HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-39 HPSA_DeviceIndication: Physical Drive status changed to OK
Property name
Property implementation
HWPhysicalLocation
Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer
HP
HWSerialNumber
Physical Disk Serial Number
HP_DeviceIndication
DeviceModel
Physical Disk Model string
15-4-2 Physical Drive Status Changed to ERROR
Table 1-40 HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Physical Drive status has changed to ERROR status.
AlertingMangedElement
WBEM path of the HPSA_DiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
202
ProviderName
HP Smart Array
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical Drive status ERROR.
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication