HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet
Table 2-82 HPSAS_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name
Property implementation
IndicationIdentifier
GUID string generated at the time of indication
PreceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Predictive
Failure.
AlertingMangedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
204
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
Replace drive immediately to avoid loss of data.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Physical drive predictive failure
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
ProbableCauseDescription
Physical Drive Predictive Failure
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
• For Windows 2012: 113
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication