HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-19 Class: HP_ProcessorElementLocation
Property name
Property implementation
HP_ProcessorElementLocation
Element
ref: HP_ProcessorChip
PhysicalLocation
ref: HP_ProcessorLocation
3-4 Supported indications
The following indications are implemented for ProLiant server platforms where available. CPU
indications are described in the following table.
3-4-1 Processor Failed
Table 1-20 HP_ProcessorHardwareIndication: Processor Failed
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
4 (Minor)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Processor has failed
AlertingManagedElement
WBEM path of the HP_ProcessorChip instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Processor
RecommendedActions
Replace the failed Processor.
SystemName
HP_ComputerSystem.SystemName
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Processor failed
EventCategory
2 (Processor)
ProbableCause
1 (Other)
ProbableCauseDescription
Processor has failed
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>