HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet
Table 1-81 HPSCSI_DeviceIndication: Fan status change - ERROR
Property name
Property implementation
IndicationTime
Time of indication
CIM_AlertIndication
Description A fan has failed and there are not enough fans in the
fan subsystem to keep the enclosure cool.
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
16
ProviderName
HP SCSI
RecommendedActions Check your fan subsystem as soon as possible.
Continued operation can cause failure of the drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
SCSI Storage enclosure fan is failed
EventCategory
24 (Primary Storage Cooling)
ProbableCause
94 (Fan Failure)
ProbableCauseDescription
Fan Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
• For Windows 2012: 113
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication