HP Confidential Table 16-93 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status has changed to Critical. An enclosure temperature is reaching the maximum allowed temperature for normal operation.
HP Confidential Table 16-93 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation OSVersion The operating system version of the computer system generating the indication in the format: .. ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 16-93 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation HP_HardwareIndication HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel 2-4-18 Enclosure Model string Enclosure Fan Status Changed to OK Table 16-94 HPSAS_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation CIM_Indication I
HP Confidential Table 16-94 HPSAS_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation ProbableCauseDescription Fan Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion The operating system version of the computer s
HP Confidential Table 16-94 HPSAS_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product e
HP Confidential Table 16-95 HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
HP Confidential Table 16-95 HPSAS_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 16-96 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation Description A Storage Enclosure Fan Status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.
HP Confidential Table 16-96 HPSAS_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues c
HP Confidential 17 SCSI HBA 17-1 Overview The HP SCSI HBA data sheet describes the implementation of SCSI HBAs and iSCSI Initiator in a host system. The following profiles are implemented, and the following files are installed by this provider. Table 17-1 Overview 17-2 Implemented Profiles HP SCSI HBA Profile Provider Installation Files HPWMISCSI.dll HPWMISCSIEventMsg.dll Cpqmdisk.dll Cpqmscsi.dll Cpqmsas.dll Cpqstmsg.dll Cpqstmsg.dll Cpqstrutl.dll HPWMISRV.
HP Confidential Table 17-2 Class: HPSCSI_HBAComputerSystem (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller name and location (for example, SCSI Controller Port 1 in Slot 4) for SCSI controller Controller name (for example, iSCSI Initiator) for iSCSI Initiator CIM_ManagedSystemElement Name Key: HBA index for SCSI Controller Key: ElementName : Initiator InstanceID for iSCSI Initiator OperationalStatus Overall status of the system StatusDesc
HP Confidential Table 17-3 Class: HPSCSI_StorageVolume (CIM_StorageVolume) Property name Property implementation CIM_ManagedElement ElementName Volume name (for example, Disk 3) CIM_ManagedSystemElement Name SerialNumber + Vendor + Model (for example, 1020305+COMPAQ+ BD03685A24) OperationalStatus[0] Volume status StatusDescriptions 0 (Other) 2 (OK) 5 (Predictive Failure) 6 (ERROR) Description about the OperationalStatus CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enab
HP Confidential Table 17-3 Class: HPSCSI_StorageVolume (CIM_StorageVolume) Property name Property implementation HP_Storagevolume Deleteable FALSE PercentComplete 0 HPSCSI_Storagevolume OSName 17-3-3 Corresponding OS name for this volume (for example, Disk 3) HPSCSI_DiskDrive HPSCSI_DiskDrive represents the hard drives connected to SCSI HBA controllers.
HP Confidential Table 17-4 Class: HPSCSI_DiskDrive (CIM_DiskDrive) Property name Property implementation HP_DiskDrive DriveConfiguration 4 (Non RAID) DriveHasMNPData True—drive can report MNP Data False—drive does not report MNP Data DriveInterface 1 (Parallel SCSI) DrivePlacement 0 (Unknown)—drive placement cannot be determined 1 (Internal)—drive is internal to host 2 (External)—drive is contained in external enclosure DriveRotationalSpeed Speed in rpm NegotiatedDataWidth Bus width
HP Confidential Table 17-5 Class: HPSCSI_StorageExtent (CIM_StorageExtent) Property name Property implementation EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPSCSI_StorageExtent DeviceID Opaque ID SystemCreationClassName HPSCSI_HBAComputerSystem SystemName HBA index CIM_StorageExtent 17-3-5 BlockSize Block size in bytes ConsumableBlocks Total number of blocks on drive ExtentStatus 2 (None) NumberOfB
HP Confidential Table 17-6 Class: HPSCSI_DiskDriveFirmwareIdentity (CIM_SoftwareIdentity) 17-3-6 Property name Property implementation IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ: - drive model string VersionString Drive firmware string HPSCSI_HBAPhysicalPackage HPSCSI_HBAPhysicalPackage represents the overall physical package for the SCSI HBA and iSCSI HBA as a whole. There is one instance per HBA.
HP Confidential Table 17-8 Class: HPSCSI_DiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Disk location (for example, SCSIBUS:1 SCSIID:0) CIM_ManagedSystemElement Name Drive index CIM_PhysicalElement CreationClassName HPSCSI_DiskPhysicalPackage Manufacturer Drive vendor Model Drive model string OtherIdentifyingInfo HBA index value supplied by underlying API PartNumber N/A—Not available in this implementation RemovalConditions
HP Confidential Table 17-9 Class: HPSCSI_StorageEnclosure (CIM_Chassis) Property name Property implementation CreationClassName HPSCSI_StorageEnclosure Manufacturer Enclosure vendor string Model Enclosure model string (for example, PROLIANT 4L6I) PartNumber N/A—Not available in this implementation SerialNumber Enclosure Serial Number Tag Opaque key Version N/A—Not available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) CIM_PhysicalFrame CIM_Chassis HP_Sto
HP Confidential Table 17-10 Class: HPSCSI_StorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation OperationalStatus Operational status for enclosure and associated power supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile.
HP Confidential Table 17-11 Class: HPSCSI_HBAPortController (CIM_PortController) Property name Property implementation ElementName Controller name and location (for example, SCSI Controller Port 1 in Slot 4) for SCSI controller Controller name (for example, iSCSI Initiator) for iSCSI Initiator CIM_ManagedSystemElement Name Controller model name OperationalStatus Operational status of the controller StatusDescriptions Description about the Operational Status CIM_LogicalElement CIM_EnabledLogicalEle
HP Confidential Table 17-12 Class: HPSCSI_DAPort (CIM_DAPort) Property name Property implementation ElementName Controller name and location (for example, SCSI Controller Port 1 in Slot 4) CIM_ManagedSystemElement OperationalStatus[0] Port status 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not applicable) RequestedState 12 (Not applicable) CIM_LogicalDevice CreationClassName HPSCSI_DAPort DeviceID Opaque key Syst
HP Confidential Table 17-13 Class: HPSCSI_HBASPIPort (CIM_SPIPort) Property name Property implementation OperationalStatus[0] Port status 0 (Unknown) 2 (OK) 6 (Error) StatusDescriptions Description about the Operational Status CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not applicable) RequestedState 12 (Not applicable) CIM_LogicalDevice CreationClassName HPSCSI_HBASPIPort DeviceID Opaque key SystemCreationClassName HPSCSI_HBAComputerSystem
HP Confidential Table 17-14 Class: HPSCSI_HBAFirmwareIdentity (CIM_SoftwareIdentity) Property name Property implementation Name SCSI HBA Firmware CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions[0] SCSI HBA Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer HBA vendor string IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ: VersionString Controller firmware version string IsEntity FALSE 17-3-14 HPSCSI_EnclosureFirmw
HP Confidential 17-3-15 HPSCSI_MediaAccessStatData HPSCSI_MediaAccessStatData represents the monitoring and performance data counters on HP disk drives.
HP Confidential Table 17-17 Class: HPSCSI_DriveCage (CIM_PhysicalPackage) Property name Property implementation CIM_PhysicalElement CreationClassName HPSCSI_DriveCage Manufacturer Vendor string Model Drive Cage Model string PartNumber N/A—Not available in this implementation SerialNumber Serial number if known Tag Opaque key Version N/A—Not available in this implementation CIM_PhysicalPackage RemovalConditions 0 Unknown 2 (Not Applicable) 3 (Removable when off) 4 (Removable when o
HP Confidential Table 17-18 Class: HPSCSI_HBASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint CreationClassName HPSCSI_HBASCSIProtocolEndpoint SystemCreationClassName HPSCSI_HBAComputerSystem SystemName HBA index CIM_ProtocolEndpoint ProtocolIFType 0 (Unknown) CIM_SCSIProtocolEndpoint ConnectionType 1 (Other) OtherConnectionType PCI Role 4 (Both Initiator and Target)
HP Confidential Table 17-19 Class: HPSCSI_DASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation ProtocolIFType 0 (Unknown) CIM_SCSIProtocolEndpoint ConnectionType 3 (Parallel SCSI) Role 2 (Initiator) 17-3-19 HPSCSI_HBASCSIProtocolController HPSCSI_HBASCSIProtocolController represents a view of SCSI resources on the SCSI HBA. This is required to model the presentation of SCSI LUNs to the host system.
