HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 2-89 HPSAS_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
2-4-14 Enclosure Power Supply Status changed to
Redundant Degraded
Table 2-90 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply status has changed
to Degraded Redundancy.
AlertingMangedElement
WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
303
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.