HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
2-4-3 Physical Drive Status OK
Table 2-79 HPSAS_DeviceIndication: Physical Drive status OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity
2 (Informational)
IndicationTime
Time of indication
CIM_AlertIndication
Description A physical drive status has changed from non-OK to
OK.
AlertingMangedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
201
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical Drive Status is now OK
EventCategory
6 (Primary Storage)
ProbableCause
1 (Other)
ProbableCauseDescription
Physical Drive Status Changed to OK
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
OSType
•
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
• For Windows 2012: 113
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>