HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet

Table 1-68 HPSCSI_DeviceIndication: Physical Drive status - Missing was Predictive Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description A physical drive that was located in the system and
had a status of Predictive Failure has been remove
AlertingMangedElement
WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
12
ProviderName
HP SCSI
RecommendedActions
Check for this disk to have been removed
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive missing was predictive failure
EventCategory
6 (Primary Storage)
ProbableCause
73 (Element Missing)
ProbableCauseDescription
Missing Physical Drive was Predictive Failure.
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
For Windows 2012: 113
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication