HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet
Table 1-122 HPSA_DeviceIndication: Controller Redundancy has been restored
Property name
Property implementation
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-4-15 Controller Battery Status Changed to OK
Table 1-123
HPSA_DeviceIndication: Controller Battery status changed to OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (info)
IndicationTime
Time of indication
CIM_AlertIndication
Description Array Controller Battery Status has changed to a status
of OK.
AlertingMangedElement
WBEM path to the HPSA_ArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
6