HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet

Table 1-127 HPSA_DeviceIndication: Controller Cache statusTemporarily Disabled
Property name
Property implementation
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-4-20 Controller Cache Status - Permanently
Disabled
Table 1-128 HPSA_DeviceIndication: Controller Cache statusPermanently Disabled
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description Array Controller Cache Status is set to a status of
Permanently Disabled. Controller has detected a
problem with the cache and has disabled the cache
permanently.
AlertingMangedElement
WBEM path to the HPSA_ArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
11
ProviderName
HP Smart Array
RecommendedActions
Check Cache controller error code. Run diagnostics.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Array Controller Cache Status is Permanently Disabled.