HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name
Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Logical drive number & RAID Level.
For example, LogicalDrive 1 (RAID 1+0).
HP_DeviceIndication
HPSA_StorageVolumeIndication
DeviceOperationalStatus Current OperationStatus values for Storage Volume
•
DeviceOperationalStatus[0]:
HPSA_StorageVolume.OperationalStatus[0]
•
DeviceOperationalStatus[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
DeviceOperationalStatusPrevious Previous OperationStatus values for Storage Volume
•
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
•
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
15-4-8 Logical Drive Status Changed to Degraded
Table 1-116
HPSA_StorageVolumeIndication: Logical Drive status changed to Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Degraded)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Logical Drive is in a degraded state. Device is still
servicing I/O but redundancy may be degraded or
lost.