HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-116 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Property name
Property implementation
DeviceOperationalStatusPrevious Previous OperationStatus values for Storage Volume
•
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
•
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
15-4-9 Logical Drive Status Changed to Degraded -
multipath failure
Table 1-117 HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded - multipath failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Degraded)
IndicationTime
Time of indication
CIM_AlertIndication
Description A logical drive is in a degraded state. Multipath
support is Lost. Either cable is removed or not
configured.
AlertingMangedElement
WBEM path of the HPSA_StorageVolume class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
104
ProviderName
HP Smart Array
RecommendedActions
Check status of Logical drives. Degraded status may be
caused by multipath failure.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical drive in degraded state - multipath failure.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)