HP Confidential 17-3-20 HPSCSI_HBAGroupCollection HPSCSI_HBAGroupCollection represents a collection of SCSI HBA controllers that have been grouped together to report a consolidated status.
HP Confidential Table 17-22 Class: HPSCSI_StorageEnclosureLocation (HP_Location) Property name Property implementation HP_Location External for external enclosures Internal for drive cages located within the host ElementLocationTag chassis ElementLocationTagDesc 17-3-22 19 (Box) HPSCSI_DriveCageLocation HPSCSI_DriveCageLocation represents a location string for the drive cage.
HP Confidential Table 17-24 Class: HPSCSI_HBALocation (HP_Location) Property name Property implementation CIM_ ManagedElement ElementName Controller name and location (for example, SCSI Controller Port 1 in Slot 4) for SCSI controller Controller name (for example, iSCSI Initiator) for iSCSI Initiator Caption Controller name and location For example, SCSI Controller Port 1 in Slot 4 for SCSI controller ElementName : Initiator InstanceID for iSCSI Initiator Description Controller name and location For
HP Confidential Table 17-25 Class: HPSCSI_DiskDriveLocation (HP_Location) Property name Property implementation CIM_ ManagedElement ElementName Disk name (for example, SCSIBUS:1 SCSIID:0) Caption Disk name For example, SCSIBUS:1 SCSIID:0 Description Disk name For example, SCSIBUS:1 SCSIID:0 CIM_Location Name Key PhysicalPosition Key HP_Location ElementLocationTag Drive SCSI ID ElementLocationTagDesc 0 (Hood Tag) 17-3-25 HPSCSI_HBAProduct HPSCSI_HBAProduct represents the top-level marketin
HP Confidential Table 17-27 Class: HPSCSI_HBAComputerSystemStorageEnclosureProcessor (CIM_SystemComponent) Property name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_StorageEnclosureProcessor HPSCSI_HBAComputerSystemSCSIProtocolController (Association) 17-3-27 Table 17-28 Class: HPSCSI_HBAComputerSystemSCSIProtocolController (CIM_SystemDevice) Property name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_HBASCSIProtoco
HP Confidential Table 17-31 Class: HPSCSI_HBAComputerSystemStorageVolume (CIM_SystemDevice) Property name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_StorageVolume HPSCSI_HBAComputerSystemStorageExtent (Association) 17-3-31 Table 17-32 Class: HPSCSI_HBAComputerSystemStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent HPSCSI_HBAComputerSystem PartComponent HPSCSI_StorageExtent 17-3-32 HPSCSI_HBAComputerSystemSPIPort (As
HP Confidential HPSCSI_StorageEnclosureStorageEnclosureProcessor (Association) 17-3-35 Table 17-36 Class: HPSCSI_StorageEnclosureStorageEnclosureProcessor (CIM_systemPackaging) Property name Property implementation Antecedent HPSCSI_StorageEnclosure Dependent HPSCSI_StorageEnclosureProcessor 17-3-36 HPSCSI_HBAProductPhysicalComponent (Association) Table 17-37 Class: HPSCSI_HBAProductPhysicalComponent (CIM_ProductPhysicalPackage) Property name Property implementation GroupComponent HPSCSI_HBAPro
HP Confidential Table 17-40 Class: HPSCSI_DriveCageDiskDrive (CIM_Container) Property name Property implementation GroupComponent HPSCSI_DriveCage PartComponent HPSCSI_DiskPhysicalPackage HPSCSI_HBAComputerSystemHBAFirmwareIdentity (Association) 17-3-40 Table 17-41 Class: HPSCSI_HBAComputerSystemHBAFirmwareIdentity (CIM_InstalledSoftwareIdentity) Property name Property implementation Antecedent HPSCSI_HBAFirmwareIdentity Dependent HPSCSI_HBAComputerSystem ElementSoftwareStatus ElementSoftwa
HP Confidential Table 17-43 Class: HPSCSI_StorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) HPSCSI_DiskDriveDiskDriveFirmwareIdentity (Association) 17-3-43 Table 17-44 Class: HPSCSI_DiskDriveDiskDriveFirmwareIdentity (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HPSCSI_DiskDriveFirmwareIdentity Dependen
HP Confidential Table 17-47 Class: HPSCSI_StorageExtentStorageVolume (CIM_BasedOn) Property name Property implementation SystemElement HPSCSI_StorageExtent SameElement HPSCSI_StorageVolume 17-3-47 HPSCSI_DAPortSCSIProtocolEndpoint (Association) Table 17-48 Class: HPSCSI_DAPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent HPSCSI_DAPort Dependent HPSCSI_DASCSIProtocolEndpoint 17-3-48 HPSCSI_HBASCSIProtocolEndpointSPIPort (Association) Tabl
HP Confidential Table 17-51 Class: HPSCSI_HBAGroupCollectionHBAComputerSystem (CIM_MemberOfCollection) Property name Property implementation Member HPSCSI_ HBAComputerSystem Collection HPSCSI_HBAGroupCollection 17-3-51 HPSCSI_HBASystemPackaging (Association) Table 17-52 Class: HPSCSI_HBASystemPackaging (CIM_ComputerSystemPackage) Property name Property implementation Antecedent HPSCSI_HBAPhysicalPackage Dependent HPSCSI_HBAComputerSystem HPSCSI_HBAPhysicalPackagePortController (Association) 1
HP Confidential Table 17-55 Class: HPSCSI_HBAPhysicalPackageLocation (CIM_PhysicalElementLocation) Property name Property implementation PhysicalLocation HPSCSI_HBALocation HPSCSI_StorageEnclosureEnclosureLocation (Association) 17-3-55 Table 17-56 Class: HPSCSI_StorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HPSCSI_StorageEnclosure PhysicalLocation HPSCSI_StorageEnclosureLocation 17-3-56 HPSCSI_DriveCageDriveCageLocation (Association
HP Confidential Table 17-59 Class: HPSCSI_SCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement) Property name Property implementation AvailableSAP HPSCSI_DASCSIProtocolEndpoint ManagedElement HPSCSI_HBASCSIProtocolController 17-3-59 HPSCSI_HBAPortControllerHBASPIPort (Association) Table 17-60 Class: HPSCSI_HBAPortControllerHBASPIPort (CIM_ControlledBy) Property name Property implementation Antecedent HPSCSI_HBAPortController Dependent HPSCSI_HBASPIPort HPSCSI_HBAComputerSyst
HP Confidential Table 17-62 HPSCSI_DeviceIndication: Physical Drive status set to OK Property name Property implementation AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 4 ProviderName HP SCSI RecommendedActions No action required SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_Alert
HP Confidential Table 17-62 HPSCSI_DeviceIndication: Physical Drive status set to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 17-63 HPSCSI_DeviceIndication: Physical Drive status set to ERROR Property name Property implementation CIM_AlertIndication Description A SCSI physical drive has a status of Error AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 5 ProviderName HP SCSI RecommendedActions Check for failed or removed physical drives.
HP Confidential Table 17-63 HPSCSI_DeviceIndication: Physical Drive status set to ERROR Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
HP Confidential Table 17-64 HPSCSI_DeviceIndication: Physical Drive status is set to Predictive Failure Property name Property implementation PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description SCSI physical drive status is now set to predictive failure.
HP Confidential Table 17-64 HPSCSI_DeviceIndication: Physical Drive status is set to Predictive Failure Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the prope
HP Confidential Table 17-65 HPSCSI_DeviceIndication: Physical Drive status OFFLINE Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 6 (Critical) IndicationTime Time of indication CIM_AlertIndication Description The physical drive is offline and can no longer return data. No further status is available.
