HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet

Table 1-114 HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name
Property implementation
DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
15-4-7 Logical Drive Status Changed to ERROR
Table 1-115 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Logical Drive Status has changed to Error .
AlertingMangedElement
WBEM path of the HPSA_StorageVolume class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
102
ProviderName
HP Smart Array
RecommendedActions
Check for failed or removed physical drives.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Logical Drive Status error
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication