Table 1-28 HP_AlertIndication: Ethernet Team Full Redundancy Restored
Property name
Property implementation
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
13-4-5 Network Interface Connectivity Lost
Table 1-29 HP_AlterIndication: Network Interface Connectivity Lost
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
6 (Critical)
IndicationTime
Time of indication
CIM_AlertIndication
Description If the Network Interface is an Ethernet Port, the Ethernet
Port has transitioned from OK to Error. If the Network
Interface is an Ethernet Team, the Ethernet Team has
transitioned from Fully Redundant, Degraded
Redundancy or Redundancy Lost to Overall Failure,
due to a failed team member.
AlertingManagedElement WBEM path of the Ethernet Port (HP_WinEthernetPort)
or Ethernet Team (HP_WinEthRedundancySet) reporting
lost connectivity.