HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-34 HP_SATADeviceIndication: Disk Drive status Degraded
Property name
Property implementation
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_WinComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HP_DeviceIndication
DeviceModel
Physical Disk Model string
23-4-6 Physical Drive Status Changed to Predictive Failure
Table 1-35 HP_SATADeviceIndication: Disk Drive status Predictive Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Degraded/Warning)
IndicationTime
Time of indication
CIM_AlertIndication