HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-28 HP_MemoryHardwareIndication: Memory Board Error
Property name
Property implementation
HP_MemoryHardwareIndication
AlertType
5 (Device Alert)
7-5-3 Memory Redundancy Degraded
Table 1-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
IndicationTime
Time of indication
CIM_ProcessIndication
CIM_AlertIndication
Description The Advanced Memory Protection (AMP) system is
operating with degraded redundancy. The targeted
configuration has degraded or is operating with
memory modules that have failed or predicted to fail.
(TargetConfiguration/CurrentConfiguration), where
TargetConfiguration is
HP_MemoryRedundancySet.TargetConfiguration.
AlertingManagedElement WBEM Path of HP_MemoryBoard instance
representing the memory board
AlertingElementFormat
2 (CIMObjectPath)
PerceivedSeverity
5 (Major)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Advanced Memory Protection Degraded
RecommendedActions Check the Advanced Memory Protection configuration
and replace the memory board and memory modules
as necessary. Repair appropriate IML log messages
after memory is replaced.
EventID
3
EventTime Time of the event or time of the indication if event time
unknown
SystemCreationClassName
HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.SystemName
ProviderName
HP Memory
HP_AlertIndication