HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-25 HP_SensorHardwareIndication: Fan Redundancy Lost
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
4 (Minor)
IndicationTime
Time of indication
CIM_AlertIndication
Description Cooling redundancy has been lost.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinCoolingRedundancySet.Caption
for the redundancy set that lost redundancy.
AlertingManagedElement WBEM path of the HP_WinCoolingRedundancySet
instance representing the redundancy set where
redundancy was lost.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
6
ProviderName
HP Cooling
RecommendedActions
Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Cooling redundancy lost.
EventCategory
23 (System Cooling)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription
Cooling Redundancy has been Lost.
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113