Table 2-83 HPSAS_DeviceIndication: Drive status Predictive Failure
Property name
Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string
2-4-8 Physical Drive status Degraded – Drive
Authentication Failed
Table 2-84 HPSAS_DeviceIndication: Drive status Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity
3(Degraded)
IndicationTime
Time of indication
CIM_AlertIndication
Description Indicates that the physical drive was not able to be
authenticated and could not be validated to be a
genuine HP hard drive.
AlertingMangedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)