HP Confidential Table 17-65 HPSCSI_DeviceIndication: Physical Drive status OFFLINE Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for al
HP Confidential Table 17-66 HPSCSI_DeviceIndication: Physical Drive status - Missing was OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A SCSI physical drive with a status of OK that was located in the system has been removed AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance AlertingElementFormat 2 (CIMObjec
HP Confidential Table 17-66 HPSCSI_DeviceIndication: Physical Drive status - Missing was OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (Syste
HP Confidential Table 17-67 HPSCSI_DeviceIndication: Physical Drive status - Missing was FAILED Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A SCSI physical drive with a status of Error that was located in the system has been removed AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance AlertingElementFormat 2 (CIM
HP Confidential Table 17-67 HPSCSI_DeviceIndication: Physical Drive status - Missing was FAILED Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (S
HP Confidential Table 17-68 HPSCSI_DeviceIndication: Physical Drive status - Missing was Predictive Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A SCSI physical drive with a status of Predictive Failure that was located in the system has been removed AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance Aler
HP Confidential Table 17-68 HPSCSI_DeviceIndication: Physical Drive status - Missing was Predictive Failure Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSy
HP Confidential Table 17-69 HPSCSI_DeviceIndication: Physical Drive status—Missing was OFFLINE Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Information) IndicationTime Time of indication CIM_AlertIndication Description A SCSI physical drive that was located in the system and had a status of offline has been removed AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance AlertingElementFormat 2
HP Confidential Table 17-69 HPSCSI_DeviceIndication: Physical Drive status—Missing was OFFLINE Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (Sy
HP Confidential Table 17-70 HPSCSI_DeviceIndication: Controller status changed to Unknown Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 0 (unknown) IndicationTime Time of indication CIM_AlertIndication Description A SCSI device status has changed to Unknown AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID
HP Confidential Table 17-70 HPSCSI_DeviceIndication: Controller status changed to Unknown Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system genera
HP Confidential Table 17-71 HPSCSI_DeviceIndication: Controller status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description This SCSI HBA status has changed from non-OK to OK AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 2 ProviderN
HP Confidential Table 17-71 HPSCSI_DeviceIndication: Controller status OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other s
HP Confidential Table 17-72 HPSCSI_DeviceIndication: Controller status ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 6 (Critical) IndicationTime Time of indication CIM_AlertIndication Description A SCSI HBA status has changed to Error AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 3 ProviderName
HP Confidential Table 17-72 HPSCSI_DeviceIndication: Controller status ERROR Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all othe
HP Confidential Table 17-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Supply status has changed to non-redundant AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 (CIMObjectPath) AlertType
HP Confidential Table 17-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, ..
HP Confidential 17-4-13 Power Supply Status OK Table 17-74 HPSCSI_DeviceIndication: Power Supply status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Supply has changed to Fully Redundant AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 (CIMObjectP
HP Confidential Table 17-74 HPSCSI_DeviceIndication: Power Supply status OK Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, ..
HP Confidential Table 17-74 HPSCSI_DeviceIndication: Power Supply status OK Property name Property implementation DeviceModel Enclosure Model string 17-4-14 Power Supply Status DEGRADED Table 17-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Supply statu
HP Confidential Table 17-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED Property name Property implementation OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, ..
HP Confidential Table 17-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED Property name Property implementation HWFirmwareVersion Enclosure firmware version string HWLogicalLocation Enclosure Location string HWManufacturer Enclosure Manufacturer string HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel 17-4-15 Enclosure Model string Temperature sensor Status change OK Table 17-76 HPSCSI_DeviceIndication: Temperature sensor status change OK Property name Property i
HP Confidential Table 17-76 HPSCSI_DeviceIndication: Temperature sensor status change OK Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 17-76 HPSCSI_DeviceIndication: Temperature sensor status change OK Property name Property implementation SolutionProductModel Conditional property containing the Solution Name string when running in a aggregate product environment in the format v..
HP Confidential Table 17-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition Property name Property implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Temperature sensor status Warning Condition EventCategory 24 (Primary Storage Cooling) ProbableCause 51 (Temperature unacceptable) ProbableCauseDescription Temperature Statu
HP Confidential Table 17-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment SolutionProdu
HP Confidential Table 17-78 HPSCSI_DeviceIndication: Temperature sensor status change—Critical Property name Property implementation AlertType 5 (Device Alert) EventID 309 ProviderName HP SCSI RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
HP Confidential Table 17-78 HPSCSI_DeviceIndication: Temperature sensor status change—Critical Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 17-79 HPSCSI_DeviceIndication: Fan status change—OK Property name Property implementation Description The storage enclosure fan subsystem is operating properly AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 304 ProviderName HP SCSI RecommendedActions No action is necessary SystemName Name of the computer system generating the indication SystemCreationCla
HP Confidential Table 17-79 HPSCSI_DeviceIndication: Fan status change—OK Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Confidential Table 17-80 HPSCSI_DeviceIndication: Fan status change—Degraded Property name Property implementation PerceivedSeverity 4 (Minor) IndicationTime Time of indication CIM_AlertIndication Description A fan has failed, but there are enough fans in the fan subsystem to keep the enclosure cool AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor class instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 305 ProviderName HP SCSI Re
HP Confidential Table 17-80 HPSCSI_DeviceIndication: Fan status change—Degraded Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all o
HP Confidential Table 17-81 HPSCSI_DeviceIndication: Fan status change - ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A fan has failed and there are not enough fans in the fan subsystem to keep the enclosure cool.
HP Confidential Table 17-81 HPSCSI_DeviceIndication: Fan status change - ERROR Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, ..
HP Confidential Table 17-81 HPSCSI_DeviceIndication: Fan status change - ERROR Property name Property implementation DeviceModel Enclosure Model string
HP Confidential 18 FC HBA 18-1 Overview This provider implements the HP FC HBA Profile, which describes the behavior of Fibre Channel host adapters supporting the SCSI (FCP) command set. A Fibre Channel adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports. A single system can contain one or more HBAs. The following table details the profiles implemented and files installed by this provider.
HP Confidential Figure 18-1 Instance diagram for a single HBA with two controllers with one port on each controller 18-2-1 Get statistics for each Fibre Channel port 1. For each instance of HPFCHBA_ComputerSystem, find the corresponding instance of the associations HPFCHBA_ComputerSystemFCPort. 2. For each association of HPFCHBA_ComputerSystemFCPort, get the corresponding instance of HPFCHBA_FCPort.
HP Confidential 3. For each instance of HPFCHBA_FCPort, get the corresponding instance of the association HPFCHBA_FCPortFCPortStatistics. 4. For each association instance of HPFCHBA_FCPortFCPortStatistics get the corresponding instance of HPFCHBA_FcPortStatistics. Figure 18-2 Get the statistics for each port 18-2-2 Discovering HBA topology and attributes 5. Get the instance of HPFCHBA_ComputerSystem on a managed system. 6.
HP Confidential 13. For each instance of association HPFCHBA_PortControllerFirmwareIdentityFW, get the corresponding instance of HPFCHBA_FirmwareIdentityFW. The VersionString property contains the firmware version. Other properties of interest are Description, ElementName, and Manufacturer. 14. For each instance of HPFCHBA_PortController, get the corresponding association HPFCHBA_PortControllerFirmwareIdentityBIOS. 15.
HP Confidential Figure 18-3 Discover HBA topology and attributes 18-3 Class implementations 18-3-1 HPFCHBA_ComputerSystem HPFCHBA_ComputerSystem is used to identify classes that represent all Fibre Channel ports.
HP Confidential Table 18-2 Class: HPFCHBA_ComputerSystem Property name Property implementation CIM_ManagedElement Caption Fibre Channel System ElementName Fibre Channel System CIM_ManagedSystemElement Name GUID OperationalStatus 0 (Unknown) Unknown StatusDescriptions 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) Other OK Degraded Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable)
HP Confidential Table 18-3 Class: HPFCHBA_FCPort Property name Property implementation CIM_ManagedElement ElementName Fibre Channel Port CIM_ManagedSystemElement OperationalStatus[0] StatusDescriptions[0] 0 (Unknown) Unknown 2 (OK-Online) 6 (Error) 10 (Stopped) 11 (In Service) OK-Online Offline Bypassed Diagnostics Link down Error Loopback CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not
HP Confidential Table 18-3 Class: HPFCHBA_FCPort Property name Property implementation OtherPortType other Not present Fabric Public Loop FL Port Fabric Port Fabric expansion port Generic Fabric Port Private Loop Point to Point PortType 1 (Other) Speed One of (in Bits per Second): UsageRestriction 0 1000000000 2000000000 10000000000 4 (not restricted) CIM_NetworkPort LinkTechnology 4 (FC) PermanentAddress PortWWN PortNumber Port number SupportedMaximumTransmiss
HP Confidential Table 18-3 Class: HPFCHBA_FCPort Property name Property implementation ActiveFC4Types[] Array of port active FC4 type bits (Possible values in array (decimal) ) Unknown -- 0 Other -- 1 ISO/IEC 8802 - 2 LLC -- 4 IP over FC -- 5 SCSI - FCP -- 8 SCSI - GPP -- 9 IPI - 3 Master -- 17 IPI - 3 Slave -- 18 IPI - 3 Peer -- 19 CP IPI - 3 Master -- 21 CP IPI - 3 Slave -- 22 CP IPI - 3 Peer -- 23 SBCCS Channel -- 25 SBCCS Control Unit -- 26 FC-SB-2 Channel -- 27 FC-SB-2 Control Unit -- 28 Fibre Chan
HP Confidential Table 18-3 Class: HPFCHBA_FCPort Property name Property implementation SupportedFC4Types[] Array of port supported FC4 type bits (Possible values in array (decimal) ) Unknown -- 0 Other -- 1 ISO/IEC 8802 - 2 LLC -- 4 IP over FC -- 5 SCSI - FCP -- 8 SCSI - GPP -- 9 IPI - 3 Master -- 17 IPI - 3 Slave -- 18 IPI - 3 Peer -- 19 CP IPI - 3 Master -- 21 CP IPI - 3 Slave -- 22 CP IPI - 3 Peer -- 23 SBCCS Channel -- 25 SBCCS Control Unit -- 26 FC-SB-2 Channel -- 27 FC-SB-2 Control Unit -- 28 Fibr
HP Confidential Table 18-4 Class: HPFCHBA_PortController Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPFCHBA_PortController DeviceID NodeWWN:SerialNumber SystemCreationClassName HPFCHBA_ComputerSystem SystemName HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:PORTWWN: portwwn, where nodewwn is the node‘s WWN and portwwn is the por
HP Confidential Table 18-5 Class: HPFCHBA_FCPortStatistics Property name Property implementation PacketsTransmitted 0 (required property set to zero because this information is not collected by the HBA) PacketsReceived 0 (required property set to zero because this information is not collected by the HBA) CIM_FCPortStatistics 18-3-5 CRCErrors HBAAPI_PORTSTATISTICS.InvalidCRCCount DumpedFrames HBAAPI_PORTSTATISTICS.DumpedFrames ErrorFrames HBAAPI_PORTSTATISTICS.
