HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-20 HP_SensorHardwareIndication: Fan Inserted
Property name
Property implementation
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-3 Fan Failed
Table 1-21
HP_SensorHardwareIndication: Fan Failed
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fan has failed. (FanCaption), where FanCaption is the
HP_WinFan.Caption for the fan that has failed
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the failed fan
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
3
ProviderName
HP Cooling
RecommendedActions
Check the failed fan and replace if necessary.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Fan failed
EventCategory
23 (System Cooling)
ProbableCause
94 (Fan Failure)
ProbableCauseDescription
Fan Failed
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>