HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-34 Optional HP_AlertIndication: Ethernet Team Member Added
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description An Ethernet Team member has been added to the
team, further information is available in the variable
information of this indication. This is an optional
indication that can be disabled through the Ethernet
Event Provider settings.
AlertingManagedElement WBEM path of the Ethernet Team
(HP_WinEthRedundancySet) reporting lost redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
2 (Communications Alert)
Event Id
7
ProviderName
HP Ethernet
RecommendedActions[]
None
SystemCreationClassName CreationClassName of the computer system generating
the indication
SystemName
Name of the computer system generating the indication
HP_AlertIndication
Summary An Ethernet Team Member has been added to the
team.
EventCategory
9 (Network Device)
EventSubCategory
12 (Ethernet Team)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>