HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-26 HP_AlertIndication: Ethernet Team Redundancy Increased
Property name
Property implementation
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
13-4-3 Ethernet Team Redundancy Decreased
Table 1-27 HP_AlertIndication: Ethernet Team Redundancy Decreased
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Degraded/Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description The Ethernet Team has transitioned from Fully
Redundant or Degraded Redundancy to Degraded
Redundancy due to a failed or degraded team
member.
AlertingManagedElement WBEM path of the Ethernet Team
(HP_WinEthRedundancySet) reporting decreased
redundancy
AlertingElementFormat
2 (CIMObjectPath)
AlertType
2 (Communications Alert)
Event Id
4
ProviderName
HP Ethernet
RecommendedActions[] View the Ethernet and Ethernet Team Member status in
the HP Network Configuration Utility (NCU).
View the System Event Log for additional information.