HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet

Table 1-21 HP_SensorHardwareIndication: Fan Failed
Property name
Property implementation
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-4 Fan Degraded
Table 1-22 Hp_SensorHardwareIndication: Fan Repaired
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fan has been degraded. (FanCaption), where
FanCaption is the HP_WinFan.Caption for the fan that
has been degraded.
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the degraded Fan.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
9
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Fan Degraded.
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Fan Degraded due to Single Rotor Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication