HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 2-79 HPSAS_DeviceIndication: Physical Drive status OK
Property name
Property implementation
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string
2-4-4 Physical Drive status ERROR
Table 2-80
HPSAS_DeviceIndication: Physical Drive status ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity Severity
For example, 5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A physical drive status has changed to Error.
AlertingMangedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
202
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive status Error
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)