HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

15-3-17 HPSA_PrimordialPool
HPSA_PrimordialPool represents the total raw storage managed by the array controller. There is one
instance per array system.
Table 1-18 Class: HPSA_PrimordialPool (CIM_StoragePool)
Property name
Property implementation
CIM_ManagedElement
ElementName Controller name and location: pool identifier (for
example, Smart Array in Slot 3: Primordial Pool)
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
InstanceID
Opaque key
PoolID
Controller serial number
Primordial
Always set to TRUE
RemainingManagedSpace Remaining raw space on controller. This is calculated
by summing the remaining space on all drives attached
to the controller.
TotalManagedSpace Total raw space available to controller. This is
calculated by summing the total space on all drives
connected to this controller.
HPSA_PrimordialPool
15-3-18 HPSA_StoragePool
HPSA_StoragePool represents any concrete storage pools created on an array controller. There is one
instance per RAID set.
Table 1-19 Class: HPSA_StoragePool (CIM_StoragePool)
Property name
Property implementation
CIM_ManagedElement
ElementName Controller name and location: pool identifier (for
example, Smart Array in Slot 3: Array 0)
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
InstanceID
Opaque key
PoolID Controller serial number:<n>, where <n> is the array
number as supplied from API