HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-9 Class: HP_MemoryCollection
Property name
Property implementation
CIM_SystemSpecificCollection
InstanceID
HPQ:HP_MemoryCollection:001
HP_GroupSystemSpecificCollection
GroupOperationalStatus Enumerator indicating the group operational status of
the memory collection. The status is determined as
follows:
•
If an instance of HP_MemoryRedundancySet exists,
GroupOperationalStatus[0] is determined from the
property
HP_MemoryRedundancySet.RedundancyStatus.
•
If no instance of HP_MemoryRedundancySet exists,
GroupOperationalStatus[0] is determined by the
‘worst-of’ algorithm for physical memory boards
and memory modules.
For details, see the Memory Collection Status.
GroupStatusDescriptions GroupStatusDescriptions[0] contains descriptive text
per GroupOperationalStatus[0]:
•
Memory collection status: OK
•
Memory collection status: Degraded
• Memory collection status: Unknown
HP_MemoryCollection
Table 1-10 Memory Collection Status
RedundancyStatus
from
HP_MemoryRedundanc
ySet
‘worst’
OperationalStatus[0],
HP_MemoryBoard
‘worst’
OperationalStatus[0],
HP_MemoryModule
GroupOperationalStatus
[0]
2 (Fully Redundant)
—
—
2 (OK)
3 (Degraded Redundancy)
—
—
3 (Degraded)
—
2 (OK)
2 (OK)
2 (OK)
—
2 (OK)
3 (Degraded)
3 (Degraded)
—
2 (OK)
0 (Unknown)
0 (Unknown)
—
3 (Degraded)
2 (OK)
3 (Degraded)
—
3 (Degraded)
3 (Degraded)
3 (Degraded)
—
3 (Degraded)
0 (Unknown)
3 (Degraded)
—
0 (Unknown)
2 (OK)
0 (Unknown)
—
0 (Unknown)
3 (Degraded)
3 (Degraded)
—
0 (Unknown)
0 (Unknown)
0 (Unknown)