HP Insight Management WBEM Providers 9.2.5 for Microsoft® Windows® Data Sheet
Contents 137
5-4-5 Fan Repaired
Table 1-23 Hp_SensorHardwareIndication: Fan Repaired
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime
Time of indication
CIM_AlertIndication
Description A fan has been repaired. The fan is now operating
properly. (FanCaption), where FanCaption is the
HP_WinFan.Caption for the fan that has been repaired
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the failed fan
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
4
ProviderName
HP Cooling
RecommendedActions
No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName
HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Fan Repaired.
EventCategory
23 (System Cooling)
ProbableCause
1 (Other)
ProbableCauseDescription
Fan Repaired
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2003 32-bit: 69
•
For Windows 2003 64-bit: 70
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
• For Windows 2012: 113