HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-34 HP_TapeDriveDeviceIndication: Failed Drive Now Missing
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description
See HPWMITapeEventMetaData.mof
AlertingMangedElement
WBEM Path of HPSCSI_TapeDrive class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
508 (Failed drive now missing)
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP Tape
RecommendedActions
See HPWMITapeEventMetaData.mof
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
See HPWMITapeEventMetaData.mof
EventCategory
7 (Secondary Storage Device)
ProbableCause
73 (Element Missing)
ProbableCauseDescription
Missing tape drive that was Failed
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication