HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Enclosure firmware version string
HWLogicalLocation
Enclosure Location string
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
17-4-17 Temperature sensor Status change - Critical
Table 1-78 HPSCSI_DeviceIndication: Temperature sensor status change—Critical
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
6 (Critical)
IndicationTime
Time of indication
CIM_AlertIndication
Description The SCSI storage enclosure temperature is outside of
normal operating range, and could permanently
damage the system
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
25
ProviderName
HP SCSI
RecommendedActions Ensure that the fans are spinning and check the room
temperature
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication