HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-129 HPSA_DeviceIndication: Controller Cache status—Not Configured
Property name
Property implementation
VariableNames
•
VariableNames[0]: FailureDescription
•
VariableNames[1]: CacheSizeTotal
• VariableNames[2]: CacheSerialNumber
VariableTypes
•
VariableTypes[0]: 1 (String)
•
VariableTypes[1]: 5 (uint16)
• VariableTypes[2]: 1 (String)
VariableValues
•
VariableValues[0]: Short Description of failure
•
VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
•
VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
HP_DeviceIndication
DeviceModel