HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet
Table 2-23 Class: HPSAS_StorageCapabilities (CIM_StorageCapabilities)
Property name
Property implementation
CIM_ManagedElement
ElementName
•
For Primodial Pools
Controller name and location, for example, HP 8
INT Port SAS/SATA HBA in Slot 3 for internal
•
For Concrete Pools
Controller name and location:Array identifier, for
example, HP 8 INT Port SAS/SATA HBA in Slot 3:
Storage Pool for internal
CIM_Capabilities
InstanceID
Opaque key
CIM_StorageCapabilities
DataRedundancyDefault
•
0 (When Pool is NonRAID)
•
1 (When number of drives = 1)
•
2 (When number of drives > 1) For example, Pool
can be configured for redundancy.
DataRedundancyMax
•
0 (When Pool is NonRAID)
•
1 (When number of drives = 1)
•
2 (When number of drives > 1) For example, Pool
can be configured for redundancy.
DataRedundancyMin
•
0 (When Pool is NonRAID)
• 1 (No single point of failure RAID)
DeltaReservationDefault
0
DeltaReservationMax
0
DeltaReservationMin
0
ElementType
5 (Storage Pool)
NoSinglePointOfFailure
•
True—When number of drives > 1 (For example,
Pool can be configured for redundancy.)
•
False—When number of drives = 1 or Pool is
NonRAID
NoSinglePointOfFailureDefault
•
True—When number of drives > 1 (For example,
Pool can be configured for redundancy.)
•
False—When number of drives = 1 or Pool is
NonRAID
PackageRedundancyDefault
•
0 (When Pool is NonRAID)
•
1 (When number of drives = 1)
• 2 (When number of drives > 1)