HP Insight Management WBEM Providers 9.3 for Microsoft Windows Data Sheet
Table 1-19 HP_SensorHardwareIndication: Fan Removed
Property name
Property implementation
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-2 Fan Inserted
Table 1-20
HP_SensorHardwareIndication: Fan Inserted
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fan has been inserted. (FanCaption), where
FanCaption is the HP_WinFan.Caption for the fan that
has been inserted
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the inserted fan
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
2
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Fan Inserted
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Fan Inserted