HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet

Table 2-37 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to OK
Property name
Property implementation
HWManufacturer
Name of Hardware Manufacturer
DevicePermanentNameFormat
PortWWN
DevicePermanentName
PortWWN
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
18-4-2 Fibre Channel Port status changed to Link Down
Table 2-38 Class: HPFCHBA_DeviceIndication: Fibre Channel Port status changed to Link Down
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fibre channel HBA port has changed to a state of
link down
AlertingManagedElement
WBEM Path of HPFCHBA_DeviceIndication
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
6
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP Fibre Channel
RecommendedActions
1 Check the FC cabling to this port
2 Reinsert the FC GBIC if it has been unplugged
3 Replace FC cabling or the FC GBIC if failure continues
SystemName
HP_ComputerSystem.SystemName
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
FC HBA port in link down state
EventCategory
11 (I/O Adapter)