HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-26 HP_SensorHardwareIndication: Fan Redundancy Gained
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fault tolerant fan has been added to a cooling
redundancy set. (RedundancySetCaption), where
RedundancySetCaption is
HP_WinCoolingRedundancySet.Caption of the
redundancy set with an added fan
AlertingManagedElement WBEM Path of HP_WinCoolingRedundancySet
instance representing the cooling redundancy set with
an added fan
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
7
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Cooling redundancy gained
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Cooling Redundancy has been Gained
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
• For Windows 2012: 113