Table 2-92 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
2-4-17 Enclosure Temperature sensor Status Changed to
Critical
Table 2-93 HPSAS_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is
reaching the maximum allowed temperature for normal
operation. A shutdown is imminent. Action is required
before loss of data occurs.
AlertingMangedElement
WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
309
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName
Name of the computer system generating the indication