HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 2-37 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to OK
Property name
Property implementation
DevicePermanentNameFormat
PortWWN
DevicePermanentName
PortWWN
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
18-4-2 Fibre Channel Port status changed to Link Down
Table 2-38
Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to Link Down
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fibre channel HBA port has changed to a state of
link down
AlertingManagedElement
WBEM Path of HPFCHBA_DeviceIndication
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
6
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP Fibre Channel
RecommendedActions
1 Check the FC cabling to this port
2 Reinsert the FC GBIC if it has been unplugged
3 Replace FC cabling or the FC GBIC if failure continues
SystemName
HP_ComputerSystem.SystemName
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
FC HBA port in link down state
EventCategory
11 (I/O Adapter)
ProbableCause
5 (Connection Establishment Error)