HP Confidential Table 18-6 Class: HPFCHBA_LogicalPortGroup Property name Property implementation CIM_LogicalPortGroup 18-3-6 Name PortWWN NameFormat WWN HPFCHBA_PhysicalPackage HPFCHBA_PhysicalPackage class represents the physical elements of the associated Fibre Channel port controller.
HP Confidential HPFCHBA_Product is used to aggregate physical element of the FC HBA. In the following table, HBAAPI_ADAPTERATTRIBUTES prefix refers to the HBA API HBA_ADAPTERATTRIBUTES structure. This information comes directly from the HBA and is not altered.
HP Confidential Table 18-9 Class: HPFCHBA_SoftwareIdentityDrv 18-3-9 Property name Property implementation IsEntity False HPFCHBA_FirmwareIdentityFW HPFCHBA_FirmwareIdentityFW represents adapter firmware associated with the Fibre Channel port controller. Table 18-10 Class: HPFCHBA_FirmwareIdentityFW Property name Property implementation CIM_ManagedElement Caption FC HBA Firmware Description Description FC HBA Firmware details for Model Name, where model name is the model name of the HBA.
HP Confidential Table 18-11 Class: HPFCHBA_FirmwareIdentityBIOS (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedElement Caption FC HBA Option ROM Description FC HBA Option ROM detail for Model Name, where model name is the model name of the HBA.
HP Confidential Table 18-12 Class: HPFCHBA_SCSIProtocolController Property name Property implementation CIM_ManagedSystemElement OperationalStatus[0] 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HPFCHBA_SCSIProtocolController DeviceID PortWWN SystemName HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:P
HP Confidential Table 18-13 Class: HPFCHBA_SCSIProtocolEndpoint Property name Property implementation EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint CreationClassName HPFCHBA_SCSIProtocolEndpoint SystemName HPQ:GUID: 85408DBD-6A39-41CD-9E5A357AEA130BBF:NODEWWN:nodewwn:PORTWWN: portwwn, where nodewwn is the node‘s WWN and portwwn is the port‘s WWN SystemCreationClassName HPFCHBA_ComputerSystem CIM_ProtocolEndpoint ProtocolIFType 57 (HIPPI Interface) CIM_SCS
HP Confidential Table 18-14 Class: HPFCHBA_GroupSystemSpecificCollection Property name Property implementation GroupOperationalStatus[0] 0 (Unknown) Unknown GroupStatusDescriptions[0] 18-3-14 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) Other OK Degraded Error HPFCHBA_ComputerSystemFCPort HPFCHBA_ComputerSystemFCPort is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_FCPort.
HP Confidential Table 18-16 Class: HPFCHBA_ComputerSystemPortController Property name Property implementation PartComponent ref:HPFCHBA_PortController 18-3-16 HPFCHBA_ComputerSystemSCSIProtocolController HPFCHBA_ComputerSystemSCSIProtocolController is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_SCSIProtocolController.
HP Confidential Table 18-19 Class: HPFCHBA_ComputerSystemSoftwareIdentityDrv Property name Property implementation CIM_InstalledSoftwareIdentity HPFCHBA_ComputerSystemSoftwareIdentityDrv InstalledSoftware ref:HPFCHBA_SoftwareIdentityDrv System ref:HPFCHBA_ComputerSystem 18-3-19 HPFCHBA_SystemServiceAccessPoint HPFCHBA_SystemServiceAccessPoint is used to represent an association between HPFCHBA_ComputerSystem and HPFCHBA_SCSIProtocolEndpoint.
HP Confidential HPFCHBA_FCPortLogicalPortGroup is used to represent an association between HPFCHBA_FCPort and HPFCHBA_LogicalPortGroup.
HP Confidential 18-3-24 HPFCHBA_PortControllerFCPort HPFCHBA_PortControllerFCPort is used to represent an association between HPFCHBA_PortController and HPFCHBA_FCPort.
HP Confidential Table 18-27 Class: HPFCHBA_SoftwareIdentityDrvPortController Property name Property implementation Antecedent ref:HPFCHBA_SoftwareIdentityDrv Dependent ref:HPFCHBA_PortController 18-3-27 HPFCHBA_PortControllerFirmwareIdentityFW HPFCHBA_PortControllerFirmwareIdentityFW is used to represent an association between HPFCHBA_PortController and HPFCHBA_FirmwareIdentityFW.
HP Confidential Table 18-30 Class: HPFCHBA_ProductPhysicalComponent Property name Property implementation CIM_Component CIM_ProductPhysicalComponent HPFCHBA_ProductPhysicalComponent GroupComponent ref:HPFCHBA_Product PartComponent ref:HPFCHBA_PhysicalPackage 18-3-30 HPFCHBA_SystemPackaging HPFCHBA_SystemPackaging is used to represent an association between HPFCHBA_PhysicalPackage and HPFCHBA_ComputerSystem.
HP Confidential HPFCHBA_GroupHostedCollection is used to represent an association between CIM_ComputerSystem and HPFCHBA_GroupSystemSpecificCollection.
HP Confidential Table 18-35 Class: HPFCHBA_Location Property name Property implementation HP_Location ElementLocationTag slot number ElementLocationTagDesc 1 (slot) 18-3-35 HPFCHBA_PhysicalElementLocation HPFCHBA_PhysicalElementLocation is used to represent an association between the HPFCHBA_PhysicalPackage and HPFCHBA_Location.
HP Confidential Table 18-37 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to OK Property name Property implementation EventID 2 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Fibre Channel RecommendedActions No action is recommended SystemName HP_ComputerSystem.SystemName SystemCreationClassName HP_ComputerSystem.
HP Confidential Table 18-37 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to OK 18-4-2 Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment BladeBay HP_BladeCSLocation.LocationInformation[0] BladeName HP_ComputerSystem.Name EnclosureName HP_BladeEnclosureCS.
HP Confidential Table 18-38 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to Link Down Property name Property implementation EventID 6 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Fibre Channel RecommendedActions 1 2 3 SystemName HP_ComputerSystem.SystemName SystemCreationClassName HP_ComputerSystem.
HP Confidential Table 18-38 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to Link Down 18-4-3 Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment BladeBay HP_BladeCSLocation.LocationInformation[0] BladeName HP_ComputerSystem.
HP Confidential Table 18-39 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status Unknown Property name Property implementation AlertingManagedElement WBEM Path of HPFCHBA_DeviceIndication AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Fibre Channel RecommendedActions Check the fibre channel HBA driver and the WMI providers to ensure that the correct versions of this
HP Confidential Table 18-39 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status Unknown 18-4-4 Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment BladeBay HP_BladeCSLoc
HP Confidential Table 18-40 Class: HPFCHBA_DeviceIndication: Fibre Channel Port in offline state Property name Property implementation Description A fibre channel port has changed to a state of Offline.
HP Confidential Table 18-40 Class: HPFCHBA_DeviceIndication: Fibre Channel Port in offline state 18-4-5 Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment BladeBay HP_BladeCSL
HP Confidential Table 18-41 Class: HPFCHBA_DeviceIndication: Fibre Channel Port in bypass state Property name Property implementation Description A fibre channel port has changed to a state of bypassed.
HP Confidential Table 18-41 Class: HPFCHBA_DeviceIndication: Fibre Channel Port in bypass state 18-4-6 Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system
HP Confidential Table 18-42 Class: HPFCHBA_DeviceIndication: Fibre Channel Port in diagnostic state Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description A fibre channel HBA port is operating in a diagnostic state.
HP Confidential Table 18-42 Class: HPFCHBA_DeviceIndication: Fibre Channel Port in diagnostic state 18-4-7 Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect e
HP Confidential Table 18-43 Class: HPFCHBA_DeviceIndication: Fibre Channel Port failed Property name Property implementation PerceivedSeverity 6 (Critical) IndicationTime Time of indication CIM_AlertIndication Description A fibre channel port has changed to a failed status.
HP Confidential Table 18-43 Class: HPFCHBA_DeviceIndication: Fibre Channel Port failed 18-4-8 Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment S
HP Confidential Table 18-44 Class: HPFCHBA_DeviceIndication: Fibre Channel in loopback state Property name Property implementation PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A fibre channel port has changed to a loop back state.
HP Confidential Table 18-44 Class: HPFCHBA_DeviceIndication: Fibre Channel in loopback state Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment Syst
HP Confidential 19 System software 19-1 Overview This provider implements the DMTF Software Inventory profile to support inventory of installed HP software on ProLiant systems. The following profiles are implemented, and files are installed by this provider. Table 19-1 Overview 19-2 Implemented Profiles DMTF Software Inventory Profile 1.0 Provider Installation Files HPWmiSys.DLL Use cases For use cases, see the DMTF Software Inventory Profile.
HP Confidential Table 19-2 Class: CIM_SoftwareIdentity Property name Property implementation ElementName Contains the corresponding comma separated values of IdentityInfoValue array for the corresponding CIM:SoftwareFamily type described in the IdentityInfoType array. Format: ,,…,, where each is the intended value in IdentityInfoValue array For example, HPQ: for each CIM:SoftwareFamily IdentityInfoType.
HP Confidential Table 19-2 Class: CIM_SoftwareIdentity Property name Property implementation VersionString Version of the software identity as reported by its underlying instrumentation. If this version can be represented in the following format: MM.mm.rr.bb, where integers MM is MajorVersion, mm is MinorVersion, rr is RevisionNumber, and bb is BuildNumber, then VersionString is set to ―‖, and MajorVersion, MinorVersion, RevisionNumber and BuildNumber properties represent the software version instead.
HP Confidential 19-4 Supported indications There are no indications produced for Software Inventory.
HP Confidential 20 Profile registration 20-1 Overview The following profiles are implemented and files are installed by this provider. Table 20-1 Overview 20-2 Implemented Profiles HP Profile Registration Profile (P00100) Provider Installation Files HPWmiProfile.dll HPWmiProfile.mof Use cases For use cases, see the HP Profile Registration profile (P00100). 20-3 Class implementations The following classes describe registration of HP supported profiles.
HP Confidential Table 20-2 Class: HP_RegisteredProfile and HP_RegisteredSubProfile Property name Property implementation OtherRegisteredOrganization NULL for DMTF profiles None for SNIA SMI-S storage profiles ―HP WBEM TC ― for HP profiles RegisteredName See Tables 3-3, 3-4, 3-5 and 3-6 RegisteredOrganization 2 (DMTF) for DMTF profiles 11 (SNIA) for SNIA SMI-S storage profiles 1 (Other) for for HP profiles RegisteredVersion See Tables 3-3, 3-4, 3-5 and 3-6 Table 20-3 Property Values of
HP Confidential Table 20-4 Property Values of HP_RegisteredProfile for SNIA Profiles RegisteredName Registered Version InstanceID Caption/Description/ ElementName Array 1.4.4 SNIA:Array:144 SNIA Array Profile DDL 1.3.0 SNIA:DDL:130 SNIA Disk Drive Lite Profile Disk Sparing 1.3.0 SNIA:Disk_Sparing:130 SNIA Disk Sparing Profile Extent Mapping 1.3.0 SNIA:ExtentMapping:130 SNIA Extent Mapping Profile FC HBA 1.2.0 SNIA:FCHBA:120 SNIA FC HBA Profile Host Discoverted Reources 1.2.
HP Confidential Table 20-6 Property Values of HP_RegisteredProfile for ―HP WBEM TC‖ Profiles 20-3-2 RegisteredName Registered Version InstanceID Caption/Description/ ElementName HP CPU Consolidated Status 1.0.0 HP:CPU Consolidated Status HP CPU Consolidated Status Profile HP CPU Physical Asset 1.0.0 HP:CPU Physical Asset HP CPU Physical Asset Profile HP Ethernet Teaming 1.0.1 HP:EthernetTeaming HP Ethernet Teaming profile HP Fan 1.3.0 HP:Fan HP Fan Profile HP Fan Physical Asset 1.1.
HP Confidential Table 20-7 Class: HP_ExtendsProfile Property name Property implementation CIM_Dependency HP_ExtendsProfile 20-3-3 Antecedent ref: CIM_RegisteredProfile (extended) Dependent ref: HP_RegisteredProfile (extends) HP_ReferencedProfile HP_ReferencedProfile extends the class CIM_ ReferencedProfile and associates an HP profile that references another profile when both are registered in the root\Interop namespace. The following properties are implemented.
HP Confidential 20-4 Supported indications There are no indications specific to the profile registration implementation.
HP Confidential 21 Standalone tape drive 21-1 Overview The HP Standalone Tape Drive data sheet describes implementation of tape drives directly attached to a Host system. The following profiles are implemented, and files are installed by this provider. Table 21-1 Overview Implemented Profiles Provider Installation Files 21-2 HP Standalone Tape Drive Profile HPWMITape.
HP Confidential Table 21-2 Class: HPWMITape_TapeDrive Property name Property implementation CIM_ManagedSystemElement OperationalStatus [0] 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) 10 (Stopped / Offline) StatusDescriptions[0] Not Implemented Name Name for the device.
HP Confidential Table 21-3 Class: HPWMITape_TapeDriveStatData Property name Property implementation CIM_ManagedElement CIM_StatisticalData InstanceID Uniquely identifies an instance of HPWMITape_TapeDriveStatData StatisticTime Not Implemented CIM_MediaAccessStatData ReadOperations Not implemented RecoveredReadOperations Not implemented RecoveredWriteOperations Not implemented UnrecoverableReadOperations Not implemented UnrecoverableWriteOperations Not implemented WriteOperations Not implem
HP Confidential Table 21-4 Class: HPWMITape_TapeDriveMediaLocation Property name Property implementation Tag Uniquely identifies an instance of HPWMITape_TapeDriveMediaLocation CIM_PhysicalPackage RemovalCondition Not implemented CIM_PackageLocation LocationCoordinates Unknown CIM_StorageMediaLocation LocationType 4 (Media Access Device) MediaCapacity The number of tapes that the tape drive can hold.
HP Confidential Table 21-5 Class: HPWMITape_PhysicalTape Property name Property implementation MaxMounts Not implemented MediaDescription Not implemented MediaType 2 (Tape Cartridge) MountCount The number of time this tape has been loaded PhysicalLabels[0] The tape barcode TimeOfLastMount Not implemented TotalMountTime Not implemented WriteProtectOn Not implemented CIM_PhysicalTape TapeLength Not implemented UnloadAnywhere Not implemented HPWMITape_PhysicalTape 21-3-5 HPWMITape_TapeD
HP Confidential Table 21-7 Class: HPWMITape_TapeDriveEnclosure Property name Property implementation CIM_ManagedSystemElement Name Not Implemented CIM_PhysicalElement CreationClassName HPWMITape_TapeDriveEnclosure Manufacturer HP Model Product ID of the drive For example, HP LTO IV PartNumber Not Implemented SerialNumber The tape drive serial number Tag Uniquely identifies an instance of HPWMITape_TapeDriveEnclosure Version Not Implemented CIM_PhysicalPackage RemovalConditions 0
HP Confidential Table 21-8 Class: HPWMITape_Product Property name Property implementation SKUNumber Not implemented Vendor HP Version Firmware Version WarrantyDuration Not implemented WarrantyStartDate Not implemented HPWMITape_Product 21-3-8 HPWMITape_SCSIProtocolEndpoint Table 21-9 Class: HPWMITape_SCSIProtocolEndpoint Property name Property implementation CIM_ManagedElement CIM_ManagedSystemElement Name Serial Number of the Tape Drive CIM_LogicalElement CIM_EnabledLogicalElement CIM_Serv
HP Confidential Table 21-10 Class: HPWMITape_TapeDriveFirmware Property name Property implementation CIM_ManagedElement CIM_ManagedSystemElement CIM_LogicalElement CIM_SoftwareIdentity BuildNumber Firmware version build number if available InstanceID Uniquely identifies an instance of HPWMITape_TapeDriveFirmware MajorVersion Firmware version minor number version if available MinorVersion Firmware version minor number version if available RevisionNumber Not implemented VersionString Firmware ve
HP Confidential Table 21-11 Class: HPWMITape_TapeDriveSPIPort Property name Property implementation StatusDescriptions More information for OperationalStatus result.
HP Confidential Table 21-12 Class: HPWMITape_TapeDriveSASPort Property name Property implementation CIM_ManagedSystemElement OperationalStatus[0] StatusDescriptions[0] 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) 10 (Stopped / Offline) Not Implemented CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault Not implemented EnabledState Not implemented RequestedState Not implemented CIM_LogicalDevice CreationClassName HPWMITape_TapeDriveSPIPort DeviceID Uniquely identif
HP Confidential Table 21-13 Association: HPWMITape_TapeSystemDevice Property name Property implementation PartComponent HPWMITape_TapeDrive 21-3-13 HPWMITape_LogicalPortSystemDevice (Association) Table 21-14 Association: HPWMITape_LogicalPortSystemDevice Property name Property implementation GroupComponent HP_WinComputerSystem PartComponent CIM_LogicalPort 21-3-14 HPWMITape_TapeDriveToCapabilities (Association) Table 21-15 Association: HPWMITape_TapeDriveToCapabilities Property name Property
HP Confidential Table 21-17 Association: HPWMITape_RealizeStorageMediaLocation Property name Property implementation Antecedent HPWMITape_TapeDriveMediaLocation Dependent HPWMITape_TapeDrive HPWMITape_TapeInTapeDriveMediaLocation (Association) 21-3-17 Table 21-18 Class: HPWMITape_TapeInTapeDriveMediaLocation Property name Property implementation Antecedent HPWMITape_TapeDriveMediaLocation Dependent HPWMITape_PhysicalTape Orientation 5 (Not Applicable) 21-3-18 HPWMITape_RealizePhysicalPacka
HP Confidential Table 21-21 Association: HPWMITape_TapeDriveToTapeDriveFirmware Property name Property implementation Antecedent HPWMITape_TapeDriveFirmware Dependent HPWMITape_TapeDrive 21-3-21 HPWMITape_InstalledDriveFirmware (Association) Table 21-22 Association: HPWMITape_TapeDriveToTapeDriveFirmware Property name Property implementation InstalledSoftware HPWMITape_TapeDriveFirmware System HP_WinComputerSystem HPWMITape_TapeDriveToProtocolEndpoint (Association) 21-3-22 Table 21-23 Assoc
HP Confidential Table 21-25 Association: HPWMITape_SCSIInitiatorTargetLUPath Property name Property implementation Initiator CIM_SCSIProtocolEndpoint LogicalUnit HPWMITape_TapeDrive Target HPWMITape_SCSIProtocolEndPoint HPWMITape_SCSIProtocolEndpointLogicalPort (Association) 21-3-25 Table 21-26 Association: HPWMITape_SCSIProtocolEndpointLogicalPort 21-4 Property name Property implementation Antecedent CIM_LogicalPort Dependent CIM_SCSIProtocolEndpoint Supported indications 21-4-1 Drive
HP Confidential Table 21-27 HP_TapeDriveDeviceIndication: Drive status changed to Unknown Property name Property implementation RecommendedActions See HPWMITapeEventMetaData.mof SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary See HPWMITapeEventMetaData.
HP Confidential Table 21-27 HP_TapeDriveDeviceIndication: Drive status changed to Unknown Property name Property implementation HWFirmwareVersion Enclosure F/W version string (It must match the HP_TapeDriveFirmware.VersionString) HWManufacturer Enclosure Manufacturer string HWSerialNumber Enclosure Serial Number (It must match the HP_StorageEnclosure.
HP Confidential Table 21-28 HP_TapeDriveDeviceIndication: Drive status changed to OK Property name Property implementation ProbableCause 1 (Other) ProbableCauseDescription Tape drive status changed to OK ProviderVersion Provider version generating the indication in the format, ...
HP Confidential 21-4-3 Drive status changed to Degraded Table 21-29 HP_TapeDriveDeviceIndication: Drive status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Degraded / Warning) IndicationTime Time of indication CIM_AlertIndication Description See HPWMITapeEventMetaData.
HP Confidential Table 21-29 HP_TapeDriveDeviceIndication: Drive status changed to Degraded Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, ..
HP Confidential Table 21-30 HP_TapeDriveDeviceIndication: Drive status changed to Failed Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 504 (Tape drive status changed to Failed) EventTime Time of the event or time of the indication if event time unknown ProviderName HP Tape RecommendedActions See HPWMITapeEventMetaData.
HP Confidential Table 21-30 HP_TapeDriveDeviceIndication: Drive status changed to Failed Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems HP_HardwareIndication HWFirmwareVersion Enclosure F/W version string (It must match the HP_TapeDriveFirmware.VersionString) HWManufacturer Enclosure Manufacturer string HWSerialNumber Enclosure Serial Number (It must match the HP_StorageEnclosure.
HP Confidential Table 21-31 HP_TapeDriveDeviceIndication: Drive status changed to Failed Property name Property implementation HP_AlertIndication Summary See HPWMITapeEventMetaData.mof EventCategory 7 (Secondary Storage Device) ProbableCause 1 (Other) ProbableCauseDescription A new tape drive was detected ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 21-31 HP_TapeDriveDeviceIndication: Drive status changed to Failed Property name Property implementation HP_TapeDriveDeviceIndication 21-4-6 Tape Drive status changed to Offline Table 21-32 HP_TapeDriveDeviceIndication: Tape Drive status changed to Offline Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 6 (Critical) IndicationTime Time of indication CIM_AlertIndication Description See HPWMITape
HP Confidential Table 21-32 HP_TapeDriveDeviceIndication: Tape Drive status changed to Offline Property name Property implementation OSType For Windows 2003 32-bit: 69 For Windows 2003 64-bit: 70 For Windows 2008 32-bit: 76 For Windows 2008 64-bit: 77 For Windows 2008 R2: 103 For Windows 2012: 113 OSVersion Operating system version of the computer system generating the indication in the format, ..
HP Confidential Table 21-33 HP_TapeDriveDeviceIndication: OK Tape Drive Now Missing Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description See HPWMITapeEventMetaData.
HP Confidential Table 21-33 HP_TapeDriveDeviceIndication: OK Tape Drive Now Missing Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for a
HP Confidential Table 21-34 HP_TapeDriveDeviceIndication: Failed Drive Now Missing Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Tape RecommendedActions See HPWMITapeEventMetaData.mof SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary See HPWMITapeEventMetaData.
HP Confidential Table 21-34 HP_TapeDriveDeviceIndication: Failed Drive Now Missing Property name Property implementation HWFirmwareVersion Enclosure F/W version string (It must match the HP_TapeDriveFirmware.VersionString) HWManufacturer Enclosure Manufacturer string HWSerialNumber Enclosure Serial Number (It must match the HP_StorageEnclosure.
HP Confidential Table 21-35 HP_TapeDriveDeviceIndication: Offline Drive Now Missing Property name Property implementation ProbableCause 73 (Element Missing) ProbableCauseDescription Missing tape drive that was Offline ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 21-36 HP_TapeDriveDeviceIndication: Degraded Drive Now Missing Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description See HPWMITapeEventMetaData.
HP Confidential Table 21-36 HP_TapeDriveDeviceIndication: Degraded Drive Now Missing Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating
HP Confidential Table 21-37 HP_TapeDriveDeviceIndication: Tape Drive Cleaning Required Property name Property implementation AlertType 5 (Device Alert) EventID 511 (Tape drive cleaning required) EventTime Time of the event or time of the indication if event time unknown ProviderName HP Tape RecommendedActions See HPWMITapeEventMetaData.
HP Confidential Table 21-37 HP_TapeDriveDeviceIndication: Tape Drive Cleaning Required Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems HP_HardwareIndication HWFirmwareVersion Enclosure F/W version string (It must match the HP_TapeDriveFirmware.VersionString) HWManufacturer Enclosure Manufacturer string HWSerialNumber Enclosure Serial Number (It must match the HP_StorageEnclosure.
