HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-128 HPSA_DeviceIndication: Controller Cache statusFailed
Property name
Property implementation
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-4-21 Controller Cache Status Not Configured
Table 1-129 HPSA_DeviceIndication: Controller Cache statusNot Configured
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Smart Array Controller Cache Status has changed to
Not Configured.This may be caused by a configuration
change.
AlertingMangedElement
WBEM path to the HPSA_ArrayController class.