HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-4 Class: HPSCSI_DiskDrive (CIM_DiskDrive)
Property name
Property implementation
DriveHasMNPData
•
True—drive can report MNP Data
• False—drive does not report MNP Data
DriveInterface
1 (Parallel SCSI)
DrivePlacement
•
0 (Unknown)—drive placement cannot be
determined
•
1 (Internal)—drive is internal to host
•
2 (External)—drive is contained in external
enclosure
DriveRotationalSpeed
Speed in rpm
NegotiatedDataWidth
Bus width in bits
NegotiatedSpeed
Current bus speed in bits per second
HPSCSI_DiskDrive
SMARTSupport Indicates whether the disk supports the SMART feature
or not
Action
Indicates the status of the physical disk
17-3-4 HPSCSI_StorageExtent
HPSCSI_StorageExtent represents the consumable storage that is available on a disk drive. There is
one instance per disk drive.
Table 1-5 Class: HPSCSI_StorageExtent (CIM_StorageExtent)
Property name
Property implementation
CIM_ManagedElement
ElementName
Disk name (for example, SCSIBUS:1 SCSIID:0)
CIM_ManagedSystemElement
Name
Serial number of drive
OperationalStatus[0]
•
0 (Other)
•
2 (OK)
•
5 (Predictive Failure)
• 6 (ERROR)
StatusDescriptions
Description about the OperationalStatus
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)