Table 2-38 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to Link Down
Property name
Property implementation
ProbableCauseDescription
FC HBA Port State Changed to Link Down
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
• For Windows 2008 R2: 103
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
BladeBay
HP_BladeCSLocation.LocationInformation[0]
BladeName
HP_ComputerSystem.Name
EnclosureName
HP_BladeEnclosureCS.Name
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
• 4 (System) for all other systems
RackName
Rack name, if one exists
RackUID
Rack Unique Identifier, if one exists
HWFirmwareVersion
Controller F/W version string
HWSerialNumber
Controller Serial Number
HWManufacturer
Name of Hardware Manufacturer