HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet
Table 1-129 HPSA_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
Description A Storage Enclosure Power Subsystem status has
changed to non-redundant
AlertingMangedElement
WBEM path of the HPSA_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
301
ProviderName
HP Smart Array
RecommendedActions Check status of all enclosure power supplies. Problem
may be caused by a failed power supply.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Power Supply Status Non-Redundant.
EventCategory
17 (Primary Storage Power)
ProbableCause
89 (Power Supply Failure)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
• For Windows 2012: 113
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication