HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-80 HPSCSI_DeviceIndication: Fan status change—Degraded
Property name
Property implementation
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Enclosure firmware version string
HWLogicalLocation
Enclosure Location string
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
17-4-20 Fan Status change - ERROR
Table 1-81 HPSCSI_DeviceIndication: Fan status change - ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fan has failed and there are not enough fans in the
fan subsystem to keep the enclosure cool.
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)