HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet
Table 1-124 HPSA_DeviceIndication: Controller Battery status changed to not fully charged
Property name
Property implementation
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-4-17 Controller Battery Status Changed to FAILED
Table 1-125
HPSA_DeviceIndication: Controller Battery status changed to Failed
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
Controller Battery Status set to a status of Failed.
AlertingMangedElement
WBEM path to the HPSA_ArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
8
ProviderName
HP Smart Array
RecommendedActions
Check battery connection - replace if necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Controller Battery Status set to Failed.
EventCategory
6 (Primary Storage)
ProbableCause
92 (battery failure)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication