HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-23 Class: HPSCSI_DriveCageLocation (HP_Location)
Property name
Property implementation
HP_Location
ElementLocationTag
Duplex Top, Duplex Bottom, Non Duplex
ElementLocationTagDesc
22 (Drive Cage)
LocationInformation[0] HBA Port identifier
Examples:
SCSI Port 1
SCSI Port 2
LocationInfoDesc[0]
0 (Hood Tag)
17-3-23 HPSCSI_HBALocation
HPSCSI_HBALocation represents a location string for the HBA.
Table 1-24 Class: HPSCSI_HBALocation (HP_Location)
Property name
Property implementation
CIM_ ManagedElement
ElementName Controller name and location (for example, SCSI
Controller Port 1 in Slot 4)
Caption Controller name and location
For example, SCSI Controller Port 1 in Slot 4
Description Controller name and location
For example, SCSI Controller Port 1 in Slot 4
CIM_Location
Name
Key
PhysicalPosition
Key
HP_Location
ElementLocationTag
PCI slot number
ElementLocationTagDesc
23 (Adapter)
LocationInformation[0] PCI Slot number
Examples:
3—PCI Slot 3
0—Embedded on MotherBoard
LocationInfoDesc[0]
3 (PCI Slot)