HP Insight Management WBEM Providers 9.3 Release Notes

1 What's new in this release
The following features are supported in the current release of WBEM Providers:
Classifies cache state to reflect the operational status.
Supports Logical Unit Number (LUN) cache. The following two properties are added in the
Logical Drive page to support LUN caching:
LogicalVolumeType
RelatedLUN
The Memory Summary table in the Memory Information page is modified to include the
following properties:
Operating Voltage
Operating Speed
The following columns are added in the Board Details table in the Memory Information page:
Minimum Voltage
Ranks
Technology
For more information, see the online help available on the GUI, when you click on the ?
button.
Known issues and limitations
This section provides a list of known problems and limitations as known to HP at time of publication.
If workarounds are available, they are included.
Microsoft Teaming is not supported on Windows 2012
WBEM Providers 9.3 on Windows 2012 does not support Microsoft Teaming and as a result
does not display the network teams created in Windows 2012. Also, WBEM Network Providers
do not generate network teaming events on Windows 2012.
Severity: High
Corrective Action: None
Network connectivity lost during WBEM installation
WBEM Provider installation hangs inconsistently when installed using tools such as the HP
Rapid Deployment software. This issue is caused when WBEM Provider enters a non-operational
mode during installation due to certain memory race conditions.
Severity: High
Corrective Action: Cancel the installation manually and restart the server.
4 What's new in this release