HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet

Table 1-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description This SCSI Storage enclosure power supply was
redundant but due to a failure is not longer redundant
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
22
ProviderName
HP SCSI
RecommendedActions
Replace failed or missing power supply module
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary SCSI Storage Enclosure operating with no Redundant
Power Supply
EventCategory
17 (Primary Storage Power)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
Redundant
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>