HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet
Table 1-133 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductM
odel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
15-4-26 Enclosure Temperature sensor Status Changed
to Critical
Table 1-134 HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description Temperature sensor Status changed to a status of
Critical. Enclosure temperature is reaching maximum
allowed temperature for normal operation, shutdown is
imminent. Action is required before loss of data occurs.
AlertingMangedElement
WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)