HP Confidential Table 21-38 HP_TapeDriveDeviceIndication: Cleaning Tape Replacement Required Property name Property implementation HP_AlertIndication Summary See HPWMITapeEventMetaData.mof EventCategory 7 (Secondary Storage Device) ProbableCause 52 (Threshold Crossed) ProbableCauseDescription Cleaning tape needs to be replaced ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 21-38 HP_TapeDriveDeviceIndication: Cleaning Tape Replacement Required Property name Property implementation HP_TapeDriveDeviceIndication
HP Confidential 22 Host discovered resources (HDR) 22-1 Overview The HP Host Discovered Resources (HDR) data sheet describes the storage resources discovered on the host by the operating system. The following table details the profiles implemented and files installed by this provider. Table 22-1 Overview 22-2 Implemented Profiles HP Host Discovered Resources Profile Provider Installation Files HPWMIHDR.dll HPWMIHDR.mof HPWMIHDR_Registration.mof HPWMIHDR_Schema.
HP Confidential Table 22-2 Class: HPHDR_ComputerSytem Property name Property implementation Name Name of the host For example, aa.bb.abccorp.net CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_ManagedSystemElement Name Name of the host Foe example, aa.bb.abccorp.
HP Confidential Table 22-3 Class: HPHDR_SCSIProtocolEndPointInitiator 22-3-3 Property name Property implementation CreationClassName HPHDR_SCSIProtocolEndpointInitiator SystemCreationClassName HPHDR_ComputerSystem SystemName Name of the host For example, aa.bb.abccorp.net HPHDR_SCSIProtocolEndPointTarget HPHDR_SCSIProtocolEndPointTarget represents the Target information for the Storage Devices in the system. There is one instance per Target.
HP Confidential Table 22-4 Class: HPHDR_SCSIProtocolEndPointTarget 22-3-4 Property name Property implementation ProtocolIFType 3 (Target) HPHDR_LogicalDisk HPHDR_LogicalDisk represents the Logical Disks in the system. There is one instance per Logical Disk Drive.
HP Confidential Table 22-5 Class: HPHDR_LogicalDisk Property name Property implementation CreationClassName HPHDR_LogicalDisk SystemCreationClassName HPHDR_ComputerSystem SystemName Name of the host For example, aa.bb.abccorp.net CIM_StorageExtent BlockSize The block size in bytes 1 ConsumableBlocks Number of Free blocks. The total free space is calculated by multiplying the BlockSize by ConsumableBlocks.
HP Confidential Table 22-6 Class: HPHDR_RemoteServiceAccessPoint Property name Property implementation Name The SCSI VPD Page 85 information of the device. The information contains the http information of the Target Based Management server of the Storage Device For example, http://15.34.32.
HP Confidential Table 22-8 Class: HPHDR_ComputerSystemRemoteServiceAccessPoint 22-3-8 Property name Property implementation Antecedent HPHDR_ComputerSystem Dependent HPHDR_RemoteServiceAccessPoint HPHDR_ComputerSystemLogicalDisk (Association) Table 22-9 Class: HPHDR_ComputerSystemLogicalDisk Property name Property implementation GroupComponent HPHDR_ComputerSystem PartComponent HPHDR_LogicalDisk HPHDR_ComputerSystemSCSIProtocolEndpointInitiator (Association) 22-3-9 Table 22-10 Class: HPHDR_
HP Confidential 23 Host attached SATA 23-1 Overview The HP Host Attached SATA provider data sheet describes host attached SATA controllers and their attached disks. This implementation excludes externally attached SATA drives, which are part of external storage enclosures. The following profiles are implemented, and the following files are installed by this provider. Table 23-1 Overview Implemented Profiles P001300 HP Host Attached SATA Profile V1.0.0.
HP Confidential Table 23-2 Class: HP_SATAPortController(CIM_PortController) Property name Property implementation CIM_ManagedElement Caption Controller name Examples: Standard Dual Channel PCI IDE Controller Standard AHCI 1.
HP Confidential Table 23-2 Class: HP_SATAPortController(CIM_PortController) Property name Property implementation ControllerType The type or model of the port controller. Specific values Set to 1 ("Other"), the related property OtherControllerType contains a string description of the type of the controller. OtherControllerType OtherControllerType contains a string description of the type of the controller when ControllerType is set to 1.
HP Confidential Table 23-3 Class: HP_SATADiskDrive(CIM_DiskDrive) Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName HP_SATADiskDrive DeviceID Opaque Key SystemCreationClassName same value as property HP_WinComputerSystem.CreationClassName SystemName same value as property HP_WinComputerSystem.
HP Confidential Table 23-3 Class: HP_SATADiskDrive(CIM_DiskDrive) Property name Property implementation SectorsPerTrack The SectorsPerTrack property indicates the number of sectors in each track for this physical disk drive. Example: 63 TotalCylinders The total number of cylinders on the physical disk drive.
HP Confidential Table 23-4 Class: HP_SATAStorageExtent (CIM_StorageExtent) Property name Property implementation Description The Description property provides a textual description of the object. e.g: Installable File System ElementName A unique identifying name of the disk drive represented by this storageextent. e.g: \\.\PHYSICALDRIVE0 CIM_ManagedSystemElement Name The Name property defines the label by which the object is known e.
HP Confidential Table 23-4 Class: HP_SATAStorageExtent (CIM_StorageExtent) Property name Property implementation BootPartition The BootPartition property determines whether the partition is the active partition. The operating system uses the active partition when booting from a hard disk. Values: TRUE or FALSE. If TRUE, the partition is active. PrimaryPartition Boolean value indicating that the DiskPartition is labelled as the primary partition for a ComputerSystem.
HP Confidential Table 23-5 Class: HP_SATADiskDriveFW (CIM_SoftwareIdentity) Property name Property implementation SerialNumber A manufacturer-allocated number used to identify the software. e.g: 5RX25VNQ VersionString Drive firmware as reported from Win32_DiskDrive. FirmwareRevision e.g: HPF0 HP_SATADiskDriveFW 23-3-5 HP_SATAPortControllerPhysicalPackage HP_SATAPortControllerPhysicalPackage represents the overall physical package for the Host-attached IDE/ATA/SATA controllers.
HP Confidential Table 23-6 Class: HP_SATAPortControllerPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Tag Opaque Key Version Not Available in the current implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HP_SATAPortControllerPhysicalPackage 23-3-6 HP_SATADiskPhysicalPackage HP_SATADiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive.
HP Confidential Table 23-7 Class: HP_SATADiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation HotSwappable Not Available in this implementation. RemovalConditions 2 (Not Applicable) HP_SATADiskPhysicalPackage 23-3-7 HP_SATAStorageCollection HP_SATAStorageCollection represents a collection of Disk Drives that have been grouped together to report consolidated status.
HP Confidential Table 1-9 Class: HP_SATADiskLocation (HP_Location) Property name Property implementation Description String representing Disk location relative to the controller it is connected to. E.g: Standard ATA Disk Drive at ATA Channel 0,229ABF40 ElementName String representing Disk location relative to the controller it is connected to. E.
HP Confidential Table 1-10 Class: HP_SATAControllerLocation (HP_Location) Property name Property implementation HP_Location ElementLocationTag PCI DEVICE ID: 3A22 ElementLocationTagDesc 15(PCI) 23-3-10 HP_SATAPortControllerProduct HP_SATAPortControllerProduct represents the top-level marketing information for the Host-attached IDE/ATA/SATA controller.
HP Confidential Table 23-3 Class: HP_SATALogicalPort(CIM_LogicalPort) Property name Property implementation OperationalStatus Operational Status of a Controller Port. Possible Values are: 2 (OK) 6 (Error) 3 (Degraded) 0 (Unknown) 5 (Predictive Failure) CIM_ EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice SystemCreationClassName same value as property HP_WinComputerSystem.
HP Confidential Table 23-4 Class: HP_ISATAProtocolEndpoint (CIM_ProtocolEndpoint) Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) RequestedState 12 (Not Applicable) CIM_ServiceAccessPoint CreationClassName HP_ISATAProtocolEndpoint SystemCreationClassName same value as property HP_WinComputerSystem.CreationClassName SystemName same value as property HP_WinComputerSystem.
HP Confidential 23-3-14 HP_SATAPortControllerDriver HP_SATAPortControllerDriver represents properties of the storage driver used by the controller. Table 23-6 Class HP_SATAPortControllerDriver(HP_SoftwareIdentity) Property name Property implementation CIM_ManagedElement Caption PCI IDE Driver(for pciide.sys) NATIVE SATA Driver(for msahci.sys) ATAPI Driver(for atapi.sys) Description Standard IDE ATA/ATAPI controllers driver(for pciide.sys and atapi.sys) Standard SATA controllers driver(for msahci.
HP Confidential Table 23-7 Class HP_SATAPortControllerFW(HP_SoftwareIdentity) Property name Property implementation CIM_ManagedElement Caption e.
HP Confidential Table 23-8 Class HP_SATAPortControllerBIOS(HP_SoftwareIdentity) Property name Property implementation CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions Same as caption Classifications 6 (Firmware/BIOS) IsEntity False(always set to False) IdentityInfoType CIM:SoftwareFamily IdentityInfoValue HPQ: InstanceID Opaque key Manufacturer Standard IDE ATA/ATAPI controllers BIOS (for pciide.sys and atapi.
HP Confidential Table 23-11 Class: HP_SATAPortControllerPhysicalPackageSATAControllerLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HP_SATAPortControllerPhysicalPackage PhysicalLocation HP_SATAControllerLocation 23-3-20 HP_SATAPortControllerProductSATAPortControllerPhysica lPackage (Association) Table 23-12 Class: HP_SATAPortControllerProductSATAPortControllerPhysicalPackage (CIM_ProductPhysicalComponent) Property name Property implementation GroupComponent
HP Confidential 23-3-23 HP_WinComputerSystemSATAStorageExtent (Association) Table 23-15 Class: HP_WinComputerSystemSATAStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent HP_WinComputerSystem PartComponent HP_SATAStorageExtent 23-3-24 HP_WinComputerSystemSATADiskDrive (Association) Table 23-16 Class: HP_WinComputerSystemSATADiskDrive (CIM_SystemDevice) Property name Property implementation GroupComponent HP_WinComputerSystem PartComponent HP_SATADiskDrive 2
HP Confidential 23-3-27 HP_SATADiskPhysicalPackageSATADiskDrive (Association) Table 23-19 Class: HP_SATADiskPhysicalPackageSATADiskDrive (CIM_Realizes) Property name Property implementation Antecedent HP_SATADiskPhysicalPackage Dependent HP_SATADiskDrive 23-3-28 HP_SATADiskPhysicalPackageSATADiskLocation (Association) Table 23-20 Class: HP_SATADiskPhysicalPackageSATADiskLocation (CIM_PhysicalElementLocation) Property name Property implementation Element HP_SATADiskPhysicalPackage PhysicalLoca
HP Confidential 23-3-31 HP_SATALogicalPortISATAProtocolEndpoint (Association) Table 23-23 Class: HP_SATALogicalPortISATAProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent HP_SATALogicalPort Dependent HP_ISATAProtocolEndpoint 23-3-32 HP_SATAInitiatorTargetLogicalUnitPath The following class instance is created to represent the path from disk to controller.
HP Confidential 23-3-35 HP_SATAPortControllerFWSATAPortController (Association) Table 23-27 Class: HP_SATAPortControllerFWSATAPortController (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent HP_SATAPortControllerFW Dependent HP_SATAPortController ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) 23-3-36 HP_SATAPortControllerBIOSSATAPortController (Association) Table 23-28 Class: HP_SATAPortControllerBIOSSATAPortC
HP Confidential 23-4 Supported indications 23-4-1 New Disk Drive found Table 23-30 HP_SATADeviceIndication: New Disk Drive found Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A new disk drive was detected.
HP Confidential Table 23-30 HP_SATADeviceIndication: New Disk Drive found Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, .. ProviderVersion Provider version generating the indication in the format, ...
HP Confidential 23-4-2 Physical Drive Status Changed to unknown Table 23-31 HP_SATADeviceIndication: Disk Drive status unknown Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A Disk Drive status has changed to Unknown.
HP Confidential Table 23-31 HP_SATADeviceIndication: Disk Drive status unknown Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
HP Confidential Table 23-32 HP_SATADeviceIndication: Disk Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A Disk Drive status has changed to OK.
HP Confidential Table 23-32 HP_SATADeviceIndication: Disk Drive status OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other s
HP Confidential Table 23-33 HP_SATADeviceIndication: Disk Drive status Error Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 6 (Critical) IndicationTime Time of indication CIM_AlertIndication Description A Disk Drive status has changed to 'Error'.
HP Confidential Table 23-33 HP_SATADeviceIndication: Disk Drive status Error Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) ar
HP Confidential Table 23-34 HP_SATADeviceIndication: Disk Drive status Degraded Property name Property implementation PerceivedSeverity 3 (Degraded/Warning) IndicationTime Time of indication CIM_AlertIndication Description A Disk Drive status has changed to Degraded. AlertingManagedElement WBEM path of the HP_SATADiskDrive class AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 604 ProviderName HP SATA RecommendedActions Check status of physical drive.
HP Confidential Table 23-34 HP_SATADeviceIndication: Disk Drive status Degraded Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*)
HP Confidential Table 23-35 HP_SATADeviceIndication: Disk Drive status Predictive Failure Property name Property implementation PerceivedSeverity 3 (Degraded/Warning) IndicationTime Time of indication CIM_AlertIndication Description A Disk Drive status has changed to Predictive Failure.
HP Confidential Table 23-35 HP_SATADeviceIndication: Disk Drive status Predictive Failure Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.
HP Confidential Table 23-36 HP_SATADeviceIndication: Disk Drive is missing Property name Property implementation CIM_AlertIndication Description A Disk Drive disappeared from system. AlertingManagedElement WBEM path of the HP_SATADiskDrive class AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 613 ProviderName HP SATA RecommendedActions No action is recommended.
HP Confidential Table 23-36 HP_SATADeviceIndication: Disk Drive is missing Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class BladeSystems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.
24 BIOS Management 24-1 Overview The following profiles are implemented, and files are installed by this provider. Table 24-1 Overview 24-2 Implemented Profiles DMTF BIOS Management Profile (DSP1061) Provider Installation Files HPWmiBIOS.dll HPWmiBIOS.mof Use cases For use cases, see the DMTF BIOS Management (DSP1061). 24-3 Class implementations The following classes describe the BIOS Management implementation.
Table 24-2 Class: HP_BIOSAttribute Properties AttributeName A string identifying the structured element name for BIOS attribute using the format ":‖ CurrentValue An array of strings representing the current value or values of the BIOS Attribute. IsReadOnly This property specifies if the underlying system BIOS or BIOSService will not allow the Attribute to be modified. Since the Modifier methods are not implemented,Value is set to true for current version.
24-3-3 HP_BIOSComponent HP_BIOSComponent extends the class CIM_ConcreteComponent and associates instances of HP_BIOSElement and HP_BIOSAttribute. The following properties are implemented. Table 24-4 Class: HP_BIOSComponent Properties Property name Property implementation CIM_ConcreteComponent 24-3-4 GroupComponent Ref:HP_BIOSElement PartComponent Ref:HP_BIOSAttribute HP_SystemBIOS HP_SystemBIOS extends the class CIM_systemBIOS and associates HP_WinComputerSystem and HP_BIOSElement.
25 Support and other resources 25-1 Information to collect before contacting HP Be sure to have the following information available before you contact HP: Software product name Hardware product model number Operating system type and version Applicable error message Third-party hardware or software Technical support registration number (if applicable) 25-2 How to contact HP Use the following methods to contact HP technical support: In the United States, see the Customer Service / Contact HP United
When a security defect is found, HP has a well defined process that culminates with the publication of a security bulletin. The security bulletin provides you with a high level description of the problem and explains how to mitigate the security defect. 25-4 Subscription service HP recommends that you register your product at the Subscriber's Choice for Business website: http://www.hp.com/country/us/en/contact_us.
25-7 HP authorized resellers For the name of the nearest HP authorized reseller, see the following sources: In the United States, see the HP U.S. service locator website: http://www.hp.com/service_locator In other locations, see the Contact HP worldwide website: http://www.hp.com/go/assistance 25-8 New and changed information in this edition Chapter 2: In Table 2-5 Class: HP_PowerManagementService Properties, the property implementation value of the property Started is modified.
HP Insight Management WBEM Providers Release Notes available at: http://www.hp.com/go/wbem/docs HP Insight Management WBEM Providers Hardware Support Matrix available at: http://www.hp.com/go/wbem/docs HP Insight Management WBEM Providers SNMP Data Migration Guide available at: http://www.hp.com/go/wbem/docs HP Insight Management WBEM Providers Event Log Messages available at: http://www.hp.
HP Confidential 26 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback (docsfeedback@hp.com). Include the document title and part number, version number, or the URL when submitting your feedback.