HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet

Table 1-119 HPSA_DeviceIndication: Controller status changed to ERROR
Property name
Property implementation
HP_HardwareIndication
HWFirmwareVersion
Array Controller firmware version string
HWLogicalLocation Array Controller Location string
For example, Smart Array P600 in Slot 5
HWManufacturer
Array Controller Manufacturer string
HWSerialNumber
Array Controller Serial Number
HP_DeviceIndication
DeviceModel
Array Controller Model string
15-4-12 Controller Redundancy state has been set to
Active
Table 1-120 HPSA_DeviceIndication: Controller Redundancy state has been set to ACTIVE
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Smart Array controller redundancy state has
changed from Standby to Active.
AlertingMangedElement
WBEM path to the HPSA_ArrayController class.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
3
ProviderName
HP Smart Array
RecommendedActions Check status of all controllers. A controller may have
failed to cause this controller to become active.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Controller Redundancy State has been set to Active